My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2369 N Flower St - 20181589- DL - Plan
PBA
>
Building
>
ProjectDox
>
F
>
Flower St
>
2369 N Flower St
>
2369 N Flower St - 20181589- DL - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/31/2025 9:42:59 AM
Creation date
6/1/2025 12:04:02 PM
Metadata
Fields
Template:
Plan
Permit Number
20181589
Full Address
2369 N Flower St
Document Relationships
20181589 - Permit
(Permit - Plan)
Path:
\Building\Permits\F\Flower St\2369 N Flower St
Text box
ID:
1
Creator:
Import Agent
Created:
6/1/2025 12:04 PM
Modified:
5/30/2025 3:39 PM
Text:
Matthew Mitera
Polygon
ID:
1
Creator:
Import Agent
Created:
6/1/2025 12:04 PM
Modified:
5/30/2025 3:39 PM
ID:
2
Creator:
Import Agent
Created:
6/1/2025 12:04 PM
Modified:
5/30/2025 3:39 PM
ID:
3
Creator:
Import Agent
Created:
6/1/2025 12:04 PM
Modified:
5/30/2025 3:39 PM
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
52
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
KWH <br />200A <br />N N <br />J-Box <br />L1 L2 <br />G <br />L1 L2 <br />G <br />L1 L2 <br />G <br />J-Box <br />5*''607/$'4 <br />5+0).'.+0' <br />' <br />PHOTOVOLTAIC <br />SOLAR SYSTEM <br />EXISTING <br />200A Service Panel <br />NOT CENTER FED <br />Proposed: <br />40 PV breaker in Service <br />Backfed Breaker to be secured @ opposite (load) <br />end of bus from Main Breaker <br />"New Copper ground rod or irreversibly crimped to <br />building's GEC" <br />ALL PV SYSTEM COMPONENTS SHALL BE PROTECTED FROM PHYSICAL DAMAGE <br />Metal enclosures that are not physically continuous from equipment to the grounding electrode shall be made electrically <br />continuous by bonding each end of the raceway or enclosure to the grounding electrode conductor <br />*Location of Installation of NEW equipment will be a MIN of 36" <br />away from the Gas Meter <br />**Cables in discontigious groups of panels to be placed in 3/4" EMT <br />29.31A <br />29.31*1.25=36.63A <br />so 40A PV Breaker o.k <br />Wire Sizing Calculations <br />(N) - ENPHASE IQ COMBINER PANEL <br /> (Rapid Shutdown Label) <br />(N) -60A AC Disconnect <br />Visible Blade <br />Lockable in Open <br />Position Rated 60A with <br />Outdoor <br />SQUARE-D <br />(2) Enphase AC Interconnect Cables & <br />(1) #6 AWG Bare Copper EGC (free fom <br />physical damage) in free air (Continuos) <br />(2) #10 AWG THWN-2 Copper & <br />(1) #8 THWN-2 Copper GEC in 3/4" EMT <br />(3) #8 AWG THWN-2 Copper <br />and (1) #8 THWN-2 Copper <br />GEC in 3/4" EMT <br />threnched portion see E1 <br />in 1" SCH80 PVC <br />&RPELQHU3DQHOWR0DLQ6HUYLFH3DQHO$0D[&XUUHQW;&RQWLQXRXV&XUUHQWDPELHQWWHPSFRUUHFWLRP) $VR$:* <br /> THWN-2 w/ Cond. Ampt Rating of 55A o.k <br />EXISTING <br />BUILDING <br />GROUNDING <br />ELECTRODE <br /> UFFER <br />String 1 consists of (7) CANADIAN SOLAR CS3W-395P PV Modules connected to (7) IQ8PLUS-72-2-US <br />MicroInverters (97.6% CEC) The MicroInverters' AC Outputs are connected in Parallel@ 240V Split Phase, <br />(13) Maximum units per branch - PANELS ON HOUSE <br />Ungrounded System: <br />THE DC CIRCUIT MEETS THE REQUIREMENTS. FOR <br />UNGROUNDED PV ARRAYS IN NEC 690.35. <br />EQUIPMENT GROUND IS PROVIDED IN THE ENGAGE <br />CABLE. NO ADDITIONAL GEC OR GROUND IS <br />REQUIRED. GROUND