CSLB # 1054136 <br />PHONE 800.737.9892 <br />NEXT DOOR HOME CONST. <br />9800D TOPANGA CANYON BLVD <br />CHATSWORTH,CA 91311 <br />CONTRACTOR: <br />RESIDENCE: <br />ERIC CHRISTENSEN <br />2115 N GREENBRIER S, <br /> SANTA ANA, CA 92706 <br />APN #: 00111204 <br />SHEET:2.1 <br />REV:3/17/2023 <br />WEATHER RESISTANT PLASTIC <br />PLACARD PLACEMENT: MAIN PANEL <br />(COVER) <br />POWER TO THIS BUILDING IS ALSO <br />SUPPLIED FROM THE FOLLOWING <br />SOURCES WITH DISCONNECTS AS SHOWN <br />CAUTION: <br />SIGNAGE <br />2115 N GREENBRIER S, <br /> SANTA ANA, CA 92706 <br />SIGNAGE <br />PHOTOVOLTAIC SYSTEM <br />EQUIPPED WITH RAPID SHUTDOWN <br />LABEL LOCATION: <br />WEATHER RESISTANT MATERIAL, DURABLE PLAQUE, UL969 AS STANDARD TO WEATHER RATING (UL <br />LISTING OF MARKINGS NOT REQUIRED), MIN 3 8" LETTER HEIGHT ARIAL OR SIMILAR FONT NON-BOLD, <br />PLACED WITHIN THE MAIN SERVICE DISCONNECT, PLACED ON THE OUTSIDE OF THE COVER WHEN <br />DISCONNECT IS OPERABLE WITH SERVICE PANEL CLOSED. (PER CODE: CEC690.12, 690.56(C)) <br />ADHESIVE FASTENED SIGNS: <br />· THE LABEL SHALL BE SUITABLE FOR THE <br /> ENVIRONMENT WHERE IT IS INSTALLED. <br />· WHERE REQUIRED ELSEWHERE IN THIS CODE, <br /> ALL FIELD APPLIED LABELS, WARNINGS, AND <br /> MARKINGS SHOULD COMPLY WITH ANSI Z535.4 <br /> [NEC 110.21(B) FIELD MARKING]. <br />· ADHESIVE FASTENED SIGNS MAY BE <br /> ACCEPTABLE IF PROPERLY ADHERED. VINYL <br /> SIGNS SHALL BE WEATHER RESISTANT [IFC <br /> 605.11.1.3] <br />SIGNAGE REQUIREMENTS: <br />· RED BACKGROUND <br />· WHITE LETTERING <br />· MINIMUM 3/8" LETTER HEIGHT <br />· ALL CAPITAL LETTERS <br />· ARIAL OR SIMILAR FONT, <br /> NON-BOLD <br />· REFLECTIVE WEATHER <br /> RESISTANT MATERIAL SUITABLE <br /> FOR THE ENVIRONMENT <br /> (DURABLE ADHESIVE MATERIALS <br /> MUST MEET THIS REQUIREMENT) <br />LABEL LOCATION: <br />INVERTER, JUNCTION BOXES (ROOF), AC DISCONNECT <br />(PER CODE: CEC690.13 & CEC 690.13) <br />LABEL LOCATION: <br />INVERTER, JUNCTION BOXES (ROOF), AC DISCONNECT <br />(PER CODE: CEC690.13 & CEC 690.13) <br />WARNING <br />INVERTER OUTPUT CONNECTION DO NOT <br />RELOCATE THIS OVERCURRENT DEVICE <br />CAUTION: SOLAR ELECTRIC <br />SYSTEM CONNECTED <br />CAUTION: SOLAR CIRCUIT <br /> WARNING DUAL POWER SOURCE <br />SECOND SOURCE IS PHOTOVOLTAIC SYSTEM <br />! <br />WARNING: PHOTOVOLTAIC <br />POWER SOURCE <br />WARNING <br />ELECTRIC SHOCK HAZARD <br />DO NOT TOUCH TERMINALS <br />TERMINALS ON BOTH LINE AND <br />LOAD SIDES MAY BE ENERGIZED <br />IN THE OPEN POSITION <br />WARNING! <br />WARNING - Electric Shock Hazard <br />No user serviceable parts inside <br />Contact authorized service provider for assistance <br />! <br />AC SYSTEM