My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2238 W Harvard St - Plan
PBA
>
Building
>
ProjectDox
>
H
>
Harvard St
>
2238 W Harvard St
>
2238 W Harvard St - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/1/2025 12:02:36 PM
Creation date
6/1/2025 12:02:20 PM
Metadata
Fields
Template:
Plan
Permit Number
20178423
101113461
Full Address
2238 W Harvard St
Document Relationships
101113461 - Permit
(Permit - Plan)
Path:
\Building\Permits\H\Harvard St\2238 W Harvard St
20178423 - Permit
(Permit - Plan)
Path:
\Building\Permits\H\Harvard St\2238 W Harvard St
Text box
ID:
1
Creator:
Import Agent
Created:
6/1/2025 12:02 PM
Modified:
5/30/2025 3:23 PM
Text:
WWW.TITANSOLARPOWER.COM
ID:
2
Creator:
Import Agent
Created:
6/1/2025 12:02 PM
Modified:
5/30/2025 3:23 PM
Text:
http://www.vincise.com
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
38
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
278" <br />2.5" <br />MIN <br />MS <br />P <br />D <br />IN <br />V <br />JB <br />13' <br />2 3' <br />1 8" <br />MIN <br />1 8" <br />MIN <br />1 8" <br />MIN <br />3' <br />3' <br />PROJECT NAME <br />SHEET TITLE <br />SHEET NUMBER <br />PROJECT TITLE <br />JOBSITE ADDRESS <br />DIAZ <br />RESIDENCE <br />5.200 DC KW <br />4.781 KW CEC-AC RATING <br />STRING INVERTER SYSTEM <br />2238 <br />WEST HARVARD ST <br />SANTA ANA, <br />CA 92704 <br />CONTRACTOR <br />TITAN SOLAR POWER CA INC <br />525 W BASELINE ROAD <br />MESA, AZ 8521 0 <br />(855) 729-7652 <br />WWW.TITANSOLARPOWER.COM <br />PROJECT ID# TSP146826 <br />DATE DESCRIPTION <br />REVISION <br />DATE <br />DRAWN1 0-31 -22 <br />DESIGN BY: <br />CAD <br />F O R C A L I I N C . <br />SHELLEY V CALUAG <br />FDGIRUFDOL@JPDLO.FRP <br />323-698-4207 <br />SP: Ascend Energy <br />RD <br />A2 <br />MOUNTING <br />PLAN <br />(N) 1 3 - Q.PEAK DUO BLK ML-G1 0 400 <br />HANWHA Q CELL MODULES WITH <br />P401 SOLAREDGE OPTIMIZERS <br />1 STRING OF 13 MODULES <br />MOUNTING PLAN <br />SCALE: 3/32" = 1 ' <br />SOLAR PANEL DEAD WEIGHT CALCULATION <br />MODULE HANWHA Q CELLS <br />WIDTH (IN) LENGTH (IN) AREA (SQFT) WEIGHT (LBS) QTY <br />TOTAL <br />MODULE <br />AREA <br />TOTAL <br />MODULE <br />WEIGHT <br />41 .1 74.00 21 .1 2 48.50 1 3 274.57 630.50 <br />RACKING EVEREST <br />RACKING <br />WEIGHT <br />LBS/LNFT <br />MOUNTING <br />SYSTEM <br />WEIGHT <br />TOTAL <br />SYSTEM <br />WEIGHT <br />TOTAL <br />ATTACHMENT <br />POINTS <br />POINT <br />LOAD <br />CALCS <br />DISTRIBUTED LOAD <br />CALCULATION <br />.75 78.81 709.31 26 27.28 2.58 PSF <br />NOTE: THE POINT LOADING AND DISTRIBUTED LOADING SHOULD BE MAX 5 LBS/FT2 <br />ROOF COVERAGE <br />TOTAL <br />MODULE <br />AREA <br />ROOF FACE <br />AREA (SQFT) <br />ROOF <br />COVERAGE COMPLIANCE WITH R324.6.2 SET BACK AT RIDGE <br />274.57 4422 6.21 % </= 33%1 8" SET BACK AT <br />RIDGE <br />ROOF INFORMATION <br />ROOF TYPE COMP SHINGLE ROOF - 2 LAYERS <br />RAFTERS AND/OR TRUSS RAFTER SPACING (IN)ATTACHMENT <br />SPACING <br />2 X 4 24" OC 48" OC <br />MODULE <br />SIDE VIEW <br />EVEREST <br />CROSSRAIL 44-X <br />EVEREST SPLICE <br />FOOT X <br />NOTE: <br />MODULES WILL BE INSTALLED <br />FLUSHED TO EXISTING ROOF SLOPE <br />END CLAMP <br />ASSEMBLY <br />EVEREST K2 SOLAR <br />SEAL BUTYL PAD <br />ROOF ATTACHMENT DETAIL <br />COMP SHINGLE <br />SCALE: 2" = 1 '-0" <br />(N) 3/4" EMT CONDUIT <br />RUN ABOVE ROOF OR UNDER EAVES <br />WHERE POSSIBLE <br />WIRING/CONDUIT RACEWAY <br /> WILL BE 7/8'' MINIMUM ABOVE THE <br />ROOFTOP PER CEC 31 0.1 5(B)(3)(C) <br />26 TOTAL ATTACHMENTS <br />@ 4FT ON CENTER <br />M5 X 60 LAG SCREWS <br />5/1 6" <br />2 LAGS PER ATTACHMENT <br />2.5" MIN EMBEDMENT <br />FIRE ACCESS POINT <br />AREA NOT TO BE OVER <br />ANY DOORS, WINDOWS OR <br />OTHER OBSTRUCTIONS. <br />90 AZIMUTH <br />1 8 SLOPE <br />FIRE ACCESS POINT <br />AREA NOT TO BE OVER <br />ANY DOORS, WINDOWS OR <br />OTHER OBSTRUCTIONS. <br />1 <br />8 <br />" <br />M <br />I <br />N <br />F <br />I <br />RE <br />SE <br />TB <br />A <br />C <br />K <br />LEGEND <br />(E) EXISTING <br />(N) NEW <br />(P) PROPOSED <br />CONDUIT RUN <br />VIF VERIFY IN FIELD <br />JUNCTION BOX <br />MAIN SERVICE PANEL <br />AC COMBINER <br />INVERTER <br />AC DISCONNECT <br />SUBPANEL <br />SOLAR METER <br />FIRE ACCESS POINTS <br />FIRE PATHWAY/SETBACKS <br />JB <br />MSP <br />D <br />SP <br />INV <br />AC <br />M <br />x <br />3FT FIRE <br />PATHWAY <br />(N) SE5000H-US (240V) <br />SETAPP SOLAREDGE HD INVERTER <br />(N) UPGRADE 225A MAIN <br />SERVICE PANEL <br />SCE METER: 222013-607211 <br />(N) 30A AC DISCONNECT <br />270 AZIMUTH <br />5 SLOPE <br />270 AZIMUTH <br />1 8 SLOPE <br />3FT FIRE <br />PATHWAY <br />1 <br />8 <br />" <br /> <br />F <br />IR <br />E <br /> S <br />E <br />T <br />B <br />A <br />C <br />K <br />1 <br />8 <br />" <br /> <br />M <br />I <br />N <br /> <br />F <br />I <br />RE <br />SE <br />TB <br />A <br />C <br />K <br />STRUCTURAL ONLY <br />www.vincise.com <br />S T R U C T U R A L E N G I N E E R S <br />12.13.2022 <br />2238 W Harvard St <br />01/30/23
The URL can be used to link to this page
Your browser does not support the video tag.