Laserfiche WebLink
© SolarEdge Technologies, Ltd. All rights reserved. SOLAREDGE, the SolarEdge logo, OPTIMIZED BY SOLAREDGE are trademarks or registered trademarks of SolarEdge Technologies, Inc. <br />All other trademarks mentioned herein are trademarks of their respective owners. Date: November 8, 2022 DS-000091-ENG. Subject to change without notice. <br />Power Optimizer <br />For Residential Installations <br />S440 / S500 / S500B <br /> S440 S500 S500B UNIT <br />INPUT <br />Rated Input DC Power(1) 440 500 W <br />Absolute Maximum Input Voltage (Voc) 60 125 Vdc <br />MPPT Operating Range 8 – 60 12.5 – 105 Vdc <br />Maximum Short Circuit Current (Isc) of Connected PV Module 14.5 15 Adc <br />Maximum Efficiency 99.5 % <br />Weighted Efficiency 98.6 % <br />Overvoltage Category II <br />OUTPUT DURING OPERTION <br />Maximum Output Current 15 Adc <br />Maximum Output Voltage 60 80 Vdc <br />OUTPUT DURING STANDBY (POWER OPTIMIZER DISCONNECTED FROM INVERTER OR INVERTER OFF) <br />Safety Output Voltage per Power Optimizer 1 ± 0.1 Vdc <br />STANDARD COMPLIANCE(2) <br />EMC FCC Part 15 Class B, IEC61000-6-2, IEC61000-6-3, CISPR11, EN-55011 <br />Safety IEC62109-1 (class II safety), UL1741 <br />Material UL94 V-0, UV Resistant <br />RoHS Yes <br />Fire Safety VDE-AR-E 2100-712:2018-12 <br />INSTALLATION SPECIFICATIONS <br />Maximum Allowed System Voltage 1000 Vdc <br />Dimensions (W x L x H) 129 x 155 x 30 129 x 155 x 45 mm <br />Weight (including cables) 655 gr <br />Input Connector MC4(3) <br />Input Wire Length 0.1 m <br />Output Connector MC4 <br />Output Wire Length (+) 2.3, (-) 0.10 m <br />Operating Temperature Range(4) -40 to +85 ˚C <br />Protection Rating IP68 <br />Relative Humidity 0 – 100 % <br />(1) Rated power of the module at STC will not exceed the Power Optimizer Rated Input DC Power. Modules with up to +5% power tolerance are allowed. <br />(2) For details about CE compliance, see Declaration of Conformity – CE. <br />(3) For other connector types please contact SolarEdge. <br />(4) For ambient temperatures above +70°C power de-rating is applied. Refer to Power Optimizers Temperature De-Rating Technical Note for details. <br />PV System Design Using a SolarEdge <br />Inverter(5) <br />SolarEdge Home <br />Wave Inverter <br />Single Phase <br />SolarEdge Home <br />Short String Inverter <br />Three Phase <br />Three Phase for <br />230/400V Grid <br />Three Phase for <br />277/480V Grid <br />Minimum String Length <br />(Power Optimizers) <br />S440, S500 8 9 16 18 <br />S500B 6 8 14 <br />Maximum String Length (Power Optimizers )25 20 50 <br />Maximum Continuous Power per String 5700 5625 11250 12750 W <br />Maximum Allowed Connected Power per String <br />(Permitted only when the power difference between strings <br />is less than 2,000W) <br />See(6)See(6)13500 15000 W <br />Parallel Strings of Different Lengths or Orientations Yes <br />(5) It is not allowed to mix S-series and P-series Power Optimizers in new installations. <br />(6) If the inverter’s rated AC power ≤ maximum nominal power per string, then the maximum power per string will be able to reach up to the inverters maximum input DC power. <br />Refer to Application Note: Single String Design Guidelines. <br />* 45mm for S500B <br />2330 N Larchmont <br />Ave05/11/23