DISCONNECT <br />FOR UTILITY OPERATION <br />LABEL LOCATION: <br />UTILITY DISCONNECT <br />LABEL LOCATION: <br />DC DISCONNECT, INVERTER <br />(PER CODE: CEC690.53) <br />LABEL LOCATION: <br />DC DISCONNECT, INVERTER <br />(PER CODE: CEC690.53) <br />PHOTOVOLTAIC SYSTEM AC DISCONNECT <br />RATED AC OPERATING CURRENT 29.04 AMPS <br />AC NOMINAL OPERATING VOLTAGE 240 VOLTS <br />SOLAR PV SYSTEM <br />EQUIPPED WITH RAPID <br />SHUTDOWN <br />TURN RAPID <br />SHUTDOWN <br />SWITCH TO THE <br />"OFF" POSITION TO <br />SHUTDOWN PV <br />SYSTEM AND <br />REDUCE <br />SHOCK HAZARD <br />IN THE ARRAY <br />SOLAR <br />ELECTRIC <br />PV PANELS <br />RAPID SHUTDOWN SWITCH <br />FOR SOLAR PV SYSTEM <br />LABEL LOCATION: <br />RAPID SHUTDOWN OR ON INVERTER IS RSD IS <br />INTEGRATED <br />CEC 690.56(C)(3) <br />LABEL LOCATION: <br />SERVICE DISCONNECTING MEANS <br />(PER CODE: CEC 690.56(C)(1)(A) <br />LABEL LOCATION: <br />PER CEC 705.12(B)(2)(3)(B) <br />[OR (C) IF PANELBOARD IS RATED NOT LESS THAN SUM OF AMPERE <br />RATINGS OF ALL OVERCURRENT DEVICES SUPPLYING IT] <br />LABEL LOCATION: <br />WEATHER RESISTANT MATERIAL, DURABLE ADHESIVE, UL969 AS STANDARD <br />TO WEATHER RATING (UL LISTING OF MARKINGS NOT REQUIRED), MIN 3 <br />8" LETTER HEIGHT ARIAL OR SIMILAR FONT NON-BOLD, PLACED WITHIN THE <br />MAIN SERVICE DISCONNECT, PLACED ON THE OUTSIDE OF THE COVER WHEN <br />DISCONNECT IS OPERABLE WITH SERVICE PANEL CLOSED. (PER CODE: <br />CEC690.15, 690.13(B)) <br />LABEL LOCATION: <br />MARKINGS PLACED ON ALL INTERIOR AND EXTERIOR DC/AC CONDUIT, RACEWAYS, <br />ENCLOSURES, AND CABLE ASSEMBLIES AT LEAST EVERY 1O FT, AT TURNS AND <br />ABOVE/BELOW PENETRATIONS AND ALL COMBINER/JUCTION BOXES. <br />LABEL LOCATION: <br />POINT OF INTERCONNECTION <br />(PER CODE: CEC 705.12(B)(3-4)) <br />DC VOLTAGE IS ALWAYS PRESENT <br />WHEN SOLAR MODULES ARE <br />EXPOSED TO SUNLIGHT <br />LABEL LOCATION: <br />DC DISCONNECT, INVERTER <br />(PER CODE: CEC 690.13(B)) <br />[To be used when inverter is ungrounded] <br />ELECTRIC SHOCK HAZARD <br />DO NOT TOUCH TERMINALS <br />TERMINALS ON BOTH LINE AND <br />LOAD SIDES MAY BE ENERGIZED <br />IN THE OPEN POSITION <br />LABEL LOCATION: <br />AC DISCONNECT, POINT OF <br />INTERCONNECTION <br />(PER CODE: CEC 690.53) <br /> SOLAR ARRAY <br />RATED MAXIMUM POWER- . <br />POINT CURRENT (Imp) . <br />RATED MAXIMUM POWER- . <br />POINT VOLTAGE (Vmp) . <br />MAXIMUM SYSTEM . <br />VOLTAGE (VOC) . <br />MAXIMUM CIRCUIT . <br />CURRENT (Isc) . <br />A <br />V <br />V <br />A <br />41.34 <br />13.17 <br />INVERTER <br />34.16 <br />13.80 <br />(E) MAIN PANEL <br />(N) IQ COMBINER BOX <br />(N) AC DISCONNECT <br />2115 N Greenbrier <br />St05/31/23