PROJECT NAME
<br />SHEET TITLE
<br />SHEET NUMBER
<br />PROJECT TITLE
<br />JOBSITE ADDRESS
<br />DIAZ
<br />RESIDENCE
<br />5.200 DC KW
<br />4.781 KW CEC-AC RATING
<br />STRING INVERTER SYSTEM
<br />2238
<br />WEST HARVARD ST
<br />SANTA ANA,
<br />CA 92704
<br />CONTRACTOR
<br />TITAN SOLAR POWER CA INC
<br />525 W BASELINE ROAD
<br />MESA, AZ 85210
<br />(855) 729-7652
<br />WWW.TITANSOLARPOWER.COM
<br />PROJECT ID# TSP146826
<br />DATE DESCRIPTION
<br />REVISION
<br />DATE
<br />DRAWN10-31-22
<br />DESIGN BY:
<br />CAD
<br />F O R C A L I I N C .
<br />SHELLEY V CALUAG
<br />cadforcali@Jmail.com
<br />323-698-4207
<br />SP: Ascend Energy
<br />RD
<br />A0
<br />PROJECT INFO
<br />VICINITY MAP
<br />PV NOTES
<br />VICINITY MAP
<br />PROJECT SITE
<br />OWNER: MARIA GUADALUPE DIAZ
<br />ADDRESS:2238 WEST HARVARD ST
<br />SANTA ANA, CA 92704
<br />PHONE: (951) 556-2149
<br />EMAIL: mariaflores090973@icloud.com
<br />APN:40838619
<br />(ORANGE COUNTY)
<br />UTILITY: SCE
<br />AERIAL VIEW
<br />5.200 DC kW SOLAR PV STRING INVERTER SYSTEM - ROOF MOUNT
<br />DIAZ RESIDENCE
<br />2238 WEST HARVARD ST SANTA ANA, CA 92704
<br />OCCUPANCY: R3-SFD CONSTRUCTION TYPE: VB
<br /># OF STORIES: 1 BLDG AREA (SQFT):1513
<br />SPRINKLERS: NONE ROOF AREA (SQFT): 2783
<br />ENGINEERING CRITERIA FOR RACKING
<br />DESIGN WIND SPEED: 110 MPH
<br />WIND EXPOSURE CATEGORY: B
<br />GROUND SNOW LOAD: 0 PSF
<br />SOLAR PHOTOVOLTAIC SYSTEM NOTES
<br />1. ALL EQUIPMENT SHALL BE LISTED AND LABELED BY A RECOGNIZED TESTING LABORATORY AND INSTALLED PER THE LISTING
<br />REQUIREMENTS AND THE MANUFACTURER'S INSTRUCTIONS, CEC 110.2, 110.3, 690.4(B) AND 690.12(D).
<br />2. ALL OUTDOOR EQUIPMENT SHALL BE NEMA 3R RATED, INCLUDING ALL ROOF MOUNTED TRANSITION BOXES AND SWITCHES.
<br />3. ALL EQUIPMENT SHALL BE PROPERLY GROUNDED AND BONDED IN ACCORDANCE WITH CEC ARTICLE 250.
<br />4. ALL PV CIRCUITS CONNECTED TO MORE THAN ONE SOURCE SHALL HAVE PROTECTION AGAINST OVERCURRENT PER CEC
<br />690.9.
<br />5. DISCONNECTING MEANS OF THE PV SYSTEM (INCLUDING RAPID SHUTDOWN INITIATION) SHALL BE LOCATED IN READILY
<br />ACCESSIBLE LOCATION NEAR THE EQUIPMENT, CEC 690.13, 690.15.
<br />6. ENERGY STORAGE SYSTEMS TERMINALS LOCATED MORE THAN 5 FEET AWAY OR ON OPPOSITE SIDE OF WALL FROM
<br />CONNECTED EQUIPMENT MUST HAVE DISCONNECTING MEANS IN ACCORDANCE WITH CEC 706.7(E) AND LABELED PER
<br />706.7(D). A SECOND DISCONNECTING MEANS LOCATED AT THE CONNECTED EQUIPMENT SHALL BE INSTALLED WHERE THE
<br />DISCONNECTING MEANS AT THE ESS END OF THE CIRCUIT IS NOT WITHIN SIGHT.
<br />7. RAPID SHUTDOWN EQUIPMENT TO COMPLY WITH CEC 690.12.
