My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2137 N Spruce St - Plan
PBA
>
Building
>
ProjectDox
>
S
>
Spruce St
>
2137 N Spruce St
>
2137 N Spruce St - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/1/2025 12:02:30 PM
Creation date
6/1/2025 12:02:08 PM
Metadata
Fields
Template:
Plan
Permit Number
20179764
101115269
Full Address
2137 N Spruce St
Document Relationships
101115269 - Permit
(Permit - Plan)
Path:
\Building\Permits\S\Spruce St\2137 N Spruce St
20179764 - Permit
(Permit - Plan)
Path:
\Building\Permits\S\Spruce St\2137 N Spruce St
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
44
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
100'-0" <br />60 <br />' <br />- <br />0 <br />" <br />100'-0" <br />60 <br />' <br />- <br />0 <br />" <br />23'-2" <br />9' <br />- <br />1 <br />" <br /> <br />3' <br />- <br />1 <br />1 <br />" <br />18'-6" <br />20 <br />' <br />- <br />1 <br />1 <br />" <br />25'-3" <br />13'-7" <br />1 <br />4 <br />' <br />- <br />7 <br />" <br />SATELLITE VIEW <br />SCALE: NTS <br />SCALE: NTS <br />COVER SHEET <br />SHEET NAME <br />SHEET SIZE <br />SHEET NUMBER <br />ANSI B <br />11" X 17" <br />SIGNATURE WITH SEAL <br />PROJECT NAME & <br />ADDRESS <br />CS <br />DATE: 4/28/2023 <br />21 <br />3 <br />7 <br /> <br /> N <br /> <br />S <br />P <br />R <br />U <br />C <br />E <br /> <br />S <br />T <br />SA <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br /> <br />, <br /> <br />C <br />A <br />, <br /> <br />9 <br />2 <br />7 <br />0 <br />6 <br />YA <br />L <br />I <br />N <br />D <br />A <br /> <br />M <br />E <br />Z <br />A <br /> R <br />E <br />S <br />I <br />D <br />E <br />N <br />C <br />E <br />DESCRIPTION DATE REV <br />REVISIONS <br />INITIAL DESIGN 4/11/2023 00 <br />LEVION CONSTRUCTION LLC <br />49 CALYPSO IRVINE <br />CA 92618 <br />CONTRACTOR LIC#: #1096696 <br />PHONE #: 951-554-2201 <br />GENERAL B <br />ZACHARY WINGER <br />PHOTOVOLTAIC ROOF MOUNT SYSTEM <br />15 MODULES-ROOF MOUNTED - 6.000 KW DC, 5.440 KW AC, 2137 N SPRUCE ST , SANTA ANA , CA 92706 <br />GOVERNING CODES <br />ALL WORK SHALL CONFORM TO THE FOLLOWING CODES <br />1. 2022 CA BUILDING CODE <br />2. 2022 CA ELECTRICAL CODE <br />3. 2022 CA FIRE CODE <br />4. 2022 CA RESIDENTIAL CODE <br />5. ANY OTHER LOCAL AMENDMENTS <br />2 <br />CS <br />3 <br />CS <br />N <br />GENERAL NOTES: <br />a. INSTALLATION OF SOLAR <br />PHOTOVOLTAIC SYSTEM SHALL BE IN <br />ACCORDANCE WITH CEC AND ALL <br />OTHER APPLICABLE CEC CODES <br />WHERE NOTED OR EXISTING. <br />b. PROPER ACCESS AND WORKING <br />CLEARANCE AROUND EXISTING AND <br />PROPOSED ELECTRICAL EQUIPMENT <br />WILL COMPLY WITH CEC. <br />c. ALL CONDUCTORS, INCLUDING THE <br />GROUNDING ELECTRODE CONDUCTOR <br />SHALL BE PROTECTED FROM PHYSICAL <br />DAMAGE IN ACCORDANCE WITH CEC <br />d. THE PV MODULES ARE CONSIDERED <br />NON-COMBUSTIBLE; THIS SYSTEM IS <br />UTILITY INTERACTIVE PER UL 1741 AND <br />DOES NOT INCLUDE STORAGE <br />BATTERIES OR OTHER ALTERNATIVE <br />STORAGE SOURCES. <br />e. ALL DC WIRES SHALL BE SIZED <br />ACCORDING TO CEC <br />f. DC CONDUCTORS SHALL BE WITHIN <br />PROTECTED RACEWAYS <br />g. ALL SIGNAGE TO BE PLACED IN <br />ACCORDANCE