PV-6REV: A 10/5/2022 <br />UBALDO RAMIREZ LOZA <br />2229 CYPRESS AVE, <br />SANTA ANA, CALIFORNIA 92707 <br />APN # 40314209 TEL #: (714) 206-1647 <br />CLIENT: <br />CALCS <br />CSLB # 619149 CLASS: B, C-10 <br />NAME: GARY GIETZ, JACK MCCLARY <br />SIGNED: 10/5/2022 PHONE 310.904.6139 <br />ENERGY SERVICE PARTNERS <br />970 W 190TH ST, STE 302 <br />TORRANCE, CA 90502 <br />CONTRACTOR: <br />ELECTRICAL CALCULATIONS AC WIRE SIZING CALCULATIONS <br />AT ARRAY Enphase QCable = 12 AWG, 30 A @90⁰C <br />BRANCH CIRCUITS (Max Micro Inverter Output) x (Continuous Load)[210.19(A)(1)] <br />x (# Micros In Branch Circuit)=1.45 A X1.25 X 7 12.69 A <br />TOTAL AMPACITY (High Temp)[Table 310(B)(2)(A) x (Conductor Ampacity)[Table <br />310.15(B)(16)] x (Conduit Fill)[Table 310.15(B)(3)(a)]0.91 X 30 A X 1 27.30 A <br />12.69 A < 27.30 A Therefore 12 AWG/ Q CABLE is sufficient <br />AFTER JBOX Wire = 10 AWG, 40 A @ 90⁰C <br />BRANCH CIRCUITS (Max Micro Inverter Output) x (Continuous Load)[210.19(A)(1)] <br />x (# Micros In Branch Circuit)=1.45 A X 1.25 X 7 12.69 A <br />TOTAL AMPACITY (High Temp)[Table 310(B)(2)(A) x (Conductor Ampacity)[Table <br />310.15(B)(16)] x (Conduit Fill)[Table 310.15(B)(3)(a)]0.91 X 40 A X 1 36.40 A <br />12.69 A < 36.40 A Therefore 10 AWG is sufficient <br />AC WIRE SIZING CALCULATIONS <br />AFTER COMBINER BOX Wire = 10 AWG, 40 A @ 90⁰C <br />MAX AC OUTPUT CURRENT (Σ of Micros in Branch Circuits ) x (Max Micro Inverter Output Current) <br /> x (Continuous Load)[210.19(A)(1)]7 X 1.45 A X 1.25 12.69 A <br />TOTAL AMPACITY (High Temp)[Table 310(B)(2)(A) x (Conductor Ampacity)[Table <br />310.15(B)(16)] x (Conduit Fill)[Table 310.15(B)(3)(a)]0.91 X 40 A X 1 36.40 A <br />12.69 A < 36.40 A Therefore 10 AWG is sufficient <br />OCPD CALCULATIONS <br />MAX AC OUTPUT CURRENT (Σ of Micros in Branch Circuits ) x (Max Micro Inverter Output Current) <br /> x (Continuous Load)[210.19(A)(1)]7 X 1.45 A X 1.25 12.69 A <br />12.69 A ---> 20 A Overcurrent Protection <br />AFTER LOAD CENTER Wire = 6 AWG, 75 A @ 90⁰C <br />MAX AC OUTPUT CURRENT <br />[Existing system #1 Output]+[Existing system #2 Output] + (Σ of Micros in <br />Branch Circuits ) x (Max Micro Inverter Output Current) x (Continuous <br />Load)[210.19(A)(1)] <br />[((E)14.5A + (E)21A <br />+ (7x1.45A))x1.21]57.06 <br />TOTAL AMPACITY (High Temp)[Table 310(B)(2)(A) x (Conductor Ampacity)[Table <br />310.15(B)(16)] x (Conduit Fill)[Table 310.15(B)(3)(a)]0.91 X 75 A X 1 68.25 <br />57.06 A < 68.25 A Therefore 6 AWG is sufficient <br />OCPD CALCULATIONS <br />MAX AC OUTPUT CURRENT <br />[Existing system #1 Output]+[Existing system #2 Output] + (Σ of Micros in <br />Branch Circuits ) x (Max Micro Inverter Output Current) x (Continuous <br />Load)[210.19(A)(1)] <br />[((E)14.5A + (E)21A <br />+ (7x1.45A))x1.21]57.06 <br />57.06 A ---> 60 A Overcurrent Protection <br />INVERTER CHARACTERISTICS - ENPHASE IQ7A-72-2US <br />MAX OUTPUT POWER 349 W <br />SYSTEM OPERATING VOLTAGE 33/58 V <br />MAX CONTINOUS OUTPUT CURRENT 1.45 A <br />MAX INPUT VOLTAGE 58 V <br />SYSTEM SHORT CIRCUIT CURRENT 13.26 A <br />CEC MAX EFFICIENCY 97 % <br />TEMPERATURE ADDERS <br />CONDUIT TO BE INSTALLED <br />MIN. OF 7 8" ABOVE ROOF <br />HIGH TEMPERATURE 39 °C <br />LOW TEMPERATURE -7 °C <br />TEMP ADDER FOR ROOF RUN 0 °C <br />TEMP ADDER FOR ATTIC RUN 7 °C <br />SYSTEM CHARACTERISTICS VALUES <br />MAX POWER-POINT CURRENT (Module IMP) x (# Strings)9.05 A X 1 9.05 A <br />MAX POWER-POINT VOLTAGE (Module VMP) x <br />(# Modules / Largest String)43.1 V X 1 43.1 V <br />MAX SYSTEM VOLTAGE (Voltage Correction Factor) x (Module <br />VOC) x (# Modules / Largest String)51.9 V X 1 X 1.14 59.17 V <br />MAX CIRCUIT CURRENT (Module ISC) x (# Strings) x <br />(Continuous Load)9.82 A X 1 X 1.25 12.28 A <br />DC DISCONNECT VALUES <br />RATED MAX POWER-POINT CURRENT (IMP) 10.68 A <br />RATED MAX POWER-POINT VOLTAGE (VMP) 37.00 V <br />MAX SYSTEM VOLTAGE (VOC)44.30 V <br />MAX SHORT CIRCUIT CURRENT (ISC)11.44 A <br />MODULE CHARACTERISTICS - CSI SOLAR CS3N-395MS [BLK] <br />MAX POWER (PMAX) @ STC 395 W <br />OPEN CIRCUIT VOLTAGE (VOC)44.3 V <br />SHORT CIRCUIT CURRENT (ISC)11.44 A <br />MAX POWER VOLTAGE (VMP)37.2 V <br />MAX POWER CURRENT (IMP)10.68 A <br />SERIES FUSE RATING 20 A <br />2229 Cypress Ave <br />- <br />101112580-201778 <br />10 <br />11/04/22