PROJECT NAME <br />SHEET TITLE <br />SHEET NUMBER <br />PROJECT TITLE <br />JOBSITE ADDRESS <br />DIAZ <br />RESIDENCE <br />5.200 DC KW <br />4.781 KW CEC-AC RATING <br />STRING INVERTER SYSTEM <br />2238 <br />WEST HARVARD ST <br />SANTA ANA, <br />CA 92704 <br />CONTRACTOR <br />TITAN SOLAR POWER CA INC <br />525 W BASELINE ROAD <br />MESA, AZ 85210 <br />(855) 729-7652 <br />WWW.TITANSOLARPOWER.COM <br />PROJECT ID# TSP146826 <br />DATE DESCRIPTION <br />REVISION <br />DATE <br />DRAWN10-31-22 <br />DESIGN BY: <br />CAD <br />F O R C A L I I N C . <br />SHELLEY V CALUAG <br />cadforcali@Jmail.com <br />323-698-4207 <br />SP: Ascend Energy <br />RD <br />A0 <br />PROJECT INFO <br />VICINITY MAP <br />PV NOTES <br />VICINITY MAP <br />PROJECT SITE <br />OWNER: MARIA GUADALUPE DIAZ <br />ADDRESS:2238 WEST HARVARD ST <br />SANTA ANA, CA 92704 <br />PHONE: (951) 556-2149 <br />EMAIL: mariaflores090973@icloud.com <br />APN:40838619 <br />(ORANGE COUNTY) <br />UTILITY: SCE <br />AERIAL VIEW <br />5.200 DC kW SOLAR PV STRING INVERTER SYSTEM - ROOF MOUNT <br />DIAZ RESIDENCE <br />2238 WEST HARVARD ST SANTA ANA, CA 92704 <br />OCCUPANCY: R3-SFD CONSTRUCTION TYPE: VB <br /># OF STORIES: 1 BLDG AREA (SQFT):1513 <br />SPRINKLERS: NONE ROOF AREA (SQFT): 2783 <br />ENGINEERING CRITERIA FOR RACKING <br />DESIGN WIND SPEED: 110 MPH <br />WIND EXPOSURE CATEGORY: B <br />GROUND SNOW LOAD: 0 PSF <br />SOLAR PHOTOVOLTAIC SYSTEM NOTES <br />1. ALL EQUIPMENT SHALL BE LISTED AND LABELED BY A RECOGNIZED TESTING LABORATORY AND INSTALLED PER THE LISTING <br />REQUIREMENTS AND THE MANUFACTURER'S INSTRUCTIONS, CEC 110.2, 110.3, 690.4(B) AND 690.12(D). <br />2. ALL OUTDOOR EQUIPMENT SHALL BE NEMA 3R RATED, INCLUDING ALL ROOF MOUNTED TRANSITION BOXES AND SWITCHES. <br />3. ALL EQUIPMENT SHALL BE PROPERLY GROUNDED AND BONDED IN ACCORDANCE WITH CEC ARTICLE 250. <br />4. ALL PV CIRCUITS CONNECTED TO MORE THAN ONE SOURCE SHALL HAVE PROTECTION AGAINST OVERCURRENT PER CEC <br />690.9. <br />5. DISCONNECTING MEANS OF THE PV SYSTEM (INCLUDING RAPID SHUTDOWN INITIATION) SHALL BE LOCATED IN READILY <br />ACCESSIBLE LOCATION NEAR THE EQUIPMENT, CEC 690.13, 690.15. <br />6. ENERGY STORAGE SYSTEMS TERMINALS LOCATED MORE THAN 5 FEET AWAY OR ON OPPOSITE SIDE OF WALL FROM <br />CONNECTED EQUIPMENT MUST HAVE DISCONNECTING MEANS IN ACCORDANCE WITH CEC 706.7(E) AND LABELED PER <br />706.7(D). A SECOND DISCONNECTING MEANS LOCATED AT THE CONNECTED EQUIPMENT SHALL BE INSTALLED WHERE THE <br />DISCONNECTING MEANS AT THE ESS END OF THE CIRCUIT IS NOT WITHIN SIGHT. <br />7. RAPID SHUTDOWN EQUIPMENT TO COMPLY WITH CEC 690.12. <br />8. THE UTILITY-INTERACTIVE INVERTERS SHALL AUTOMATICALLY DE-ENERGIZE ITS OUTPUT TO THE CONNECTED ELECTRICAL <br />PRODUCTION AND DISTRIBUTION NETWORK UPON LOSS OF VOLTAGE IN THE SYSTEM AND SHALL