<br />8. THE UTILITY-INTERACTIVE INVERTERS SHALL AUTOMATICALLY DE-ENERGIZE ITS OUTPUT TO THE CONNECTED ELECTRICAL
<br />PRODUCTION AND DISTRIBUTION NETWORK UPON LOSS OF VOLTAGE IN THE SYSTEM AND SHALL REMAIN IN THAT STATE
<br />UNTIL THE ELECTRICAL PRODUCTION AND DISTRIBUTION NETWORK VOLTAGE HAS BEEN RESTORED, CEC 705.40.
<br />9. ALL CONDUCTORS IN EXPOSED OUTDOOR LOCATIONS SHALL BE LISTED AND IDENTIFIED FOR USE IN DIRECT SUNLIGHT AND
<br />FOR THE APPLICATION. CEC310.10(D) AND 690.31(C) THROUGH (F).
<br />10. INSULATION OF EXPOSED CONDUCTORS UNDER THE MODULES SHALL BE USE-2 OR PV-WIRE TYPE FOR PV SYSTEMS, CEC
<br />690.31(C).
<br />11. FINE-STRANDED CABLE CONNECTIONS MUST BE MADE IN LUGS AND TERMINALS LISTED AND MARKED FOR THE USE, CEC
<br />110.14.
<br />12. ALL PV CIRCUIT CONDUCTORS SHALL BE MARKED ON EACH END AND GROUPED FOR UNIQUE IDENTIFICATION, CEC
<br />690.31(B).
<br />13. ALL GROUNDED, (NEUTRAL), CONDUCTORS' INSULATION SHALL BE SOLID WHITE, GRAY, OR WITH 3-WHITE STRIPES, CEC
<br />200.6, 200.7, & 400.22; AND ALL GROUNDING CONDUCTORS SHALL BE OF BARE WIRE WITHOUT COVERING, OR WITH
<br />INSULATION OF GREEN OR GREEN WITH YELLOW STRIPES, CEC 250.119 & 400.23. THE COLOR OF UNGROUNDED
<br />CONDUCTORS SHALL BE OTHER THAN FOR GROUNDED, (NEUTRAL), AND GROUNDING CONDUCTORS, CEC 310.110(C).
<br />14. MAXIMUM CONDUCTOR LENGTH BETWEEN SUPPLY SIDE CONNECTION AND OVERCURRENT PROTECTION IS 10 FEET, CEC
<br />705.31.
<br />15. CONNECTIONS ON THE LOAD SIDE OF THE SERVICE DISCONNECTING MEANS OF THE OTHER SOURCE(S) AT ANY
<br />DISTRIBUTION EQUIPMENT ON THE PREMISES SHALL MEET THE FOLLOWING, CEC 705.12(B).
<br />16. DC WIRING INSIDE A BUILDING MUST BE IN METALLIC TYPE RACEWAYS, CONDUITS, ENCLOSURES, OR CABLE SHEATHINGS,
<br />CEC 690.31(G).
<br />17. METALLIC TYPE RACEWAYS, CONDUITS, ENCLOSURES, AND CABLE SHEATHS CONTAINING CIRCUITS OVER 250-VOLTS TO
<br />GROUND MUST BE BONDED IN ACCORDANCE WITH CEC 250.97.
<br />18. ALL EXTERIOR CONDUIT, FITTINGS AND BOXES SHALL BE RAIN TIGHT AND APPROVED FOR USE IN WET LOCATIONS, CEC
<br />314.15
<br />19. FLEXIBLE, FINE-STRANDED CABLES SHALL BE TERMINATED ONLY WITH TERMINALS, LUGS, DEVICES OR CONNECTOR THAT
<br />ARE IDENTIFIED AND LISTED FOR SUCH USE, CEC 690.31(H) & 110.14.
<br />20. CONNECTORS SHALL BE OF LATCHING OR LOCKING TYPE. CONNECTORS THAT ARE READILY ACCESSIBLE AND OPERATING
<br />AT OVER 30 VOLTS SHALL REQUIRE TOOL TO OPEN AND MARKED “DO NOT DISCONNECT UNDER LOAD” OR “NOT FOR
<br />CURRENT INTERRUPTING”, CEC 690.33(C) & (E)(2).
<br />21. EQUIPMENT GROUNDING CONDUCTOR FOR PV MODULES SMALLER THAN 6 AWG SHALL BE PROTECTED FROM PHYSICAL
<br />DAMAGE BY A RACEWAY OR CABLE ARMOR, CEC 690.46 & 250.120(C).
<br />22. THE INTERCONNECTION POINT SHALL BE ON THE SUPPLY SIDE OF ALL GROUND-FAULT PROTECTION EQUIPMENT, CEC
<br />705.32.
<br />23. CABLES/WIRES THAT ARE SUBJECT TO PHYSICAL DAMAGE, SUCH AS THOSE NOT LOCATED UNDER THE MODULES, MUST BE
<br />PROTECTED, CEC 300.4.