FAULT PRETECTION <br />(GFP) IS INTEGRATED INTO THE MICRO INVERTER <br />ENPHASE MICROINVERTERS FULLY MEET RAPID <br />SHUTDOWN REQUIREMENTS IN THE NEW CODE <br />WITHOUT THE NEED TO INSTALL ANY ADDITIONAL <br />ELECTRICAL EQUIPMENT <br />NEW-MICRO-INVERTER SPECS : <br />INVERTER MANUFACTURER: ENPHASE <br />MODULE MODEL # IQ8PLUS-72-2-US <br />MAX INPUT VOLTAGE: 60V <br />PEAK OUTPUT POWER(AC) : 300W <br />NOMINAL AC VOLTAGE: 240V <br />NOMINAL OUTPUT CURRECT: 1.21A <br />MAX UNITS PER 20A BRANCH: 13 <br />CEC WEIGHTED EFFICIENCY: 97.6% <br />MODULE MANUFACTURER: CANADIAN SOLAR <br />MODULE MODEL# CS3W-395P <br />MAX POWER-POINT CURRENT (Imp): 10.26A <br />MAX POWER-POINT VOLTAGE (Vmp): 38.50V <br />OPEN-CIRCUIT VOLTAGE (Voc): 47.00V <br />SHORT-CIRCUIT CURRENT (Isc): 10.82A <br />MAXIMUM POWER (Pmax): 395W <br />CEC PTC RATING: 365.20W <br />15A <br />PRE-MANUFACTURED <br />BUILT IN BREAKER <br />FOR MONITORING <br />Tag A: <br />Tag B: <br /> B <br />(NOT CENTER FED) <br />ARC FAULT PROTECTION FOR ENPHASE: <br />If existing ufer not found, req'd 5/8" diameter <br />ground rod 8'0" min embedment and req'd 6'-0" <br />apart between 2 groundings" <br />MAX IOUT AC=16A <br />EMBEDDED IQ8X-BAT <br />MICRO-INVERTERS -FOR <br />ON-GRID CONSUMPTION <br />DC:4.345kW AC:3.920W TENCO <br />SOLAR <br />MATTHEW MITERA <br />CONTRACTOR C10 C46 <br />6WULQJ-XQFWLRQ%R[WR6XE3DQHO$0D[&XUUHQW;1(&%DPELHQWWHPSWFRUUHFWLRQ) $VR$:* <br /> THWN-2 w/ Cond. Amp Rating of 40A o.k <br />15A <br />Solar <br />Breaker <br />18340 YORBA LINDA BLVD#107-497 <br />YORBA LINDA,CA, 92886 <br />PH. (714) 637-6226 <br />MATTHEW MITERA <br />CONTRACTOR C10 C46 <br />15A <br />Solar <br />Bearker <br />20A <br />Battery <br />Breaker <br />W/ INTEGRATED ENPHASE MICROINVERTERS AND <br />BATTERY MANAGEMENT UNIT <br />(ONE ENCHARGE 10 HAS THREE ENCHARGE 3 UNITS) <br />WIRELESS COMMUNICATION WITH ENPHASE ENVOY <br />NOTE: UP TO (6) UNITS MAY BE DAISY CHAINED <br />WITHOUT REQUIRING ADDITIONAL AC COMBINER <br />SUBPANEL <br />(N) - 1 ENPHASE ENCHARGE 10T-1P-INT BATTERY <br /> A <br />(2)#6AWG THWN-2 Copper & <br />(1) #8THWN-2 Copper in 3 4"EMT <br />40A <br />DC DISC. <br />SWITCH <br />DC DISC. <br />SWITCH <br />DC DISC. <br />SWITCH <br />10KAIC <br />11/1/2023 <br />2369 NORTH FLOWER ST <br />SANTA ANA,CA,92706 <br />PAUL GULINO <br />APN#00207213 <br />2369 NOTH FLOWER ST <br />SANTA ANA,CA,92706 <br />TEL(310)-383-6221 <br />)7.+01 <br />The grounding for the garage PV <br />panels and equipment must be <br />connected to the garage GEC <br />system. If none exists, it must be <br />installed per CEC 250 Part III. CEC <br />690.47(A) <br /> B A <br />String 1 consists of (4) CANADIAN SOLAR CS3W-395P PV Modules connected to (4) IQ8PLUS-72-2-US <br />MicroInverters (97.6% CEC) The MicroInverters' AC Outputs are connected in Parallel@ 240V Split Phase, <br />(13) Maximum units per branch - PANELS ON GARAGE <br />6WULQJ-XQFWLRQ%R[WR6XE3DQHO$0D[&XUUHQW;1(&%DPELHQWWHPSWFRUUHFWLRQ) $VR$:* <br /> THWN-2 w/ Cond. Amp Rating of 40A o.k <br />(3) #8 AWG THWN-2 Copper <br />and (1) #8 THWN-2 Copper <br />GEC in 3/4" EMT <br />2369 N Flower St - <br />2018158912/18/2023
The URL can be used to link to this page
Your browser does not support the video tag.