My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2130 S Kilson Dr - Plan
PBA
>
Building
>
ProjectDox
>
K
>
Kilson Dr
>
2130 S Kilson Dr
>
2130 S Kilson Dr - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/1/2025 12:02:06 PM
Creation date
6/1/2025 12:01:55 PM
Metadata
Fields
Template:
Plan
Permit Number
20179828
101115367
Full Address
2130 S Kilson Dr
Document Relationships
101115367 - Permit
(Permit - Plan)
Path:
\Building\Permits\K\Kilson Dr\2130 S Kilson Dr
20179828 - Permit
(Permit - Plan)
Path:
\Building\Permits\K\Kilson Dr\2130 S Kilson Dr
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
19
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
ATTACHMENT <br />LAYOUT <br />DESIGN CRITERIA <br />Modules: <br />Max Distributed Load: 3 PSF <br />POINT LOAD CALCULATION PER ARRAY <br />Module Weight (lbs) <br /># Of Modules <br />49.6 <br />Total Module Weight (lbs) <br />Rack Weight (lbs) <br />Microinverters Weight (lbs) <br />Total System Weight (lbs) <br /># Of Standoffs <br />Max Span Between Standoffs (in) <br />Loading Per Standoff (lbs) <br />Total Area (sq.ft.) <br />Loading (PSF) <br />1339.2 <br />267.84 <br />64.26 <br />1671.3 <br />48 <br />72 <br />34.82 <br />594 <br />2.81 <br />RAIL <br /> ATTACHMENT <br />Truss 2 x 4 @ 24" O.C. <br />27 <br />27 <br />PV 5.0 <br />PV SYSTEM AS INDICATED <br />Scale: Project: <br />Project Name: <br />Property Adress: <br />Arnuelo Osorio <br />2130 S Kilson Dr, <br />Santa Ana, CA 92707 <br />Drawn by:New@engineerinc.io <br />05/26/2023DATE: <br />Prior to the commencement of work, the contractor shall verify <br />the existing roof and framing conditions. Notify <br />New@engineerinc.io of any Discrepancies prior to starting <br />construction. <br />Prior to the commencement of work, the contractor shall inspect <br />framing for any damage such as water damage, cracked framing, <br />etc. and notify New@engineerinc.io if any issues are found. <br />These Plans are stamped for structural code compliance of the <br />roof framing supporting the proposed PV installation reference <br />only. These plans are not stamped for water leakage. PV <br />modules, racking, and attachment components must follow <br />manufacturer guidelines and requirements. <br />Attachments to be installed in a staggered orientation to properly <br />distribute loads. <br />Blocking <br />DF#2 <br />2 x 6 <br />1 Layer of . <br />Plywood & Building Felt <br />Solar Module <br />6" <br />Attachment <br />ROOF SECTION DETAIL <br />Truss 2 x 4 @ 24" O.C. <br />COMP. SHINGLE <br />CONTRACTOR <br />Green Day Power <br />Address: 9745 Business Park Dr <br />Sacramento, CA 95827 <br />Phone number: 916-758-8030 <br />E-mail: hello@greendaypower.com <br />UNIRAC FLASHLOC DUO ATTACHMENT DETAILS <br />PART TABLE <br />P N DESCRIPTION <br />004275M FLASHLOC DUO MILL, 20 PACK <br />004275D FLASHLOC DUO DARK, 20 PACK <br />BND T-BOLT & <br />NUT 3 8´x1´ SS <br />SS SERRATED <br />FLANGE NUT <br />FLASHLOC DTD <br />MILL OR DARK <br />12-14 SCREW, HWH, SS, SELF-DR <br />W 12 EPDM WASHER <br />512" <br />312" <br />258" <br />438" <br />Wind Speed: 110 mph <br />16'-3" <br />12'-9" <br />Date Certified and <br />Exp. Date : 3/31/2024 <br />Signed: 06/02/2023 <br />Professional Certification. I hereby certify that these documents <br />were prepared or approved by me, and that I am a duly licensed <br />professional engineer under the laws of the State of California. <br />License No. ____________, Expiration Date: _______________ 88083 03/31/2024 <br />Engineerinc.io, <br />303 N Glenoaks Blvd <br />Burbank, CA 91502 <br />(747) 333-5991 <br />2130 S Kilson Dr. <br />06/07/23
The URL can be used to link to this page
Your browser does not support the video tag.