Laserfiche WebLink
L1 <br />L2 <br />SOURCE CIRUIT #1 <br />SOURCE CIRUIT #2 <br />SOURCE CIRUIT #3 <br />L1 <br />L2 <br />L1 <br />L2 <br />1 <br />EXISTING <br />6 MODULES <br />X21-350-BLK-E-AC <br />SUNPOWER <br />12 EXISTING MODULES <br />SPR-X22-360-E-AC <br />SUNPOWER <br />11 EXISTING MODULES <br />SPR-X22-360-E-AC <br />SUNPOWER <br />NEMA 3R, <br />240VAC <br />JUNCTION BOX <br />L1L2N <br />2 <br />(E)20A <br />(E)20A <br />(N)20A <br />CONDUIT MUST BE <br />SUPPORTED A MINIMUM <br />OF 7/8" ABOVE THE ROOF <br />SURFACE. <br />EXISTING (E)LOAD CENTER <br /> BUS RATED <br />240 VAC, 1Ø <br />SUNPOWER <br />(E)15A <br />(3) #12 THWN <br />(1) #12 THWN EGC <br />(E)SUNPOWER <br />PVS6 MONITORING <br />125A <br />MLO <br />3 <br />L1L2N <br />MLO <br /> SUBPANEL <br /> BUS RATED <br />240 VAC, 1Ø <br />EX <br />I <br />S <br />T <br />I <br />N <br />G <br />125A <br />(N)50A <br />(E) <br />L1L2N <br /> MAIN SERVICE PANEL <br /> BUS RATED <br />SPLIT BUS <br />240 VAC, 1Ø, 3W <br />NOTE: THE PV BREAKER IS THE MAIN <br />DISCONNECTING MEANS. <br />(E) <br />200A <br />100A <br /> 100A <br />M <br />UTILITY METER <br />NO. <br />222013-568064 <br />UN <br />D <br />E <br />R <br />G <br />R <br />O <br />U <br />N <br />D <br />SE <br />R <br />V <br />I <br />C <br />E <br />NOTE: <br />PHOTOVOLTAIC MODULE HAS AN <br />INTEGRATED MICROINVERTER. <br />MAX PV BREAKER: <br />125A x 120% - 100 = 50A <br />CONDUCTOR AND CONDUIT SCHEDULE <br />TAG CONDUCTOR CURRENT CARRYING <br />CONDUCTORS IN CONDUIT EGC CONDUIT OCPD <br />1 <br />2 <br />3 <br />12 AWG PV WIRE, COPPER <br />10 AWG THWN-2, COPPER <br />8 AWG THWN-2, COPPER <br />N/A <br />2 <br />3 <br />6 AWG BARE, COPPER <br />8 AWG THWN-2, COPPER <br />FREE AIR <br />3/4" DIA. EMT <br />3/4" DIA. EMT <br />N/A <br />20A <br />50A <br />USE SUNPOWER INTEGRATED GROUNDING TO <br />GROUND ALL MODULES, JUNCTION BOXES AND <br />ANY OTHER METAL PARTS AND GROUND LUGS <br />WITH #6 AWG SOLID COPPER WHERE NEEDED <br />NOTE: <br />THE INVISIMOUNT SYSTEM IS LISTED TO UL2703 FOR <br />INTEGRATED GROUNDING; SUNPOWER AC MODULES ARE A <br />BONDING COMPONENT AND ARE LISTED TO UL1741. <br />INSTALLING SUNPOWER AC MODULES ON THE INVISIMOUNT <br />SYSTEM (OR ANY MOUNTING SYSTEM THAT IS LISTED TO <br />UL2703 FOR BONDING-NOT JUST FOR FIRE CLASSIFICATION), <br />NO ADDITIONAL GROUNDING HARDWARE, LUGS, OR COPPER <br />WIRE ARE REQUIRED ON THE ROOF. SEE INVISIMOUNT <br />SPECSHEET PAGES WITHIN THIS PLAN SET. <br />8 AWG THWN-2, COPPER <br />EXISTING BUILDING <br />GROUNDING <br />ELECTRODE SYSTEM <br />EXISTING <br />ECOSOLAR USA <br />ELECTRICAL LLC <br />13962 SEABOARD CIRCLE <br />GARDEN GROVE, CA 92840 <br />PH: 714.265.9077 <br />SCOPE OF WORK: <br />DAVID Q HOANG C10 - 1045300 <br />DATE: <br />DRAWN BY: <br />HOMEOWNER: <br />ADDRESS: <br />CHECKED BY: <br />R.A. <br />S.C.INSTALL (6) SUNPOWER X21-350-BLK-E-AC ELECTRIC MODULES ON THE EXISTING 2-STORY <br />W-TILE ROOF. INSTALL ASSOCIATED MOUNTING HARDWARE, JUNCTION BOXES, CONDUIT, <br />CONDUCTORS AND GROUNDING. INSTALL A NEW 20A BREAKER IN THE EXISTING LOAD <br />CENTER AND CONNECT TO THE ADDITIONAL 6 NEW MODULES. THE EXISTING 40A PV <br />BREAKER WILL BE REPLACE BY A NEW 50A BREAKER. <br />SANG PHAM <br />714.616.6620 <br />03.08.2023 <br />2305 HUCKLEBERRY RD. <br />SANTA ANA, CA 92706 <br />PV2 <br />ELECTRICAL LINE DIAGRAM <br />2305 W <br />Huckleberry05/18/23