My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2130 S Kilson Dr - Plan
PBA
>
Building
>
ProjectDox
>
K
>
Kilson Dr
>
2130 S Kilson Dr
>
2130 S Kilson Dr - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/1/2025 12:02:06 PM
Creation date
6/1/2025 12:01:55 PM
Metadata
Fields
Template:
Plan
Permit Number
20179828
101115367
Full Address
2130 S Kilson Dr
Document Relationships
101115367 - Permit
(Permit - Plan)
Path:
\Building\Permits\K\Kilson Dr\2130 S Kilson Dr
20179828 - Permit
(Permit - Plan)
Path:
\Building\Permits\K\Kilson Dr\2130 S Kilson Dr
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
19
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
CAUTION <br />POWER TO THIS BUILDING IS ALSO SUPPLIED FROM THE FOLLOWING <br />SOURCES WITH DISCONNECTS LOCATED AS SHOWN: <br />SYSTEM <br /> LABELING DETAIL <br />(STICKER TO BE LOCATED ON <br />CONDUIT WITH DC CURRENT <br />EVERY 4' HORIZONTALLY OR <br />10' VERTICALLY AND 1' FROM <br />EACH SIDE OF A BEND) <br />(TO BE LOCATED ON <br />SUB-PANEL ONLY <br />WHEN SUB-PANEL IS <br />DEDICATED FOR PV ONLY) <br />(STICKER LOCATED <br />INSIDE PANEL <br />NEXT TO SOLAR BREAKER) <br />(STICKER LOCATED <br />INSIDE PANEL <br />BELOW PV BREAKER) <br />PV ARRAY J BOX <br />INVERTER <br />INTEGRATED <br />DC DISCONNECT <br />PV SUB-PANEL <br />*if applicable <br />SUB-PANEL <br />*if applicable AC <br />DISCONNECT <br />*if applicable <br />METER <br />MAIN SERVICE <br />PANEL <br />*if applicable <br />(STICKER LOCATED <br />ON THE PV SUB PANEL) <br />CAUTION <br />AUTHORIZED SOLAR <br />PERSONNAL ONLY! <br />CAUTION <br />SOLAR DC CURRENT PRESENT <br />DURING DAYLIGHT HOURS <br />WARNING! <br />ELECTRIC SHOCK HAZARD. <br />IF GROUND FAULT IS INDICATED, <br />NORMALLY GROUNDED <br />CONDUCTORS MAY BE <br /> UNGROUNDED AND ENERGIZED. <br />DC DISCONNECT <br />DC PHOTOVOLTAIC POWER SOURCE <br />RATED MAX POWER POINT CURRENT- AMPS <br />RATED MAX POWER POINT VOLTAGE- VOLTS <br />MAXIMUM SYSTEM VOLTAGE- VOLTS <br />SHORT CIRCUIT CURRENT- AMPS <br />WARNING! <br />ELECTRIC SHOCK HAZARD. <br />DO NOT TOUCH THE TERMINALS. <br />TERMINALS ON BOTH THE LINE AND <br />LOAD SIDES MAY BE ENERGIZED IN <br />THE OPEN POSITION. <br />PV LOAD CENTER SIZED FOR PV <br />BREAKERS ONLY OR RENDERED UNABLE <br />TO ACCEPT ANY ADDITIONAL LOADS. <br />PV SUB-PANEL ONLY <br />AC DISCONNECT <br />AC PHOTOVOLTAIC POWER SOURCE <br />RATED AC OUTPUT CURRENT: A MAX <br />NOMINAL AC OPERATING VOLTAGE: 240 Vac <br />THIS PANEL FED BY <br />MULTIPLE SOURCES <br />(UTILITY & SOLAR) <br />SOLAR WARNING! <br />INVERTER OUTPUT CONNECTION. DO NOT <br />RELOCATE THIS OVERCURRENT DEVICE <br />Permanent directory or plaque providing location of service disconnecting means and photovoltaic system <br />disconnecting means, if not located at the same location. (Plaques shall be metal or plastic, with engraved or <br />machine printed letters, or electro-photo plating, in a contrasting color to the plaque. Plaques shall be permanently <br />attached to the equipmenq or in the required location using an approved method that is suitable to withstand the <br />environment to which it is exposed. Plaques and signage shall meet legibility, defacemet, exposure and adhesion <br />requirements of Underwriters Laboratories marking and labeling system 969(UL969). <br />40.838 <br />LABEL 1 LABEL 2 LABEL 3 LABEL 4 LABEL 5 <br />LABEL 6 LABEL 7 LABEL 8 LABEL 9 LABEL 10 <br />LABEL 11 LABEL 12 <br />87 <br />109 <br />12 <br />7 <br />7 <br />9 <br />8 <br />10 <br />7 <br />7 <br />9 <br />8 <br />1011 <br />7 <br />4 51 <br />2 <br />DIRECTORY <br />MARKINGS, LABELS AND WIRING SIGNS <br />A. Purpose: Provide emergency responders with appropriate warning and guidance with respect to isolating solar electric system. <br />This can facilitate identifying energized electrical lines that connect solar panels to the inverter, as these should not be cut when venting for smoke removal <br />B. Main Service Disconnect. <br />1. Residential buildings - The marking main be placed within the main service disconnect. The marking shall be placed <br />outside cover if the main service disconnect is operable with the service panel closed. <br />2. Commercial buildings - Tha marking shall be placed adjacent to the main service disconnect clearly visible from the location where the level is operated <br />3. Markings: Verbiage, Format and Type of Material. <br />a. Verbiage: CAUTION: SOLAR ELECTRIC SYSTEM CONNECTED <br />b. Format: White lettering on a red background. Minimum 3/8 inches letter height. All letters shall be capitalized. Arial or similar font, non bold. <br />c. Material: Reflective, weather resistant material suitable for the environment (use UL - 969 as standard for weather rating). Durable adhesive materials meet this <br />requirement. <br />C.Marking Requirements on DC conduit, raceways, enclosures, cable assemblies, DC combiners and junction boxes: <br />1. Markings: Verbiage, Format and Type of Material. <br />a. Placement : Markings shall be placed every 10 feet on all interior and exterior DC conduits, raceways, enclosures, and cable assemblies, <br />at turns, above and for below penetrations, all DC combiners and junction boxes <br />b. Verbiage: CAUTION: SOLAR CIRCUIT Note: The format and type of material shall adhere to "V. V-3b, c" of this requirement. <br />c. Inverters are not required to have caution markings <br />1.Marking is required on all interior and exterior DC conduit raceways,enclosures,cable assemblies,and junction boxes,combiner boxes and disconnects. <br />2.The materials used for marking shall be reflective,weather resistant material suitable for the environment. <br />Minimum 3/8 "letter height; all upper case letters Arial or similar font; Red background with white lettering. <br />3.Marcking shall contain the words: WARNING : PHOTOVOLTAIC POWER SOURCE. <br />4.Marking shall be placed adjacent to the main service disconnect in a location clearly visible from the location where the disconnect is operated PV 3.0 <br />PV SYSTEM AS INDICATED <br />Scale:Project: <br />Project Name: <br />Property Adress: <br />Arnuelo Osorio <br />2130 S Kilson Dr, <br />Santa Ana, CA 92707 <br />Drawn by:New@engineerinc.io <br />05/26/2023DATE: <br />SOLAR PV SYSTEM EQUIPPED <br />WITH RAPID SHUTDOWN <br />TURN RAPID SHUTDOWN <br />SWITCH TO THE <br />"OFF" POSITION TO <br />SHUT DOWN PV SYSTEM <br />AND REDUCE <br />SHOCK HAZARD <br />IN THE ARRAY <br />SOLAR ELECTRIC <br />PV PANELS <br /> 180 ° <br /> 90 ° 270 ° <br />0° <br />S <br />W <br />N <br />E <br />CONTRACTOR <br />Green Day Power <br />Address: 9745 Business Park Dr <br />Sacramento, CA 95827 <br />Phone number: 916-758-8030 <br />E-mail: hello@greendaypower.com <br />SERVICE POINT & <br />UTILITY METERING <br />ENPHASE COMBINER BOX <br />You Are <br />Here <br />PV SOLAR ARRAY <br />Exp. Date : 3/31/2024 <br />Date Certified and <br />Signed: 06/02/2023 <br />2130 S Kilson Dr. <br />06/07/23
The URL can be used to link to this page
Your browser does not support the video tag.