Laserfiche WebLink
Page <br />RE <br />V <br />I <br />S <br />I <br />O <br />N <br />S <br />: <br />5. <br />2 <br />8 <br />0 <br /> <br />k <br />W <br /> <br />( <br />D <br />C <br />) <br /> <br />/ <br /> <br />4 <br />. <br />7 <br />9 <br />6 <br /> <br />k <br />W <br /> <br />( <br />C <br />E <br />C <br />- <br />A <br />C <br />) <br />PH <br />O <br />T <br />O <br />V <br />O <br />L <br />T <br />A <br />I <br />C <br /> <br />S <br />Y <br />S <br />T <br />E <br />M <br /> <br />Pr <br />o <br />j <br />e <br />c <br />t <br /> <br />N <br />a <br />m <br />e <br />MA <br />I <br />, <br /> <br />T <br />H <br />I <br />E <br />N <br /> <br />H <br />U <br />U <br />24 <br />1 <br />0 <br /> <br />L <br />O <br />R <br />I <br /> <br />L <br />N <br /> # <br />2 <br />SA <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />6 <br />AP <br />N <br />: <br /> <br />3 <br />9 <br />9 <br />1 <br />5 <br />2 <br />0 <br />1 <br />DA <br />T <br />E <br />: <br /> <br />08 <br />/ <br />1 <br />7 <br />/ <br />2 <br />0 <br />2 <br />3 <br />DR <br />A <br />W <br />N <br /> <br />B <br />Y <br />: <br /> <br />RD <br /> <br />Co <br />n <br />t <br />r <br />a <br />c <br />t <br />o <br />r <br />s <br /> <br />S <br />i <br />g <br />n <br />a <br />t <br />u <br />r <br />e <br />: <br />SI <br />D <br />E <br /> <br />S <br />O <br />L <br />A <br />R <br /> <br />L <br />L <br />C <br /> <br />64 <br />1 <br />2 <br /> <br />C <br />R <br />E <br />S <br />C <br />E <br />N <br />T <br /> <br />A <br />V <br />E <br /> <br />A <br />P <br />T <br />7 <br />BU <br />E <br />N <br />A <br /> <br />P <br />A <br />R <br />K <br />, <br />C <br />A <br /> <br />9 <br />0 <br />6 <br />2 <br />0 <br />PH <br />O <br />N <br />E <br />: <br /> <br />7 <br />1 <br />4 <br />- <br />9 <br />0 <br />8 <br />- <br />6 <br />6 <br />0 <br />9 <br />LI <br />C <br />E <br />N <br />S <br />E <br />: <br /> <br />- <br />- <br />- <br />- <br /> <br />PL <br />O <br />T <br /> <br />P <br />L <br />A <br />N <br />BUILDING SPECIFICATIONS <br />TYPE:ADU <br />STORIES:1 <br />BUILDING HEIGHT(FT.): 12 <br />BUILDING(SQ.FT):830 <br />ROOF SLOPES(°):20.5 <br />ROOF FRAME MEMBER: 2X4 TRUSS <br />O.C. SPACING(IN.):24 <br />MAX SPAN:24' IN BETWEEN SUPPORTS <br />MIN LAG BOLT <br />EMBEDMENT(IN.):2-1/2 <br />MOUNTING AND STANDOFF <br />SPECIFICATIONS <br />ROOFING MATERIAL:SINGLE LAYER COMP <br />RACKING SYSTEM:SOLARWAREHOUSE <br />STANDOFF DISTANCE(IN.): 48 <br />MOUNTING TYPE: FLUSH MOUNT <br />TILT LEG HEIGHT (IN.): N/A <br />HEIGHT OF PV MODULE <br />ABOVE ROOF SURFACE:3" TO 5" <br />MAX CANTILEVER (IN.): 24 <br />SYSTEM SPECIFICATIONS <br />SIZE(kW):5.280 <br />MODULE:(11) HANWHA Q CELLS Q.PEAK DUO <br />XL-G10.3/BFG 480 <br />INVERTER(S):(11) ENPHASE IQ8PLUS-72-2-US <br />INVERTER TYPE:MICRO-INVERTER <br />STRING SCHEDULE:1 CIRCUIT(S) OF 11 MODULES <br />SYSTEM WEIGHT(LBS): 761.20 <br />ARRAY AREA(SQ.FT):273.77 <br />ARRAY AZIMUTH(°):180 <br />LBS/SQ.FT:2.78 <br />03 OF 11 <br />ROOF MOUNTED NOTES: <br />ADDITIONAL BUILDING DATA <br />TOTAL ARRAY AREA (SQ. FT.):273.77 <br />TOTAL PLAN VIEW ROOF AREA (SQ. FT.):830 <br />OCCUPYING PV PERCENTAGE:32.98% <br />SPRINKLER SYSTEM INSTALLED (IFC 903.3.1.3)NO <br />- SOLAR PHOTOVOLTAIC SYSTEM TO BE INSTALLED <br />ON RESIDENTIAL STRUCTURE (GROUP R3 BUILDINGS). <br />-THIS SYSTEM WILL NOT BE INTERCONNECTED UNTIL APPROVAL FROM <br /> THE LOCAL JURISDICTION AND THE UTILITY IS OBTAINED. <br />-A 36-INCH WIDE PATHWAY SHALL BE PROVIDED TO THE EMERGENCY <br />ESCAPE AND RESCUE OPENING(S). <br />-IF THE EXISTING MAIN SERVICE PANEL DOES NOT HAVE A VERIFIABLE <br /> GROUNDING ELECTRODE, IT IS THE CONTRACTOR'S RESPONSIBILITY <br /> TO INSTALL A SUPPLEMENTAL GROUNDING ELECTRODE. <br />R324.6.1 Pathways <br />R324.6.2 Setback at ridge <br />R324.6.2.1 Alternative setback at ridge <br />Exceptions: <br />1. These requirements shall not apply to structures designed and <br />constructed in accordance with the International Residential Code. <br />2. These requirements shall not apply to roofs with slopes of 2 <br />units vertical in 12 units horizontal or less. <br />ROOF ACCESS POINTS PER <br />2022 CRC, R324 (IFC 1204) <br />MSPA/C <br />D.PVLC <br />JB <br />N <br />S <br />EW <br />Scale: 1" = 10' <br />(For 11x17 Print) <br />COUNTY ELECTRONIC STAMP <br />(N)SUPPORT RAILS (TYP.) <br />(E)ROOF FRAMING CENTERLINE <br />(N) TYP. ATTACHMENT POINT <br />(32)IN TOTAL <br />NEMA 3R JUNCTION BOX <br />EXTERIOR CONDUIT (7/8"+ ABOVE ROOF) <br />(N) ENPHASE AC COMBINER BOX 240VAC, NEMA 3R <br />(N)30A AC DISCONNECT 2P - NON FUSIBLE <br />(E) 200A MAIN SERVICE PANEL 120/240VAC SINGLE PHASE 3FT WIDE FIRE PATHWAY <br />ROOF ACCESS POINT <br />(STREET-SIDE) <br />4' <br />2' <br />3' <br />1'-6" <br />1'-6" <br />3' <br />EXISTING A.D.U.3' <br />2410 W Lori Ln #2 <br />09/05/23