<br />24. PROPOSED LOCATIONS OF ELECTRICAL SERVICE REPLACEMENTS MUST ALSO BE APPROVED BY THE ELECTRICAL UTILITY
<br />COMPANY.
<br />25. FOR ELECTRICAL SERVICE REPLACEMENTS, BONDING TO THE METAL PIPES OF NATURAL GAS, HOT WATER, AND COLD
<br />WATER MUST BE PROVIDE, CEC 250.104.
<br />26. GROUNDING ROD ELECTRODES SHALL BE MINIMUM 5/8’’ IN DIAMETER AND INSTALLED 8’ MINIMUM IN CONTACT WITH SOIL,
<br />CEC 250.52(A)(5), 250.53(G).
<br />27. MINIMUM 7/8’’ CLEARANCE FROM ROOF TO BOTTOM OF CONDUIT OR USE A TEMPERATURE ADDER OF 33 DEGREES C. CEC
<br />310.15(B)(3)(C)
<br />28. EXISTING PLUMBING VENTS, SKYLIGHTS, EXHAUST OUTLETS, & VENTILATIONS INTAKE AIR OPENINGS SHALL NOT BE COVERED
<br />OR BLOCKED BY THE SOLAR PHOTOVOLTAIC SYSTEM.
<br />29. EXISTING DWV PLUMBING VENT TERMINATIONS THAT ARE HORIZONTALLY LOCATED CLOSER THAN 12" FROM THE PROPOSED
<br />MODULES, MUST BE REROUTED, OR MUST BE EXTENDED A MINIMUM OF 6" ABOVE THE SURFACE OF THE MODULES, CPC
<br />906.1.
<br />30. EXISTING B-VENT TERMINATIONS, FOR FUEL BURNING APPLIANCES, WHERE ADJACENT TO THE PROPOSED MODULES, MUST
<br />BE EXTENDED 12" ABOVE THE MODULES' TOP SURFACE, CMC 802.6.1(1) & CPC 509.6.1(1).
<br />31. THE MARKINGS, "WARNING: PHOTOVOLTAIC POWER SOURCE", FOR DC RACEWAYS AND CABLE ASSEMBLIES MUST BE AT 10'
<br />O.C.; AND BENDS, ABOVE OR BELOW PENETRATIONS OF ROOFS, CEILINGS, WALLS, OR BARRIERS, CEC 690.31(G)(4).
<br />32. PV COMBINER PANELBOARDS MUST HAVE PERMANENT MARKINGS INDICATING THAT THEY ARE DEDICATED FOR PV CIRCUITS
<br />ONLY NO LOADS ARE TO BE CONNECTED.
<br />33. WORKING CLEARANCES TO BE PROVIDED AT NEW AND EXISTING ELECTRICAL EQUIPMENT, CEC 110.26.
<br />34. A LADDER MUST BE PROVIDED FOR INSPECTIONS IN ACCORDANCE WITH CAL-OSHA REGULATIONS, SECURED AND EXTENDING
<br />3' ABOVE THE ROOF.
<br />35. ALL OF THE REQUIRED MARKINGS, SIGNS, AND LABELS MUST BE INSTALLED ON ALL EQUIPMENT PRIOR TO ANY INSPECTIONS.
<br />36. LABELS SHALL BE REFLECTIVE, AND ALL LETTERS SHALL BE CAPITALIZED AND SHALL BE A MINIMUM HEIGHT OF 3/8'' IN
<br />WHITE ON A RED BACKGROUND. CEC 690.31(G)(4)
<br />37. IDENTIFICATION OF POWER SOURCE RAPID SHUTDOWN AND LABELING SHALL BE IN ACCORDANCE WITH CEC 690.56(C).
<br />38. WHEN THE MAIN CIRCUIT BREAKER IS DERATED, A PERMANENT MARKING MUST BE PROVIDED ON THE PANELBOARD TO
<br />INDICATE THAT THE MAIN CIRCUIT BREAKER HAS BEEN DOWNSIZED TO _______ AMPS, DO NOT UPSIZE IT.
<br />39. PANELS AND MODULES NOT TO BE INSTALLED ON ROOF BELOW AN EMERGENCY ESCAPE AND RESCUE OPENING. CRC
<br />R324.6.2.2
<br />40. GROUND-MOUNTED PV SYSTEMS MUST HAVE A CLEAR, BRUSH-FREE AREA OF 10-FEET AND A FIRE SEPARATION DISTANCE OF
<br />5-FEET MINIMUM TO OTHER STRUCTURES AND PROPERTY LINES, CRC R324.7 & R302.1.
