My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2332 N Spurgeon St - Plan
PBA
>
Building
>
ProjectDox
>
S
>
Spurgeon St
>
2332 N Spurgeon St
>
2332 N Spurgeon St - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/1/2025 12:04:20 PM
Creation date
6/1/2025 12:04:08 PM
Metadata
Fields
Template:
Plan
Permit Number
20179518
101114929
Full Address
2332 N Spurgeon St
Document Relationships
101114929 - Permit
(Permit - Plan)
Path:
\Building\Permits\S\Spurgeon St\2332 N Spurgeon St
20179518 - Permit
(Permit - Plan)
Path:
\Building\Permits\S\Spurgeon St\2332 N Spurgeon St
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
37
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
DC RACEWAYS <br />JB1-2 - TRANSITION BOX <br />(MODEL NOT SPECIFIED) <br />SW1 - DISCONNECT <br />(EATON DG222URB) <br /> <br />I1 - INVERTER <br />(SOLAR EDGE SE7600H-US000BNW4) <br />CB1 IN METER-MAIN COMBO PANEL <br /> <br />METER-MAIN COMBO PANEL <br /> <br />SEE NOTE NO. 4 (MSP) <br />SOLAR PV SYSTEM EQUIPPED <br />WITH RAPID SHUTDOWN <br />TURN RAPID SHUTDOWN <br />SWITCH TO THE 'OFF' <br />POSITION TO SHUT DOWN <br />PV SYSTEM AND REDUCE <br />SHOCK HAZARD IN THE <br />ARRAY. <br />CEC 690.56(C)(1) AND CFC 1205.4.1 <br />SEE NOTE NO. 5 (DC RACEWAYS) <br />WARNING <br />PHOTOVOLTAIC POWER SOURCE <br />CEC 690.31(D)(2) <br />POINT-OF-INTERCONNECTION OR AT MAIN SERVICE DISCONNECT (MSP) <br />! CAUTION: MULTIPLE SOURCES OF POWER ! <br />POWER TO THIS BUILDING IS ALSO SUPPLIED FROM ROOF-MOUNTED SOLAR ARRAYS WITH SAFETY <br />DISCONNECTS AS SHOWN <br />CEC 690.56(B) AND CEC 705.10 <br />EACH DISCONNECTING MEANS FOR <br />PHOTOVOLTAIC EQUIPMENT (JB1, JB2, SW1, I1, CB1 <br />IN MSP) <br />! WARNING ! <br />ELECTRIC SHOCK HAZARD. TERMINALS ON THE <br />LINE AND LOAD SIDES MAY BE ENERGIZED IN THE <br />OPEN POSITION. <br />CEC 690.13(B) <br />AC DISCONNECT (SW1, CB1 IN MSP) <br />MAXIMUM AC OPERATING CURRENT: 32.0A <br />MAXIMUM AC OPERATING VOLTAGE: 240V <br />CEC 690.54 <br />SEE NOTE NO. 6 (SW1) <br />RAPID SHUTDOWN SWITCH <br />FOR SOLAR PV SYSTEM <br />CEC 690.56(C)(3) AND CFC 1205.4.3 <br />PV SYSTEM DISCONNECT (SW1, CB1 IN MSP) <br />PV SYSTEM DISCONNECT <br />CEC 690.13(B) <br />DC DISCONNECT (I1) <br />DIRECT-CURRENT PV POWER SOURCE <br />MAXIMUM VOLTAGE: 400V <br />MAX CIRCUIT-CURRENT: 37.5A <br />DC-TO-DC CONVERTER RATED CURRENT: 15.0A <br />CEC 690.53 <br />ANY AC ELECTRICAL PANEL THAT IS FED BY BOTH <br />THE UTILITY AND THE PHOTOVOLTAIC SYSTEM <br />(MSP) <br />! CAUTION ! <br />MULTIPLE SOURCES OF POWER <br />CEC 705.10 <br />SOLAR BREAKER (MSP) <br />! WARNING ! <br />POWER SOURCE OUTPUT CONNECTION. DO NOT <br />RELOCATE THIS OVERCURRENT DEVICE. <br />CEC 705.12(B)(3)(2) <br />LABELING NOTES <br />1 ALL PLAQUES AND SIGNAGE REQUIRED BY 2022 CEC AND <br />2022 