Laserfiche WebLink
N <br />A <br />B <br />EG <br />C <br />GEC <br />(N)60A 2P <br />(E)200 <br />EXISTING 225/200A <br />MAIN SERVICE PANEL <br />240V 1PH BOTTOM FED <br />BOND TO EXISTING <br />EUFER OR DRIVE A <br />NEW GROUND ROD AS <br />NEEDED <br />A <br />GNDGND <br />C1 B <br />1 BRANCH CIRCUIT OF 9 <br />MICRO INVERTERS <br />A1B1 <br />EGC <br />D <br />AC- <br />AC+ <br />1 BRANCH CIRCUIT OF 10 <br />MICRO INVERTERS <br />A2B2 <br />AC- <br />AC+ <br />D <br />EGC <br />1 BRANCH CIRCUIT OF 10 <br />MICRO INVERTERS <br />A2B2 <br />AC- <br />AC+ <br />D <br />EGC <br />GN <br />D <br />NE <br />U <br />T <br />R <br />A <br />L <br />C <br />C1 (N)20A 2P <br />(N)20A 2P <br />(N)20A 2P <br />15A 2P <br />MONITORING <br />PR <br />O <br />J <br />E <br />C <br />T <br />: <br />DRAWN BY: <br />DATE: <br />SOLAR MAX RENEWABLE <br />ENERGY PROVIDER INC <br />3080 12TH STREET, <br />RIVERSIDE, CA 92507 <br />TEL: (951) 300-0788 <br />FAX: (951) 213-3099 <br />CLASS: C-46 LIC# 972048 <br />CLASS: C-10 LIC# 999740 <br />E6 <br />SHEET NUMBER: <br />APN#: <br />MODULES: <br />INVERTER: <br />AHJ: <br />SYSTEM kW: <br />PR <br />O <br />P <br />O <br />S <br />E <br />D <br /> <br />S <br />Y <br />S <br />T <br />E <br />M <br /> <br />S <br />I <br />Z <br />E <br /> <br />I <br />S <br /> <br /> <br />11 <br />. <br />6 <br />K <br />W <br />SO <br />L <br />A <br />R <br /> <br />P <br />H <br />O <br />T <br />O <br />V <br />O <br />L <br />T <br />A <br />I <br />C <br /> <br />S <br />Y <br />S <br />T <br />E <br />M <br /> <br />F <br />O <br />R <br />: <br />AL <br />E <br />X <br /> <br />W <br />O <br />N <br />G <br /> <br />& <br /> <br />N <br />G <br />A <br />N <br /> <br />D <br />O <br />A <br />N <br />(7 <br />1 <br />4 <br />) <br /> <br />6 <br />8 <br />4 <br />- <br />4 <br />4 <br />8 <br />2 <br /> 2 <br />2 <br />6 <br />2 <br /> <br />N <br /> <br />L <br />Y <br />O <br />N <br /> <br />S <br />T <br />SA <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />5 <br />BUILDING HT: <br />MOUNTING <br />HARDWARE: <br />C.BE <br />1/4/2023 <br />39605622 <br />2 STORY <br />Q.PEAK DUO <br />BLK-ML-G10+ 400 <br />11.6KW <br />QUICK MOUNT <br />IQ8A-72-2-US <br />CITY OF SANTA ANA <br />UTILITY COMPANY: <br />MAIN SERVICE VOLTAGE: <br />MAIN PANEL CONDITION: <br />SERVICE ENTRANCE: <br />MAIN SERVICE PANEL RATING: <br />METER NUMBER: <br />MAIN CIRCUIT BREAKER RATING: <br />SERVICE INFO <br />SCE <br />240V <br />EXISTING <br />225A <br />200A <br />222014-197900 <br />UNDERGROUND <br />MAIN PANEL MANUFACTURER: SQUARE D QTY: <br />WATTAGE: <br />SERVICE VOLTAGE: <br />CEC EFFICIENCY: <br />INVERTER SPECS <br />IQ8A-72-2-US <br />29 <br />349W <br />240V <br />97.5% <br />MAX. OUTPUT I: 1.45A <br />ENPHASE <br />QTY: <br />STC WATTAGE: <br />Isc: <br />Imp: <br />MODULE SPECS <br />PTC WATTAGE: <br />FRAME COLOR: <br />Voc: <br />Vmp: <br />29 <br />400W <br />371.5W <br />BLACK <br />45.3V <br />37.13V <br />11.14A <br />10.77A <br />Q.PEAK DUO BLK-ML-G10+ 400 <br />HANWHA QCELLS AVG.AMBIENT TEMP: <br />RECORD LOW: <br />CONDUIT HEIGHT: <br />PER 310.15 (B)(2)(a) <br />TEMP RATING: <br />AMBIENT TEMPERATURE SPECS <br />ROOF TOP ADDER: <br />ROOF TOP TEMP: <br />I CORRECTION: <br />ƒ& <br />V CORRECTION: <br />ƒ& <br />ƒ& <br />ƒ& <br />ƒ& <br />0.65 <br />1.12 <br />A <br />B <br />C <br />D <br />FREE AIR 2 Q CABLE ƒ&30# 12 1 0.65 19.5 13.05 16.3125 # 6 BARE 20 240 0.41% <br />CONDUIT <br />TYPE <br />WIRE <br />QTY. <br />WIRE <br />SIZE <br />WIRE <br />TYPE <br />TEMP. <br />RATING <br />WIRE <br />AMP <br />CONDUIT <br /> FILL DERATE <br />TEMP. <br />DERATE <br />ADJ. WIRE <br />AMP <br />CIRCUIT <br />AMP <br />CIRCUIT <br />AMPX1.25 <br />GRND <br />SIZE <br />GRND <br />TYPE VOLTAGE WIRE <br />LEN. <br />VOLTAGE <br />DROP <br />FREE AIR 2 Q CABLE ƒ&30# 12 1 0.65 19.5 14.5 18.125 # 6 BARE 20 240 0.46% <br /> 3/4"EMT 2 THWN-2 ƒ&40# 10 0.8 1 13.05 16.3125 # 6 THWN-2 70 240 0.86% <br /> 3/4"EMT 2 THWN-2 ƒ&40# 10 0.8 1 14.5 18.125 # 6 THWN-2 70 240 0.96% <br /> 3/4"EMT 3 THWN-2 ƒ&75# 6 1 0.91 42.05 52.5625 # 6 THWN-2 5 240 0.08% <br />TAG <br />A1 <br />A2 <br />B1 <br />B2 <br />C1 <br />32 <br />32 <br />68.25 <br />120% RULE <br />BUS BAR RATING: 225A <br />MAIN BREAKER: 200A <br />ALLOWABLE BACKFEED:70A <br />PROPOSED BACKFEED: 60A <br />SINGLE LINE NOTES: <br />1. $OOPRGXOHVZLOOEHJURXQGHGLQDFFRUGDQFHZLWKFRGHDQGWKHPDQXIDFWXUHU¶V <br />installation instructions <br />2. All PV equipment shall be listed by a recognized tested lab <br />3. Notify serving utility before activation of PV system <br />4. When a back fed breaker is the method of utility interconnection, breaker shall not <br />read line and load. <br />5. When a back fed breaker is the method of utility interconnection, the breaker shall <br />be installed at the opposite end of the bus bar of the Main Breaker <br />6. Work clearances around electrical equipment will be maintained per NEC <br />110.26(a)(1), 110.26(a)(2) & 110.26(a)(3) <br />7. All exterior conduits, fittings and boxes shall be rain-tight and approved for use in <br />wet locations per NEC 314.15 <br />8. All metallic raceways and equipment shall be bonded and electrically continuous <br />9. All PV equipment, systems and all associated wiring and interconnections shall be <br />installed by Qualified Persons <br />10. The photovoltaic system conductors shall be identified and grouped. The means of <br />identification shall be permitted by separated color coding, marking tape, tagging <br />or other approved means. NEC 690.4(B) <br />11. The photovoltaic system is Rapid Shut Down ready. CEC 690.12 <br />12. Optimizer with built in rapid shutdown located at each module. <br />13. Panel is compliant with NEC 705.12(B)(2)(3)(c) <br />MODULES AND RAILS TO BE ELECTRICALLY <br />BONDED TO GROUND VIA: <br />RAIL INTEGRATED BONDING UL2703 LISTED <br />GROUNDING METHOD <br />2262 N Lyon St - <br />2017948205/30/23