My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2329 N Fairmont Ave - Plan
PBA
>
Building
>
ProjectDox
>
F
>
Fairmont Ave
>
2329 N Fairmont Ave
>
2329 N Fairmont Ave - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/1/2025 12:02:20 PM
Creation date
6/1/2025 12:01:50 PM
Metadata
Fields
Template:
Plan
Permit Number
20182176
101118370
Full Address
2329 N Fairmont Ave
Document Relationships
101118370 - Permit
(Permit - Plan)
Path:
\Building\Permits\F\Fairmont Ave\2329 N Fairmont Ave
20182176 - Permit
(Permit - Plan)
Path:
\Building\Permits\F\Fairmont Ave\2329 N Fairmont Ave
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
28
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
Vertical Load Resisting System Design <br />Roof Framing Rafters <br />Snow Load Fully Exposed <br />pg=0 psf Ct =1.1 <br />Ce =0.9 Is =1.0 <br />pf = 0 psf <br />pfmin. = 0.0 psf <br />ps = 0 psf Conservatively (Cs=1)0 plf <br />Max Length, L =8.0 ft (Rafter maximum Allowable Horizontal Span) <br />Tributary Width, WT =24 in <br />Dr =10 psf 20 plf <br />PvDL =3 psf 18 plf <br />Load Case: DL+0.75(0.6W+S) <br /> 0.75(Pnet+Ps)+ Ppvcos(θ)+PDL=41 plf <br />Mdown=330 lb-ft <br />Mallowable = Sx x Fb' (wind)=456 lb-ft >330 lb-ft OK <br />Load Case: DL+S <br /> Ps+ Ppvcos(θ)+PDL=38 plf <br />Mdown=304 lb-ft <br />Mallowable = Sx x Fb' (wind)=456 lb-ft >304 lb-ft OK <br />Load Case: DL+0.6W <br /> Pnet+ Ppvcos(θ)+PDL=42.4 plf <br />Max Moment, Mu=339 lb-ft <br />Mallowable = Sx x Fb' (wind)=634 lb-ft >339 lb-ft OK <br />Pv max Shear=110.1 lbs <br />Shear, Vu=wL/2+Pv Point Load =262 lbs <br />Max Shear, Vu=wL/2+Pv Point Load =262 lb <br />Member Capacity <br />DF-L No.2 <br />2X4 CL CF Ci Cr KF φ λ <br />Fb =900 psi 1.0 1.5 1.0 1.15 2.54 0.85 0.8 1553 psi <br />Fv =180 psi N/A N/A 1.0 N/A 2.88 0.75 0.8 180 psi <br />E =1600000 psi N/A N/A 1.0 N/A N/A N/A N/A 1600000 psi <br />Emin =580000 psi N/A N/A 1.0 N/A 1.76 0.85 N/A 580000 psi <br />Depth, d =3.5 in <br />Width, b =1.5 in <br />Cross-Sectonal Area, A =5.25 in2 <br />Moment of Inertia, Ixx =5.35938 in4 <br />Section Modulus, Sxx =3.0625 in3 <br />Allowable Moment, Mall = Fb'Sxx =396.2 lb-ft DCR=Mu/Mall =0.73 < 1 Satisfactory <br />Allowable Shear, Vall = 2/3Fv'A =630.0 lb DCR=Vu/Vall =0.42 < 1 Satisfactory <br />Design Value Adjusted Value <br />projects@evengineersnet.com <br />http://www.evengineersnet.com <br />2329 N Fairmont Ave - <br />201821764/3/2024
The URL can be used to link to this page
Your browser does not support the video tag.