My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2327 N Spurgeon St - Plan
PBA
>
Building
>
ProjectDox
>
S
>
Spurgeon St
>
2327 N Spurgeon St
>
2327 N Spurgeon St - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/1/2025 12:02:32 PM
Creation date
6/1/2025 12:02:21 PM
Metadata
Fields
Template:
Plan
Permit Number
20177977
101112784
Full Address
2327 N Spurgeon St
Stamp
ID:
1
Creator:
Import Agent
Created:
6/1/2025 12:02 PM
Modified:
5/30/2025 3:33 PM
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
18
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
Wyssling Consulting <br />76 N. Meadowbrook Drive <br />Alpine, UT 84004 <br />(201) 874-3483 <br />swyssling@wysslingconsulting.com <br />V = 95 Basic Wind Speed Canor Residence <br />Exposure C ASCE 7-16, Section 26.7 2327 N Spurgeon Street <br />Kz = 0.85 Velocity Pressure Coefficient, ASCE 7-16, Figure 26.10-1 Santa Ana, CA <br />Kzt = 1 Topographic Factor, ASCE 7-16, Section 26.8.2 <br />Kd = 0.85 Directionality Factor, ASCE 7-16, Section 26.6 <br />Ke = 0.996 Ground Elevation Factor, ASCE 7-16, Section 26.9 <br />qh = 16.6 psf qh = 0.00256KzKztKdKeV2 (ASCE 7-16 Eq. 26.10-1) <br />Roof Angle = 5 deg <br />Roof Type Gable <br />sanchor = 64 in Horizontal spacing of roof anchors <br />Atrib = 15.93 sf Panel Area tributary to each roof anchor <br />GCp External Pressure Coefficient, ASCE 7-16, Figure 30.3-2 <br />Roof Zone Zone 1 1' Zone 2 Zone 3 <br />-1.69 -0.90 -2.29 -3.18 <br />ga = 0.77 Pressure Equalization Factor, ASCE 7-16 Figure 29.4.-8 <br />gE = 1.00 Edge Array Factor, ASCE 29.4.3 edges < 0.5*building height, and panel spacing < 4ft. <br />pnet = qhGCpgEga = Design Wind Pressure, ASCE 7-16, Equation 29.4-7 <br />Roof Zone 1 1' Zone 2 Zone 3 <br />-22 psf -12 psf -29 psf -41 psf Min Pressure = -16 psf <br />Use 22 psf Use 16 psf Use 29 psf Use 41 psf ULTIMATE <br />x 0.6 = 16 psf 16 psf 18 psf 25 psf ALLOWABLE <br />Connection to Existing Roof Framing <br />F.S. = 1 Additional Factor of Safety applied to withdrawl force, if desired <br />Atrib = 15.9 ft2 <br />DLpanel = 3 psf <br />Roof Zone 1 1'Zone 2 Zone 3 <br />Wuplift = 22 psf 16 psf 29 psf 41 psf <br />Plag = F.S. x Atrib x (0.6D - 0.6W) = Withdrawl force for each roof anchor <br />Roof Zone 1 1' Zone 2 Zone 3 <br />-183.5 lbs -128.5 lbs -257.0 lbs -366.3 lbs <br />Connection Capacity <br />db = 5/16 in Lag Screw diameter <br />Dpen = 2 1/2 in Lag Screw penetration into existing framing member <br />No. of Screws 1 Screws per Connection <br />Species of wood framing <br />CD = 1.6 Load Duration Factor for Wind Loading, NDS Table 2.3.2 <br />Ct = 0.7 Temperature Factor, NDS Table 10.3.4 <br />W = 266 lb/in Withdrawl Capacity, NDS Equation 11.2-1 <br />W' = CD x Ct x W = 298 lb/in Adjusted withdrawl value <br />Pallow = Dpen x W' = 745 lbs <br />Roof Zone 1 1' Zone 2 Zone 3 <br />DEMAND = 184 lbs 128 lbs 257 lbs 366 lbs <br />CAPACITY = 745 lbs 745 lbs 745 lbs 745 lbs <br />up to72in ok up to72in ok up to72in ok up to72in ok <br />Douglas Fir-Larch <br />Wind Uplift <br />Rooftop Solar Panels Parallel to Roof Surface <br />ASCE 7-16, Section 29.4.4 <br />This analysis calculates the <br />capacity of the lag screws <br />only. For capacity of the <br />complete mounting system, <br />please see manufacturer's <br />recommendations. <br />2327 N Spurgeon <br />St11/17/22
The URL can be used to link to this page
Your browser does not support the video tag.