REMAIN IN THAT STATE <br />UNTIL THE ELECTRICAL PRODUCTION AND DISTRIBUTION NETWORK VOLTAGE HAS BEEN RESTORED, CEC 705.40. <br />9. ALL CONDUCTORS IN EXPOSED OUTDOOR LOCATIONS SHALL BE LISTED AND IDENTIFIED FOR USE IN DIRECT SUNLIGHT AND <br />FOR THE APPLICATION. CEC310.10(D) AND 690.31(C) THROUGH (F). <br />10. INSULATION OF EXPOSED CONDUCTORS UNDER THE MODULES SHALL BE USE-2 OR PV-WIRE TYPE FOR PV SYSTEMS, CEC <br />690.31(C). <br />11. FINE-STRANDED CABLE CONNECTIONS MUST BE MADE IN LUGS AND TERMINALS LISTED AND MARKED FOR THE USE, CEC <br />110.14. <br />12. ALL PV CIRCUIT CONDUCTORS SHALL BE MARKED ON EACH END AND GROUPED FOR UNIQUE IDENTIFICATION, CEC <br />690.31(B). <br />13. ALL GROUNDED, (NEUTRAL), CONDUCTORS' INSULATION SHALL BE SOLID WHITE, GRAY, OR WITH 3-WHITE STRIPES, CEC <br />200.6, 200.7, & 400.22; AND ALL GROUNDING CONDUCTORS SHALL BE OF BARE WIRE WITHOUT COVERING, OR WITH <br />INSULATION OF GREEN OR GREEN WITH YELLOW STRIPES, CEC 250.119 & 400.23. THE COLOR OF UNGROUNDED <br />CONDUCTORS SHALL BE OTHER THAN FOR GROUNDED, (NEUTRAL), AND GROUNDING CONDUCTORS, CEC 310.110(C). <br />14. MAXIMUM CONDUCTOR LENGTH BETWEEN SUPPLY SIDE CONNECTION AND OVERCURRENT PROTECTION IS 10 FEET, CEC <br />705.31. <br />15. CONNECTIONS ON THE LOAD SIDE OF THE SERVICE DISCONNECTING MEANS OF THE OTHER SOURCE(S) AT ANY <br />DISTRIBUTION EQUIPMENT ON THE PREMISES SHALL MEET THE FOLLOWING, CEC 705.12(B). <br />16. DC WIRING INSIDE A BUILDING MUST BE IN METALLIC TYPE RACEWAYS, CONDUITS, ENCLOSURES, OR CABLE SHEATHINGS, <br />CEC 690.31(G). <br />17. METALLIC TYPE RACEWAYS, CONDUITS, ENCLOSURES, AND CABLE SHEATHS CONTAINING CIRCUITS OVER 250-VOLTS TO <br />GROUND MUST BE BONDED IN ACCORDANCE WITH CEC 250.97. <br />18. ALL EXTERIOR CONDUIT, FITTINGS AND BOXES SHALL BE RAIN TIGHT AND APPROVED FOR USE IN WET LOCATIONS, CEC <br />314.15 <br />19. FLEXIBLE, FINE-STRANDED CABLES SHALL BE TERMINATED ONLY WITH TERMINALS, LUGS, DEVICES OR CONNECTOR THAT <br />ARE IDENTIFIED AND LISTED FOR SUCH USE, CEC 690.31(H) & 110.14. <br />20. CONNECTORS SHALL BE OF LATCHING OR LOCKING TYPE. CONNECTORS THAT ARE READILY ACCESSIBLE AND OPERATING <br />AT OVER 30 VOLTS SHALL REQUIRE TOOL TO OPEN AND MARKED “DO NOT DISCONNECT UNDER LOAD” OR “NOT FOR <br />CURRENT INTERRUPTING”, CEC 690.33(C) & (E)(2). <br />21. EQUIPMENT GROUNDING CONDUCTOR FOR PV MODULES SMALLER THAN 6 AWG SHALL BE PROTECTED FROM PHYSICAL <br />DAMAGE BY A RACEWAY OR CABLE ARMOR, CEC 690.46 & 250.120(C). <br />22. THE INTERCONNECTION POINT SHALL BE ON THE SUPPLY SIDE OF ALL GROUND-FAULT PROTECTION EQUIPMENT, CEC <br />705.32. <br />23. CABLES/WIRES THAT ARE SUBJECT TO PHYSICAL DAMAGE, SUCH AS THOSE NOT LOCATED UNDER THE MODULES, MUST BE <br />PROTECTED, CEC 300.4. <br />24. PROPOSED LOCATIONS OF ELECTRICAL SERVICE REPLACEMENTS MUST