Laserfiche WebLink
(N) ENPHASE <br />IQ BATTERY-5P-1P-NA <br />[240] <br />RO <br />O <br />F <br /> <br />T <br />O <br />P <br />GR <br />O <br />U <br />N <br />D <br /> <br />L <br />E <br />V <br />E <br />L <br /> <br />- <br />HO <br />U <br />S <br />E <br /> <br />E <br />X <br />T <br />E <br />R <br />I <br />O <br />R <br />20A <br />20A <br />N <br />15A <br />2 <br />(N) 125A ENPHASE <br />X-IQ-AM1-240-5/5C <br />COMBINER BOX WITH <br />ENPHASE IQ ENVOY <br />COMM. GATEWAY <br />4 <br />PV WIRES NEEDS TO MAINTAIN A 1’ <br />MINIMUM SEPARATION WHEN THERE <br />IS PV OUTSIDE OF THE MICROGRID <br />TO AVOID RISK OF CROSSTALKING <br />BETWEEN ENVOYS. <br />1. ENVOY MUST BE NO FARTHER THAN 150' FROM THE <br />LAST MICROINVERTER. <br />2. MAX DISTANCE BETWEEN ENSEMBLE DEVICES IS 50' <br />LINE OF SIGHT WITH NO OBSTRUCTIONS. <br />12 <br />PV CIRCUIT 1: 12 MODULES/PARALLEL <br />12 1 <br />(N) JUNCTION BOX <br />WITH IRREVERSIBLE <br />GROUND SPLICE <br />(N) 12 CANADIAN SOLAR CS6R- 400MS-HL [BLK] (400W) MODULES <br /> WITH AN ENPHASE IQ8PLUS-72-2-US [240V] MICRO-INVERTER <br />ATTACHED TO THE BACK OF EVERY MODULE. <br />NOTE: IN BETWEEN EACH ARRAY THE EMT IS USED AS THE <br />GROUNDING / BONDING, GROUND CLAMPS ARE AT EACH <br />END OF THE EMT CONDUIT WITH THE WIRE THEN FREE <br />AIR'D TO THE GROUND CLAMP ON THE RACKING RAIL <br />(N) VISIBLE <br />LOCKABLE <br />2 POLE 60A <br />'KNIFE' AC <br />DISCONNECT <br />(SQUARE D DU221RB) <br />4 <br />3 <br />BACKFEED <br />BREAKER <br />M <br />POINT OF <br />DELIVERY AND <br />INTERCONNECTION <br />200A <br />EXISTING <br />240V/200A <br />METER MAIN COMBO <br />SINGLE PHASE <br />(E) GROUNDING <br />ELECTRODE OR <br />(UFER) <br />N <br />CT CABLE <br />(N) VISIBLE <br />LOCKABLE <br />2 POLE 60A 'KNIFE' <br />AC DISCONNECT <br />SQUARE D DU222RB <br />3 <br />100A <br />40A <br />N <br />EXISTING TRENCHING <br />NEW <br />240V/125A <br />SUB SERVICE PANEL <br />SINGLE PHASE <br />100A <br />SHEET <br />CONTRACTOR <br />ILUM SOLAR <br /> 2329 FAIRMONT AVE, <br /> SANTA ANA, <br /> CA 92706 <br /> APN:00310010 <br /> DATE:3/13/2024 <br />WATERSON <br />RESIDENCE <br />License#:1092865, C-46 <br />ADDRESS: <br />4135 NORTHGATE BLVD <br />SUITE 9, SACRAMENTO, <br />CA 95834, USA <br />DESIGNER: OHD <br />E-1 <br />SUB SERVICE PANEL <br />240/120V 1Ø, 3W <br />MAIN BUSS: 125A <br />MAX BREAKER SIZE: <br />(125A X 1.2) - 100A = 50A <br />NOTE : CT CABLES SHOULD NOT RUN <br />THROUGH BATTERIES HOT WIRE. <br />ESS DETAILS <br />MODEL NAME <br />PEAK OUTPUT POWER <br />TOTAL CAPACITY <br />ENPHASE IQ BATTERY-5P-1P-NA <br />6.14 kVA <br />5.0 kWh <br />NOTE : ENERGY STORAGE SYSTEMS (ESS) SHALL NOT BE <br />LOCATED LESS THAN 3 FEET FROM DOORS AND WINDOWS <br />DIRECTLY ENTERING THE DWELLING UNIT PER 2022 <br />CALIFORNIA RESIDENTIAL CODE R328.4. <br />NOTE : ALL EQUIPMENT LISTED IS SUBJECT TO <br />AVAILABILITY AND MAY BE REPLACED WITH AN <br />EQUIVALENT PRODUCT. <br />2329 N Fairmont Ave - <br />201821764/3/2024