OWNER <br />SHEET TITLE <br />SHEET NUMBER <br />PROJECT TITLE <br />HUYNH <br />RESIDENCE <br />CONTRACTOR <br />TITAN SOLAR POWER CA INC <br />525 W BASELINE ROAD <br />MESA, AZ 85210 <br />(855) 729-7652 <br />WWW.TITANSOLARPOWER.COM <br />PROJECT ID# TSP145775 <br />DATE DESCRIPTION <br />6.252 KW CEC-AC RATING <br />STRING INVERTER SYSTEM <br />JOBSITE ADDRESS <br />2229 <br />S LAURA LINDA LN <br />SANTA ANA, <br />CA 92704 <br />REVISION <br />DATE <br />DRAWN10-23-22 <br />DESIGN BY: RD <br />CAD <br />F O R C A L I I N C . <br />SHELLEY V CALUAG <br />cadforcali@gmail.com <br />323-698-4207 <br />SP: Clean Skies Technologies <br />E3 <br />REQUIRED <br />SIGNAGE <br />SIGNS AND LABEL - CENTRAL/STRING INVERTER SYSTEMS <br />CEC ARTICLES 690 AND 705 AND CA RESIDENTIAL CODE SECTION R324 REQUIRE THE FOLLOWING <br />LABELS OR MARKINGS BE INSTALLED AT THESE COMPONENTS OF THE PHOTOVOLTAIC SYSTEM: <br />DIRECTORY PLACARD <br />· ALL INTERIOR AND EXTERIOR DC CONDUIT, ENCLOSURES, RACEWAYS, CABLE ASSEMBLIES, JUNCTION <br />BOXES, COMBINER BOXES AND DISCONNECTS ARE MARKED. <br />· THE MARKINGS ON THE CONDUITS, RACEWAYS AND CABLE ASSEMBLIES ARE EVERY 10 FEET, WITHIN <br />ONE FOOT OF ALL TURNS OR BENDS AND WITHIN ONE FOOT ABOVE AND BELOW ALL PENETRATIONS <br />OF ROOF/CEILING ASSEMBLIES, WALLS AND BARRIERS. <br />· MARKING IS PLACED ADJACENT TO THE MAIN SERVICE DISCONNECT IN A LOCATION CLEARLY VISIBLE <br />FROM WHERE THE DISCONNECT IS OPERATED. <br />· THE MARKINGS SAY WARNING: PHOTOVOLTAIC POWER SOURCE <br />AND HAVE 3/8-INCH (9.5 MM) MINIMUM-SIZED WHITE LETTERS ON A RED BACKGROUND. THE SIGNS ARE <br />MADE OF REFLECTIVE WEATHER RESISTANT MATERIAL. <br />· WHERE PV CIRCUITS ARE EMBEDDED IN BUILT-UP, LAMINATE OR MEMBRANE ROOFING MATERIALS IN <br />ROOF AREAS NOT COVERED BY PV MODULES AND ASSOCIATED EQUIPMENT, THE LOCATION OF <br />CIRCUITS SHALL BE CLEARLY MARKED. <br />· REQUIRED LABELS SHALL BE PERMANENT AND SUITABLE FOR THE ENVIRONMENT. <br />SIGNAGE NOTES: <br />K <br />MAIN SERVICE <br />PANEL <br />6" <br />5" <br />INVERTER <br />CAUTION <br />POWER TO THIS BUILDING ALSO SUPPLIED <br />FROM THE FOLLOWING SOURCES WITH <br />DISCONNECTS AS SHOWN <br />S <br />L <br />A <br />U <br />R <br />A <br /> <br />L <br />I <br />N <br />D <br />A <br /> <br />L <br />N <br />DR <br />I <br />VE <br />W <br />A <br />Y <br />AC DISCO <br />ADDRESS: 2229 S LAURA LINDA LANE <br />INVERTER <br />DC <br />DISCO <br />PV ARRAY <br />JBOX <br />A A <br />GC <br />M <br />MAIN SERVICE <br />PANELAC <br />DISCO <br />C G <br />I JH E F <br />DC B <br />K <br />NEC 690.13(B) <br />I <br />J <br />D <br />RATED AC OUTPUT CURRENT <br />NORMAL OPERATING VOLTAGE <br />A <br />V <br />NEC 690.54 <br />PHOTOVOLTAIC AC DISCONNECT <br />NEC 690.56 (C)(3) <br />RAPID SHUTDOWN SWITCH <br />FOR SOLAR PV SYSTEM <br />REQUIRED AT LOCATION ON OR NO <br />MORE THAN 1 METER (3 FT) FROM THE <br />SWITCH <br />25 <br />240 SOLAR PV SYSTEM EQUIPPED <br />WITH RAPID SHUTDOWN <br />TURN RAPID SHUTDOWN <br />SWITCH TO THE <br />"OFF" POSITION TO <br />SHUTDOWN PV SYSTEM <br />AND REDUCE <br />SHOCK HAZARD <br />IN THE ARRAY <br />SOLAR ELECTRIC <br />PV PANELS <br />NEC 690.56(C)(1) <br />WARNING: PHOTOVOLTAIC <br />POWER SOURCE <br />NEC 705.12 (B)(2)(c) <br />A <br />NEC 690.31(G)(3)(4) <br />F <br />C <br />E <br />B <br />!PV SYSTEM <br />DISCONNECT <br />G <br />NEC 690.13(B) <br />MAIN PHOTOVOLTAIC <br />SYSTEM DISCONNECT <br />NEC 705.12(B)(3-4) & NEC 690.59 <br />POWER SOURCE OUTPUT CONNECTION <br />DO NOT RELOCATE THIS <br />OVERCURRENT DEVICE <br />WARNING ! ! <br />WARNING ! ! <br />TERMINAL ON THE LINE AND <br />LOAD SIDES MAY BE ENGERGIZED <br />IN THE OPEN POSITION <br />ELECTRIC SHOCK HAZARD <br />DIRECT CURRENT <br />PHOTOVOLTAIC <br />POWER SOURCE <br />MAXIMUM VOLTAGE <br /> VDC <br />MAXIMUM CIRCUIT CURRENT <br /> AMPS <br />MAXIMUM RATED <br />DC TO DC CONVERTER OUTPUT <br /> AMPS <br />NEC 690.53 <br />480 <br />16.5 <br />15 <br />H <br />WARNING ! ! <br />SOURCES: UTILITY GRID AND <br />PV SOLAR ELECTRIC SYSTEM <br />DUAL POWER SUPPLY <br />IF THERE IS NO INVERTER PLACE LABEL ON <br />COMBINER BOX, IF THERE IS NO COMBINER BOX <br />PLACE ON MAIN SERVICE PANEL. <br />DIRECTORY <br />PLACARD <br />K <br />ALL ROOF CONDUIT <br />NEC 705.10 & NEC 690.56(B) <br />REQUIRES A PERMANENT PLAQUE <br />OR DIRECTORY DENOTING ALL <br />ELECTRIC POWER SOURCE ON OR <br />IN THE PREMISES OR RAPID FIRE <br />SHUTDOWN EQUIPMENT; INSTALL <br />AT MAIN SERVICE PANEL <br />SOLAR <br />ARRAYS <br />2229 S Laura Linda <br />Ln12/21/22