Laserfiche WebLink
PowerOptimizer <br />ForNorthAmerica <br />P320/P340/P370/P400/P401/P405/P485/P505 <br />25 <br />YEAR <br />WARRANTY <br />PVpoweroptimizationat the module-level <br />Specifically designed to workwith SolarEdge <br />inverters <br />Up to 25%more energy <br />Superior efficiency (99.5%) <br />Mitigates all types of module mismatch losses, <br />from manufacturing tolerance to partial <br />shading <br />Flexible system design for maximum space <br />utilization <br />Fast installation with a single bolt <br />Next generation maintenance with module- <br />level monitoring <br />Meets NECrequirements for arc fault <br />protection (AFCI) and Photovoltaic Rapid <br />Shutdown System (PVRSS) <br />Module-level voltage shutdown for installer <br />and firefighter safety <br />solaredge.com <br />PO <br />W <br />E <br />R <br />O <br />P <br />T <br />I <br />M <br />I <br />Z <br />E <br />R <br />PowerOptimizer <br />ForNorthAmerica <br />P320 / P340 / P370 / P400 / P401 / P405 / P485 / P505 <br />Optimizer model <br />(typical module <br />compatibility) <br />P320 <br />(for 60-cell <br />modules) <br />P340 <br />(for high- <br />power <br />60-cell <br />modules) <br />P370 <br />(for higher- <br />power <br />60 and 72- <br />cell <br />modules) <br />P400 <br />(for 72 & <br />96-cell <br />modules) <br />P401 <br />(for high <br />power60 <br />and 72 cell <br />modules) <br />P405 <br />(for high- <br />voltage <br />modules) <br />P485 <br />(for high- <br />voltage <br />modules) <br />P505 <br />(for higher <br />current <br />modules) <br />INPUT <br />Rated Input DCPower(1)320 350 370 400 485 505 W <br />Absolute MaximumInput Voltage <br />(Voc at lowest temperature)48 60 80 60 125(2)83(2)Vdc <br />MPPT Operating Range 8 - 48 8 -60 8 -80 8-60 12.5 -105 12.5 -83 Vdc <br />Maximum Short Circuit Current <br />(Isc)11 11.02 11 10.1 11.75 11 14 Adc <br />Maximum DCInput Current 13.75 12.5 14.65 12.5 17.5 Adc <br />MaximumEfficiency 99.5 % <br />Weighted Efficiency 98.8 98.6 % <br />Overvoltage Category II <br />OUTPUT DURING OPERATION (POWER OPTIMIZER CONNECTED TO OPERATING SOLAREDGE INVERTER) <br />Maximum Output Current 15 Adc <br />MaximumOutput Voltage 60 85 Vdc <br />OUTPUT DURING STANDBY (POWEROPTIMIZERDISCONNECTED FROM SOLAREDGE INVERTERORSOLAREDGE INVERTEROFF) <br />Safety Output Voltage per Power <br />Optimizer 1 ± 0.1 Vdc <br />STANDARD COMPLIANCE <br />EMC FCCPart15 Class B, IEC61000-6-2, IEC61000-6-3 <br />Safety IEC62109-1 (class II safety), UL1741 <br />Material UL94 V-0, UV Resistant <br />RoHS Yes <br />INSTALLATION SPECIFICATIONS <br />Maximum Allowed System <br />Voltage 1000 Vdc <br />Compatible inverters All SolarEdge Single Phase and Three Phase inverters <br />Dimensions (W x L x H)129 x 153 x 27.5 / 5.1 x 6 x 1.1 129 x 153 x 33.5 <br />/ 5.1 x 6 x 1.3 <br />129 x 153 x 29.5 <br />/5.1 x 6 x 1.16 129 x 159 x 49.5 / 5.1 x 6.3 x 1.9 129 x 162 x 59 <br />/5.1 x 6.4 x 2.3 <br />mm <br />/ in <br />Weight (including cables)630 /1.4 750 /1.7 655 /1.5 845 /1.9 1064 /2.3 gr /lb <br />Input Connector MC4(3)Single or dual <br />MC4(3)(4)MC4(3) <br />Input Wire Length 0.16 / 0.52 0.16 or 0.9 <br />/0.52 or 2.95(5)0.16 / 0.52 m / ft <br />Output Wire Type /Connector Double Insulated / MC4 <br />Output Wire Length 0.9 /2.95 1.2 /3.9 m / ft <br />Operating Temperature Range(6)-40 to +85 / -40 to +185 Ü&/Ü) <br />Protection Rating IP68 /7\SH 3 <br />Relative Humidity 0- 100 % <br />  Rated power of the module at STCwill not exceed the optimizer “Rated Input DC Power”. Modules with up to +5% power tolerance are allowed <br />  NEC 2017 requires max input voltage be not more than 80V <br />  For other connector types please contact SolarEdge <br />  For dual version for parallel connection of two modules use P485-4NMDMRM. In the case of an odd number of PV modules in one string, installing one P485 dual version power optimizer connected to <br /> one PV module. When connecting a single module seal the unused input connectors with the supplied pair of seals <br />  Longer inputs wire length are available for use. For 0.9minput wire length order P401-xxxLxxx <br />  For ambient temperature above +85°C/ +185°F power de-rating is applied. Refer to Power Optimizers Temperature De-Rating Technical Note for more details <br />PVSystem DesignUsing a <br />SolarEdge Inverter(7)(8) <br />Single Phase <br />HD-Wave Single phase Three Phase for <br />208Vgrid <br />Three Phase for <br />277/480Vgrid <br />Minimum String Length <br />(Power Optimizers) <br />P320, P340, P370, <br />P400, P401 8 10 18 <br />P405, P485, P505 6 8 14 <br />Maximum String Length (Power Optimizers)25 25 50(9) <br />Maximum Power per String <br />5700 (6000 with <br />SE7600-US - SE11400- <br />US) <br />5250 6000(10)12750(11) W <br />Parallel Strings of 'L੔HUHQW Lengths or Orientations Yes <br />    )RU GHWDLOHG VWULQJ VL]LQJ LQIRUPDWLRQ UHIHU WR KWWSZZZVRODUHGJHFRPVLWHVGHIDXOWILOHVVWULQJBVL]LQJBQDSGI <br />    ,W LV QRW DOORZHG WR PL[ 333 ZLWK 33333 LQ RQH VWULQJ <br />    $ VWULQJ ZLWK PRUH WKDQ  RSWLPL]HUV GRHV QRW PHHW 1(& UDSLG VKXWGRZQ UHTXLUHPHQWV VDIHW\ YROWDJH ZLOO EH DERYH WKH 9 UHTXLUHPHQW <br />   )RU 9 JULG LW LV DOORZHG WR LQVWDOO XS WR : SHU VWULQJ ZKHQ WKH PD[LPXP SRZHU GL੔HUHQFH EHWZHHQ HDFK VWULQJ LV : <br />   )RU 9 JULG LW LV DOORZHG WR LQVWDOO XS WR : SHU VWULQJ ZKHQ WKH PD[LPXP SRZHU GL੔HUHQFH EHWZHHQ HDFK VWULQJ LV : <br />© SolarEdge Technologies Ltd. All rights reserved. SOLAREDGE, the SolarEdge logo, OPTIMIZED BY SOLAREDGE are trademarks or registered trademarks of SolarEdge Technologies, Inc. <br />All other trademarks mentioned herein are trademarks of their respective owners. Date:/2021 DS-000044-1.-NA. Subject to change without notice. <br />40 <br />2110 W 7th St - <br />2017778512/28/22