CFC WILL BE INSTALLED AS REQUIRED. <br />2 <br />LABELS, WARNING(S) AND MARKING SHALL COMPLY <br />WITH ANSI Z535.4, WHICH REQUIRES THAT DANGER, <br />WARNING, AND CAUTION SIGNS USED THE STANDARD <br />HEADER COLORS, HEADER TEXT, AND SAFETY ALERT <br />SYMBOL ON EACH LABEL. THE ANSI STANDARD <br />REQUIRES A HEADING THAT IS AT LEAST 50% TALLER <br />THAN THE BODY TEXT, IN ACCORDANCE WITH CEC <br />110.21(B). <br />3 <br />A PERMANENT PLAQUE OR DIRECTORY SHALL BE <br />INSTALLED PROVIDING THE LOCATION OF THE SERVICE <br />DISCONNECTING MEANS AND THE PHOTOVOLTAIC <br />SYSTEM DISCONNECTING MEANS IF NOT IN THE SAME <br />LOCATION IN ACCORDANCE WITH CEC 690.56(B). <br />4 <br />LABEL(S) WITH MARKING, "TURN RAPID SHUTDOWN <br />SWITCH TO THE 'OFF' POSITION TO SHUT DOWN PV <br />SYSTEM AND REDUCE SHOCK HAZARD IN THE ARRAY," <br />SHALL BE LOCATED WITHIN 3 FT OF SERVICE <br />DISCONNECTING MEANS THE TITLE SHALL UTILIZE <br />CAPITALIZED LETTERS WITH A MINIMUM HEIGHT OF 3/8″ <br />IN BLACK ON A YELLOW BACKGROUND, AND REMAINING <br />TEXT SHALL BE CAPITALIZED WITH A MINIMUM HEIGHT <br />OF 3/16″ IN BLACK ON WHITE BACKGROUND <br />5 <br />LABEL(S) WITH MARKING, "WARNING PHOTOVOLTAIC <br />POWER SOURCE," SHALL BE LOCATED AT EVERY 10 FT <br />OF EACH DC RACEWAY AND WITHIN 1 FT OF EVERY TURN <br />OR BEND AND WITHIN 1 FT ABOVE AND BELOW ALL <br />PENETRATIONS OF ROOF/CEILING ASSEMBLIES, WALLS <br />AND BARRIERS. THE LABEL SHALL HAVE 3/8″ TALL <br />LETTERS AND BE REFLECTIVE WITH WHITE TEXT ON A <br />RED BACKGROUND <br />6 <br />LABEL(S) WITH MARKING, "RAPID SHUTDOWN SWITCH <br />FOR SOLAR PV SYSTEM," SHALL BE LOCATED WITHIN 3 <br />FT OF RAPID SHUTDOWN SWITCH THE LABEL SHALL <br />HAVE 3/8″ TALL LETTERS AND BE REFLECTIVE WITH <br />WHITE TEXT ON A RED BACKGROUND <br />23-06537 <br />GR <br />I <br />D <br />- <br />T <br />I <br />E <br />D <br /> <br />P <br />V <br /> <br />S <br />Y <br />S <br />T <br />E <br />M <br />TE <br />D <br />R <br />O <br /> <br />R <br />E <br />S <br />I <br />D <br />E <br />N <br />C <br />E <br />23 <br />3 <br />2 <br /> <br />N <br /> <br />S <br />P <br />U <br />R <br />G <br />E <br />O <br />N <br /> <br />S <br />T <br />SA <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />6 <br />SAFETY LABELS <br />DOC ID:27CEF0-1 <br />DATE:4/27/23 <br />CREATOR:H.V. <br />REVIEWER: <br />REVISIONS <br />PV-4 <br />INSTALLED BY <br />MCPHERSON ENGINEERING <br />Jurupa Valley, CA 92509 <br />(909)569-2244 <br />ryan@mcpherson.engineering <br />Designed by <br />9240 Limonite Ave <br />CHRIS ROMAN: <br />CURRENT HOME <br /> 7100 W. FLORIDA AVENUE <br />HEMET, CA 92545 <br />CLSB-C46, C-10, B # 1045016 <br />2332 N Spurgeon <br />St05/30/23
The URL can be used to link to this page
Your browser does not support the video tag.