2301 W San Lorenzo Ave - Plan
PBA
>
Building
>
ProjectDox
>
S
>
San Lorenzo Ave
>
2301 W San Lorenzo Ave
>
2301 W San Lorenzo Ave - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/1/2025 12:02:39 PM
Creation date
6/1/2025 12:02:27 PM
Metadata
Fields
Template:
Plan
Permit Number
20179892
101115434
Full Address
2301 W San Lorenzo Ave
Document Relationships
101115434 - Permit
(Permit - Plan)
Path:
\Building\Permits\S\San Lorenzo Ave\2301 W San Lorenzo Ave
20179892 - Permit
(Permit - Plan)
Path:
\Building\Permits\S\San Lorenzo Ave\2301 W San Lorenzo Ave
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
28
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
OK <br />PV Panel W 3.00 psf <br />Area of panel 320.00 ft2 <br />Total Roof W 586.58 lbs <br />% increase=(Wadditional)/Wexisting 1.34% <br />The increase in weight as a result of the solar system is less than 10% of the existing structure and therefore no further <br />seismic analysis is required. <br />Limits of Scope of Work and Liability <br />Existing structure is assumed to have been designed and constructed following appropriate codes at <br />time of erection, and assumed to have appropriate permits. The calculations produced are only for the <br />roof framing supporting the proposed PV installation referenced in the stamped planset and were <br />completed according to generally recognized structural analysis standards and procedures, professional <br />engineering and design experience, opinions and judgements. Existing deficiencies which are unknown <br />or were not observable during time of inspection are not included in this scope of work. All PV modules, <br />racking, and mounting equipment shall be designed and installed per manufacturer's approved <br />installation specifications. The Engineer of Record and Engineerinc assume no responsibility for misuse <br />or improper installation. This analysis is not stamped for water leakage. Framing was determined based <br />on information in provided plans and/or photos, along with engineering judgement. Prior to <br />commencement of work, the contractor shall verify the framing sizes, spacings, and spans noted in the <br />stamped plans, calculations, and cert letter (where applicable) and notify the Engineer of Record of any <br />discrepancies prior to starting construction. Contractor shall also verify that there is no damaged framing <br />that was not addressed in stamped plans, calculations, and cert letter (where applicable) and notify the <br />Engineer of Record of any concerns prior to starting construction. Prior to the commencement of work, <br />the contractor shall verify the existing roof and framing conditions. Notify Engineerinc and the engineer of <br />record of any Discrepancies prior to starting construction. Prior to the commencement of work, the <br />contractor shall inspect framing for any damage such as water damage, cracked framing, etc. and notify <br />the E.O.R. if any issues are found.These plans/calculations are stamped for structural code compliance <br />of the roof framing supporting the proposed PV installation reference only. These plans/calculations are <br />not stamped for water leakage. PV modules, racking, and attachment components must follow <br />manufacturer guidelines and requirements. <br />303 N. Glenoaks Blvd Suite #200 Burbank, CA 91 502 | (747)333-5991 | new@engineerinc.io <br />2301 W San <br />Lorenzo Ave06/26/23