<br />41. PLAN CHECK AND PERMIT FOR PV SYSTEM AND ASSOCIATED EQUIPMENT ONLY.
<br />42. ALL PROJECTS SUBJECT TO FIELD VERIFICATION FOR CODE COMPLIANCE.
<br />43. APPROVED SMOKE AND CARBON MONOXIDE ALARMS ARE REQUIRED WITHIN THE DWELLING UNIT AND SHALL BE
<br />FIELD VERIFIED EITHER THROUGH FINAL BUILDING INSPECTION. SMOKE ALARMS ARE REQUIRED TO BE INSTALLED IN
<br />ALL BEDROOMS, OUTSIDE EACH BEDROOM, AND AT LEAST ONE ON EACH FLOOR OF THE HOUSE. CARBON MONOXIDE
<br />ALARMS ARE REQUIRED OUTSIDE EACH BEDROOM AND AT LEAST ONE ON EACH FLOOR OF THE HOUSE. R314.1,
<br />R315.1
<br />44. NOTIFY SERVING UTILITY BEFORE ACTIVATION OF PV SYSTEM.
<br />APPLICABLE CODES
<br />ALL MATERIALS, EQUIPMENT, INSTALLATION AND WORK
<br />SHALL COMPLY WITH THE FOLLOWING APPLICABLE CODES
<br />2019 CA BUILDING CODES (CBC)
<br />2019 CA RESIDENTIAL CODES (CRC)
<br />2019 CA MECHANICAL CODES (CMC)
<br />2019 CA PLUMBING CODES (CPC)
<br />2019 CA FIRE CODES (CFC)
<br />2019 CA ELECTRICAL CODES (CEC)
<br />2019 CA ENERGY CODES (CEnC)
<br />2019 CALIFORNIA GREEN BUILDING STANDARDS CODE
<br />(CALGreen)
<br />SHEET INDEX
<br />A0 PROJECT INFO, VICINITY MAP, PV NOTES
<br />A1 SITE PLAN
<br />A2 MOUNTING ROOF PLAN
<br />E1 SINGLE LINE DIAGRAM
<br />E2 ELECTRICAL CALCULATIONS
<br />E3 REQUIRED SIGNAGE
<br />E4 - E4.1 MODULE DATA SHEET & CERTIFICATION
<br />E5 - E5.1 INVERTER DATA SHEET & CERTIFICATION
<br />E6 OPTIMIZER DATA SHEET
<br />S1 STANCHION DATA SHEET
<br />S2 RACKING DATA SHEET
<br />S3 - S3.3 RACKING ENGINEERING
<br />S4 RACKING GROUNDING
<br />S5 RACKING CERTIFICATION
<br />MAIN SERVICE PANEL INFORMATION
<br />EXISTING: NO UPGRADE: YES
<br />BUS RATING: (N)225A MAIN BREAKER SIZE: (N)200A
<br />PHASE: 1PH MB POSITION: TOP
<br /># OF WIRES: 3 DERATE?: NO
<br />VOLTAGE: 240V DERATE SIZE: N/A
<br />UTILITY FED: OH
<br />METER#: 222013-607211
<br />PROJECT SCOPE
<br />INSTALLATION OF ROOF MOUNT SOLAR PV SYSTEM
<br />NEW UPGRADE 225A MAIN SERVICE PANEL
<br />PV EQUIPMENT QTY MODEL NO AND MANUFACTURER
<br />MODULES:13 Q.PEAK DUO BLK ML-G10 400
<br />HANWHA Q CELL MODULES
<br />OPTIMIZERS:1 3 P401 SOLAREDGE OPTIMIZERS
<br />INVERTER:1 SE5000H-US (240V) >SI1 @
<br />SOLAREDGE HD INVERTER
<br />SYSTEM SIZE:5.200 DC kW RATING
<br />4.781 CEC AC RATING
<br />ARRAY AREA:21 .1 4 SQFT x 1 3 =274.76 SQFT
<br />PROJECT SITE
<br />STRUCTURAL ONLY
<br />www.vincise.com
<br />S T R U C T U R A L E N G I N E E R S
<br />12.13.2022
<br />***The scope of the plans is for the installation of
<br />the solar photovoltaic system only and the
<br />approval is subject to compliance with all
<br />applicable city and state codes and regulations
<br />regarding construction. The approval of the plans
<br />does not constitute any certification of the
<br />accuracy, completeness, or building permit status
<br />of the existing buildings and structures as shown.
<br />***
<br />Bldg permit #101113461
<br />Elect permit #20178423
<br />Issued on 1/25/23
<br />2238 W Harvard St
<br />01/30/23
|