ALSO BE APPROVED BY THE ELECTRICAL UTILITY <br />COMPANY. <br />25. FOR ELECTRICAL SERVICE REPLACEMENTS, BONDING TO THE METAL PIPES OF NATURAL GAS, HOT WATER, AND COLD <br />WATER MUST BE PROVIDE, CEC 250.104. <br />26. GROUNDING ROD ELECTRODES SHALL BE MINIMUM 5/8’’ IN DIAMETER AND INSTALLED 8’ MINIMUM IN CONTACT WITH SOIL, <br />CEC 250.52(A)(5), 250.53(G). <br />27. MINIMUM 7/8’’ CLEARANCE FROM ROOF TO BOTTOM OF CONDUIT OR USE A TEMPERATURE ADDER OF 33 DEGREES C. CEC <br />310.15(B)(3)(C) <br />28. EXISTING PLUMBING VENTS, SKYLIGHTS, EXHAUST OUTLETS, & VENTILATIONS INTAKE AIR OPENINGS SHALL NOT BE COVERED <br />OR BLOCKED BY THE SOLAR PHOTOVOLTAIC SYSTEM. <br />29. EXISTING DWV PLUMBING VENT TERMINATIONS THAT ARE HORIZONTALLY LOCATED CLOSER THAN 12" FROM THE PROPOSED <br />MODULES, MUST BE REROUTED, OR MUST BE EXTENDED A MINIMUM OF 6" ABOVE THE SURFACE OF THE MODULES, CPC <br />906.1. <br />30. EXISTING B-VENT TERMINATIONS, FOR FUEL BURNING APPLIANCES, WHERE ADJACENT TO THE PROPOSED MODULES, MUST <br />BE EXTENDED 12" ABOVE THE MODULES' TOP SURFACE, CMC 802.6.1(1) & CPC 509.6.1(1). <br />31. THE MARKINGS, "WARNING: PHOTOVOLTAIC POWER SOURCE", FOR DC RACEWAYS AND CABLE ASSEMBLIES MUST BE AT 10' <br />O.C.; AND BENDS, ABOVE OR BELOW PENETRATIONS OF ROOFS, CEILINGS, WALLS, OR BARRIERS, CEC 690.31(G)(4). <br />32. PV COMBINER PANELBOARDS MUST HAVE PERMANENT MARKINGS INDICATING THAT THEY ARE DEDICATED FOR PV CIRCUITS <br />ONLY NO LOADS ARE TO BE CONNECTED. <br />33. WORKING CLEARANCES TO BE PROVIDED AT NEW AND EXISTING ELECTRICAL EQUIPMENT, CEC 110.26. <br />34. A LADDER MUST BE PROVIDED FOR INSPECTIONS IN ACCORDANCE WITH CAL-OSHA REGULATIONS, SECURED AND EXTENDING <br />3' ABOVE THE ROOF. <br />35. ALL OF THE REQUIRED MARKINGS, SIGNS, AND LABELS MUST BE INSTALLED ON ALL EQUIPMENT PRIOR TO ANY INSPECTIONS. <br />36. LABELS SHALL BE REFLECTIVE, AND ALL LETTERS SHALL BE CAPITALIZED AND SHALL BE A MINIMUM HEIGHT OF 3/8'' IN <br />WHITE ON A RED BACKGROUND. CEC 690.31(G)(4) <br />37. IDENTIFICATION OF POWER SOURCE RAPID SHUTDOWN AND LABELING SHALL BE IN ACCORDANCE WITH CEC 690.56(C). <br />38. WHEN THE MAIN CIRCUIT BREAKER IS DERATED, A PERMANENT MARKING MUST BE PROVIDED ON THE PANELBOARD TO <br />INDICATE THAT THE MAIN CIRCUIT BREAKER HAS BEEN DOWNSIZED TO _______ AMPS, DO NOT UPSIZE IT. <br />39. PANELS AND MODULES NOT TO BE INSTALLED ON ROOF BELOW AN EMERGENCY ESCAPE AND RESCUE OPENING. CRC <br />R324.6.2.2 <br />40. GROUND-MOUNTED PV SYSTEMS MUST HAVE A CLEAR, BRUSH-FREE AREA OF 10-FEET AND A FIRE SEPARATION DISTANCE OF <br />5-FEET MINIMUM TO OTHER STRUCTURES AND PROPERTY LINES, CRC R324.7 & R302.1. <br />41. PLAN CHECK AND PERMIT FOR PV SYSTEM AND ASSOCIATED EQUIPMENT ONLY. <br />42. ALL PROJECTS SUBJECT TO FIELD VERIFICATION FOR CODE COMPLIANCE. <br />43. APPROVED