Laserfiche WebLink
97% <br />0.97 <br />1.21 <br />1.21 <br />25 IQ8PLUS-72-2-US (CEC) <br />FROM JBOX TO IQ COMBINER BOX <br />FROM IQ COMBINER BOX TO FUSED DISCONNECT <br />1 1/2'' <br /> TEMP. DERATE FACTOR (TEMP - 39 + 22 = 61C)0.58 <br /> RACEWAY HEIGHT FROM ROOF <br />PV SYSTEM <br />AS INDICATED <br />SEPTEMBER 13, 2022 <br />JOSHUA CANTOR <br />2327 N SPURGEON ST <br />SANTA ANA, CA 92706 <br />Current Insight, LLC <br />2852 W. Amini Way <br />South Jordan, UT <br />84095 <br />Drafted By: <br />Solar 360 <br />Building Services, Inc <br />Address: <br />1586 N. Batavia St. <br />Orange , CA 92867 <br />Phone Number: <br />888-688-4946 <br />info@solar-360.com <br />License #: 985010-B <br />Drawn By : Narek A. <br />CONTRACTOR <br />3 <br />WIRE SIZE <br />CALCULATIONSFROM PV MODULES TO JBOX1 <br /> #12 AWG Q-CABLE, PV WIRE(2) 1.1 <br />(1) #6 AWG BARE CU EGC <br />2.1 <br />(3) <br />3 <br />(1) <br /> MAXIMUM INVERTER OUTPUT CURRENT <br /> WALL TEMPERATURE FACTOR <br />OUTPUT CALCULATIONS <br />PV SYSTEM MAX DC OUTPUT <br />PV SYSTEM MAX AC OUTPUT <br />1.25 <br />0.91 <br />(2) <br />(1) <br />25 <br /> Pmax (PTC Rating) <br />#10 AWG THWN-2 <br />WIRE CHART WIRE CHART <br />a b c <br />3 BRANCH CIRCUITS <br /> INVERTER OUTPUT MAX CURRENT <br /> COEFFICIENT 1.25 <br />7 <br /> BRANCH CIRCUIT CURRENT a: 7 BREAKER SIZE PER BRANCH CRCT <br />20A <br />0.8ADJST. FACTOR (4 thru 6 WIRES) <br />**1.257 1.21 10.6A <br /> ADJUSTED CONDUCTOR AMPACITY <br />/ / 13.6 0.58 0.8 29.3A <br /> NUMBER OF MICROINVERTERS <br /> 10.00KW <br />9.25KW <br />FROM FUSED DISCONNECT TO MAIN SERVICE PANEL <br /> #6 AWG PV WIRE, 3/4'' LIQUID TIGHT FLEXIBLE NON-METALIC (LFNC) CONDUIT(3) <br />(1) #6 AWG CU EGC SEPARATE EMT CONDUIT <br />4 <br />5 <br />EGC WILL RUN IN A SEPARATE EMT CONDUIT TO GROUND BAR 1/2'' EMT CONDUIT <br />WIRE CHART <br />QTY <br /> CONSIDER CONTINUOUS COEFFICIENT <br /> CONSIDER CONTINUOUS (A)1.25**25 1.21 37.8 <br />*1.25 / 0.91*25 1.21 41.6 <br /> #8 AWG THWN-2 <br /> TEMPERATURE ADJUSTMENT (A) <br />25 <br />Attention!!!!!!! <br />Need Calculation <br />(don't delete this note) <br />25 <br />25 <br />400W <br />* 400 <br />381.5W <br />* 381.5 * <br />REC400AA PURE <br /> #8 AWG CU EGC, <br /> #8 AWG CU EGC, 3/4'' EMT TYPE CONDUIT <br />1'' PVC TYPE CONDUIT <br />Voltage drop: 0.59 <br />Voltage drop percentage: 0.24% <br />Voltage at the end: 239.41 <br />(4) <br />(1) <br />#10 AWG THWN-2 <br /> #8 AWG CU EGC, <br />2.2 <br />FROM PV MODULES TO JBOX2 <br /> #12 AWG Q-CABLE, PV WIRE(4) 1.2 <br />(1) #6 AWG BARE CU EGC <br />9 9 <br /> BRANCH CIRCUIT CURRENT b,c: 9 BREAKER SIZE PER BRANCH CRCT <br />20A**1.259 1.21 13.6A <br />3/4'' EMT TYPE CONDUIT 3/4'' EMT TYPE CONDUIT <br />2327 N Spurgeon <br />St11/17/22