Laserfiche WebLink
POWER TO THIS BUILDING ALSO SUPPLIED <br />FROM THE FOLLOWING SOURCES WITH <br />DISCONNECTS LOCATED AS SHOWN <br />CAUTION <br />SERVICE BY QUALIFIED PERSONNEL ONLY <br />N <br />TO BE INSTALLED ON THE OUTSIDE COVER <br />OF THE MAIN SERVICE DISCONNECT: <br />ALL SIGNAGE SHALL BE REFLECTIVE, UV RESISTANT <br />PLASTIC, RED IN COLOR WITYH WHITE LETTERING, <br />AND ATTACHED WITH WEATHERPROOF ADHESIVE <br />OR OTHER APPROVED METHOD. ALL LETTERS SHALL <br />BE A MINIMUM OF 3 <br />8" HEIGHT AND ALL CAPITALIZED. <br />SYSTEM SIGNAGE <br />ALL CONDUIT, JUNCTION BOXES AND OTHER <br />ENCLOSURES SHALL BE MARKED AT 10' MAX <br />INTERVALS AND AT ALL BENDS, TERMINATIONS, <br />SPLICES OR CONNECTIONS WITH "WARNING: <br />PHOTOVOLTAIC POWER SOURCE'. <br />TO BE INSTALLED AT ALL SERVICEABLE PANELS <br />OR BOXES AND AT ALL DISCONNECTS: <br />WARNING! <br />ELECTRIC SHOCK HAZARD <br />TERMINALS ON BOTH LINE AND LOAD <br />SIDES MAY BE ENERGIZED IN THE <br />OPEN POSITION <br />TO BE INSTALLED ON THE <br />FRONT OF THE AC DISCONNECT: <br />RAPID SHUTDOWN SWITCH FOR SOLAR SYSTEM <br />RATED AC OUTPUT CURRENT = 35.2 A <br />NOMINAL OPERATING AC VOLTAGE = 240 V <br />TO BE INSTALLED AT THE BACKFEED <br />BREAKER SERVING THE PV SOLAR SYSTEM: <br />WARNING! <br />POWER SOURCE OUTPUT CONNECTION <br />DO NOT RELOCATE THIS OVERCURRENT DEVICE <br />TURN RAPID SHUTDOWN <br />SWITCH TO THE <br />"OFF" POSITION TO <br />SHUT DOWN PV SYSTEM <br />AND REDUCE <br />SHOCK HAZARD <br />IN THE ARRAY <br />SOLAR PV SYSTEM EQUIPPED <br />WITH RAPID SHUTDOWN <br />SOLAR ELECTRIC <br />PV PANELS <br />TO BE INSTALLED ON THE FRONT OF THE MAIN <br />SERVICE DISCONNECT: <br />"SOLAR PV SYSTEM EQUIPPED WITH RAPID <br />SHUTDOWN" SHALL BE BLACK LETTERING ON <br />YELLOW BACKGROUND. THE REMAINDER OF THE <br />SIGN SHALL BE BLACK LETTERING ON THE WHITE <br />BACKGROUND. <br />SYSTEM CALCULATIONS: <br />NUMBER OF MODULES IN CIRCUIT#1 = 9 <br />MODULE MAX OUTPUT CURRENT = 1.6A <br />(9)(1.6A)(1.25) = 18A[Ic], USE 20A BREAKER <br />NUMBER OF MODULES IN CIRCUIT#2 = 7 <br />(7)(1.6A)(1.25) = 14A, USE 20A BREAKER <br />NUMBER OF MODULES IN CIRCUIT#3 = 6 <br />(6)(1.6A)(1.25) = 12A, USE 20A BREAKER <br />TOTAL NUMBER OF MODULES = 22 <br />(22)(1.6A)(1.25) = 44A[I], USE 50A FUSE <br />WIRE CALCULATIONS: <br />NOTE: DISTANCE ABOVE ROOF TO BOTTOM OF CONDUIT: >23mm (7 <br />8") <br />FROM THE MODULES TO THE LOAD CENTER: <br />AMBIENT TEMPERATURE = 34°C <br />ADJUSTMENT FACTOR PER TABLE 310.15(B)(2)(b) FOR 90°C INSULATED CONDUCTOR AT <br />34°C = 1.05 <br />Ic = 18A <br />18A/1.05 = 17.14A <br />NUMBER OF CURRENT CARRYING CONDUCTORS IN CONDUIT = 6 <br />ADJUSTMENT FACTOR PER TABLE 310.15(B)(3)(a) FOR CONDUIT FILL (4-6 CONDUCTORS IN <br />CONDUIT)=0.80 <br />17.14A/0.80 = 21.425A <br />SELECT WIRE SIZE WITH AMPACITY GREATER THAN 21.425A, USE 10 AWG THWN-2 COPPER <br />WIRE WITH AN AMPACITY OF 40A. <br />SELECT CONDUIT FOR (6)10 AWG THWN-2 & (1)10 AWG GROUND = 3 <br />4" EMT CONDUIT. <br />FROM THE LOAD CENTER TO THE FUSED AC DISCONNECT: <br />ADJUSTMENT FACTOR PER TABLE 310.15(B)(2)(a) FOR 90°C INSULATED CONDUCTOR AT <br />34°C = 0.96 <br />I = 44A <br />44A/0.96 = 45.83A <br />SELECT WIRE SIZE WITH AMPACITY GREATER THAN 45.83A, USE 8 AWG THWN-2 COPPER <br />WIRE WITH AN AMPACITY OF 55A. <br />SELECT CONDUIT FOR (3)8 AWG THWN-2 & (1)10 AWG GROUND = 3 <br />4" EMT CONDUIT. <br />ECOSOLAR USA <br />ELECTRICAL LLC <br />13962 SEABOARD CIRCLE <br />GARDEN GROVE, CA 92840 <br />PH: 714.265.9077 <br />SCOPE OF WORK: <br />INSTALL (22) SUNPOWER SPR-M410-BLK-H-AC SOLAR ELECTRIC MODULES ON THE <br />EXISTING 1ST STORY W-TILE ROOF. INSTALL ASSOCIATED MOUNTING HARDWARE, <br />JUNCTION BOXES, CONDUIT, CONDUCTORS AND GROUNDING. INSTALL (1) FUSED AC <br />DISCONNECT, (1) LOAD CENTER, AND CONNECT TO SCE INSTALLED GMA. <br />DAVID Q HOANG C10 - 1045300 <br />DATE: 11/17/22 <br />PLANS PREPARED BY: <br />R. ABANTO JR. <br />HOMEOWNER: JESSE TA <br />PH: (714) 391-1180 <br />ADDRESS: 2301 HUCKLEBERRY ROAD <br />SANTA ANA, CA, 92706 <br />REV DESCRIPTION <br />AHJ REDLINEA <br />DATE <br />11.17.22 <br />SOLAR ARRAY <br />(ON ROOF) <br />AC LOAD CENTER <br />AC DISCONNECT <br />SERVICE POINT & <br />UTILITY METERING <br />PV3 <br />A <br />This item has been digitally signed <br />and sealed on Nov 21, 2022 <br />2301 W <br />Huckleberry Rd12/15/22