SMOKE AND CARBON MONOXIDE ALARMS ARE REQUIRED WITHIN THE DWELLING UNIT AND SHALL BE <br />FIELD VERIFIED EITHER THROUGH FINAL BUILDING INSPECTION. SMOKE ALARMS ARE REQUIRED TO BE INSTALLED IN <br />ALL BEDROOMS, OUTSIDE EACH BEDROOM, AND AT LEAST ONE ON EACH FLOOR OF THE HOUSE. CARBON MONOXIDE <br />ALARMS ARE REQUIRED OUTSIDE EACH BEDROOM AND AT LEAST ONE ON EACH FLOOR OF THE HOUSE. R314.1, <br />R315.1 <br />44. NOTIFY SERVING UTILITY BEFORE ACTIVATION OF PV SYSTEM. <br />APPLICABLE CODES <br />ALL MATERIALS, EQUIPMENT, INSTALLATION AND WORK <br />SHALL COMPLY WITH THE FOLLOWING APPLICABLE CODES <br />2019 CA BUILDING CODES (CBC) <br />2019 CA RESIDENTIAL CODES (CRC) <br />2019 CA MECHANICAL CODES (CMC) <br />2019 CA PLUMBING CODES (CPC) <br />2019 CA FIRE CODES (CFC) <br />2019 CA ELECTRICAL CODES (CEC) <br />2019 CA ENERGY CODES (CEnC) <br />2019 CALIFORNIA GREEN BUILDING STANDARDS CODE <br />(CALGreen) <br />SHEET INDEX <br />A0 PROJECT INFO, VICINITY MAP, PV NOTES <br />A1 SITE PLAN <br />A2 MOUNTING ROOF PLAN <br />E1 SINGLE LINE DIAGRAM <br />E2 ELECTRICAL CALCULATIONS <br />E3 REQUIRED SIGNAGE <br />E4 - E4.1 MODULE DATA SHEET & CERTIFICATION <br />E5 - E5.1 INVERTER DATA SHEET & CERTIFICATION <br />E6 OPTIMIZER DATA SHEET <br />S1 STANCHION DATA SHEET <br />S2 RACKING DATA SHEET <br />S3 - S3.3 RACKING ENGINEERING <br />S4 RACKING GROUNDING <br />S5 RACKING CERTIFICATION <br />MAIN SERVICE PANEL INFORMATION <br />EXISTING: NO UPGRADE: YES <br />BUS RATING: (N)225A MAIN BREAKER SIZE: (N)200A <br />PHASE: 1PH MB POSITION: TOP <br /># OF WIRES: 3 DERATE?: NO <br />VOLTAGE: 240V DERATE SIZE: N/A <br />UTILITY FED: OH <br />METER#: 222013-607211 <br />PROJECT SCOPE <br />INSTALLATION OF ROOF MOUNT SOLAR PV SYSTEM <br />NEW UPGRADE 225A MAIN SERVICE PANEL <br />PV EQUIPMENT QTY MODEL NO AND MANUFACTURER <br />MODULES:13 Q.PEAK DUO BLK ML-G10 400 <br />HANWHA Q CELL MODULES <br />OPTIMIZERS:1 3 P401 SOLAREDGE OPTIMIZERS <br />INVERTER:1 SE5000H-US (240V) >SI1 @ <br />SOLAREDGE HD INVERTER <br />SYSTEM SIZE:5.200 DC kW RATING <br />4.781 CEC AC RATING <br />ARRAY AREA:21 .1 4 SQFT x 1 3 =274.76 SQFT <br />PROJECT SITE <br />STRUCTURAL ONLY <br />www.vincise.com <br />S T R U C T U R A L E N G I N E E R S <br />12.13.2022 <br />***The scope of the plans is for the installation of <br />the solar photovoltaic system only and the <br />approval is subject to compliance with all <br />applicable city and state codes and regulations <br />regarding construction. The approval of the plans <br />does not constitute any certification of the <br />accuracy, completeness, or building permit status <br />of the existing buildings and structures as shown. <br />*** <br />Bldg permit #101113461 <br />Elect permit #20178423 <br />Issued on 1/25/23 <br />2238 W Harvard St <br />01/30/23