WITH LOCAL <br />JURISDICTIONAL BUILDING CODE. <br />h. PV MODULES TO BE RATED UL 1703 <br />CLASS C FIRE RATING OR BETTER. <br />i. ALL EQUIPMENT TO BE CERTIFIED BY A <br />NATIONAY RECOGNIZED TESTING <br />LABORATORY. <br />j. A 36" WIDE PATHWAY SHALL BE <br />PROVIDED TO THE EMERGENCY <br />ESCAPE AND RESCUE OPENING. <br />k. PV ARRAYS SHALL BE LOCATED AT <br />LEAST 2H2 (2 TIMES THE MAXIMUM <br />HEIGHT OF THE MODULES ABOVE <br />ROOF DECK) FROM THE ROOF EDGE, A <br />GABLE RIDGE OR A HIP RIDGE. (ASCE <br />7-16 – 29.4.4) <br />l. MODULES ARE TO BE AT 2” MINIMUM <br />AND 10” MAXIMUM FROM THE ROOF <br />DECK. (ASCE 7-16 – 29.4.4) <br />SYSTEM SIZE: 6.000 kW DC <br /> 5.440 kW AC <br />MODULE TYPE & AMOUNT: (15) CANADIAN SOLAR CS3N-400MS [BLK] <br />MODULE DIMENSIONS: (L/W/H) 76.40"/41.30"/1.38" <br />INVERTER: (15) ENPHASE ENERGY IQ8PLUS-72-2-US [240V] <br />INTERCONNECTION METHOD: BACKFEED IN MSP <br />UTILITY COMPANY: SCE <br />PHOTOVOLTAIC SYSTEM SPECIFICATIONS: <br />SCALE: 1/16" = 1'-0" <br />1 PLOT PLAN <br />CS <br />SHEET INDEX <br />CS COVER SHEET <br />A1.0 SITE PLAN <br />A2.0 MOUNTING DETAILS <br />E1.0 NOTES <br />E2.0 ELECTRICAL LINE DIAGRAM <br />P1.0 WARNING LABELS <br />SS1+ EQUIPMENT SPECIFICATIONS <br />PR <br />O <br />P <br />E <br />R <br />T <br />Y <br /> <br />LI <br />NE <br /> <br />21 <br />3 <br />7 <br /> <br /> N <br /> <br />S <br />P <br />R <br />U <br />C <br />E <br /> <br />S <br />T <br />FR <br />O <br />N <br />T <br /> <br />O <br />F <br /> <br />H <br />O <br />U <br />S <br />E <br />M <br />EXISTING EXTERIOR MAIN <br />SERVICE PANEL & POINT OF <br />INTERCONNECTION TIED TO <br />EXTERIOR UTILITY METER <br />MAIN <br />HOUSE <br />FENCE <br />ROOF ACCESS POINT <br />DRIVEWAY <br />ROOF #1 <br />(05) CANADIAN SOLAR CS3N-400MS [BLK] <br />SLOPE: 15° <br />AZIM.: 270° <br />NOTE <br />-NO ACTIVE FIRE SPRINKLER. <br />-NOTIFY SERVING UTILITY BEFORE ACTIVATION OF PV SYSTEM <br />-DO NOT COVER MECHANICAL AND PLUMBING VENTS ON THE ROOF <br />WITH SOLAR PV PANELS. <br />-A ROOF ACCESS POINT SHOULD BE PROVIDED THAT DOES NOT PLACE <br />A GROUND LADDER OVER AN OPENING SUCH AS A WINDOW OR DOOR. <br />LOCATED AT A SOLID POINT IN THE BUILDING CONSTRUCTION AND IN <br />THE LOCATIONS WHERE THE ACCESS POINT DOES NOT CONFLICT WITH <br />OVERHEAD OBSTRUCTIONS SUCH AS TREE LIMBS, WIRES, OR SIGNS. <br />EXISTING ATTACHED/DETACHED <br />STRUCTURE NO ELECTRICAL <br />PR <br />O <br />P <br />E <br />R <br />T <br />Y <br /> <br />LINE <br />PROPERTY LINE <br />PROPERTY LINE <br />"NOTE- ALL ROOF PENETRATIONS WILL BE SEALED AND MADE <br />WEATHER TIGHT WITH APPROVED MATERIALS. <br />NOTE- THERE IS NO OBSTRUCTION OR INTERFERENCE WITH THE <br />FUNCTION OF PLUMBING VENTS OR MECHANICAL EQUIPMENT, WITH A <br />6 INCH MINIMUM OF SEPARATION. THERE WILL BE NO OBSTRUCTIONS <br />AND MINIMUM CLEARANCES IS MAINTAINED." <br />PATHWAY <br />ROOF #2 <br />(08) CANADIAN SOLAR CS3N-400MS [BLK] <br />SLOPE: 15° <br />AZIM.: 270° <br />ROOF #3 <br />(02) CANADIAN SOLAR CS3N-400MS [BLK] <br />SLOPE: 15° <br />AZIM.: 180° <br />2137 N Spruce St <br />06/02/23
The URL can be used to link to this page
Your browser does not support the video tag.