Laserfiche WebLink
GENERAL NOTES PROJECT SCOPE:DRAWING INDEX PERMITTING / PLANNING NOTES: <br />VICINITY MAP ADDRESS MAP: PROJECT TEAM: <br />THIS INSTALLATION CONSISTS OF A NEW ROOF MOUNTED PHOTOVOLTAIC (PV) <br />SYSTEM. THE PV SYSTEM IS STATIC MOUNTED. <br />THIS SYSTEM WILL BE INTERCONNECTED TO AND WILL BE OPERATED IN PARALLEL <br />WITH THE CORRESPONDING ELECTRIC GRID PER THE REQUIREMENTS OF THE <br />NATIONAL ELECTRICAL CODE AND UTILITY INTERCONNECT AGREEMENT <br />CONDITIONS OF APPROVAL: <br />1. ALL CONSTRUCTION SHALL OCCUR BETWEEN THE HOURS OF 7AM & 7PM, EXCEPT <br />FOR THE PURPOSE OF EMERGENCIES. <br />1. THIS PV SYSTEM INSTALLATION IS SUBJECT TO INSPECTION BY THE AUTHORITY HAVING <br />JURISDICTION AND <br />2. THIS PROJECT SHALL CONFORM TO THE FOLLOWING CODE VERSIONS: <br />2022 CALIFORNIA BUILDING CODE (CBC 2022) <br />2022 CALIFORNIA ELECTRIC CODE (CEC 2022) <br />2022 CALIFORNIA FIRE CODE (CFC 2022) <br />2022 CALIFORNIA ENERGY CODE (CEnC 2022) <br />2022 CALIFORNIA GREEN BUILDING STANDARDS CODE (CGBSG 2022) <br />2022 CALIFORNIA PLUMBING CODE (CPC 2022) <br />2022 CALIFORNIA MECHANICAL CODE (CMC 2022) <br />AUTHORITY HAVING JURISDICTION <br />3. ROOFTOP MOUNTED PV SYSTEM MEETS FIRE CLASSIFICATION PER CBC 1509.7 AND <br />1505.9 CLASS "A". PV SYSTEM AND ASSOCIATED RACKING SYSTEM ARE TESTED AND <br />IDENTIFIED WITH FIRE CLASSIFICATION IN ACCORDANCE WITH UL 1703. <br />4. SYSTEM UTILIZES RAPID SHUTDOWN DEVICES WHICH MEET 690.12 MODULE LEVEL <br />RAPID SHUTDOWN REQUIREMENTS. <br />5. ALL ELECTRICAL WORK SHALL BE DESIGNED PER 2022 CALIFORNIA ELECTRICAL CODE <br />6. 110.2 APPROVAL: ALL ELECTRICAL EQUIPMENT SHALL BE LABELED, LISTED, OR <br />CERTIFIED BY A NATIONALLY RECOGNIZED TESTING LABORATORY ACCREDITED <br />BY THE UNITED STATES OCCUPATIONAL SAFETY HEALTH ADMINISTRATION <br />SITE CONTACT: <br />CONTRACTOR: <br />THIS DOCUMENT CONTAINS PROPRIETARY <br />INFORMATION. REPRODUCTION, DISCLOSURE, OR <br />USE WITHOUT SPECIFIC WRITTEN <br />AUTHORIZATION OF CONTRACTOR <br />IS STRICTLY FORBIDDEN. <br />DA <br />T <br />E <br />: <br /> <br />1. ALL MATERIAL AND WORKMANSHIP SHALL CONFORM TO THE 2022 TITLE 24 OF THE <br />CALIFORNIA BUILDING CODE, CMC,CPC. CEC AND ALL APPLICABLE LOCAL CODES, <br />ORDINANCES, AND STATE AMENDMENTS. <br />2. THE CONTRACTOR SHALL CHECK ALL DRAWINGS IMMEDIATELY UPON THEIR RECEIPT <br />AND SHALL VERIFY ALL DIMENSIONS AND SITE CONDITIONS BEFORE STARTING WORK. <br />ALL ARCHITECTS AND ENGINEERS SHALL BE NOTIFIED OF ANY DISCREPANCIES. <br />3. NO STRUCTURAL MEMBER SHALL BE CUT OR NOTCHED UNLESS SPECIFICALLY <br />SHOWN, NOTED, OR APPROVED BY ALL. NOTCH DETAILS, IF PROVIDED ARE FOR <br />GENERAL GUIDANCE ONLY. ALL SHALL BE CONTACTED TO APPROVE LOCATIONS OF <br />PROPOSED NOTCHES. <br />4. CONNECTIONS AND IMPLIED CONSTRUCTION ASSEMBLIES THAT ARE NOT SPECIFICALLY <br />DESCRIBED OR DETAILED SHALL BE CONSTRUCTED USING STANDARD CONSTRUCTION <br />PRACTICES IN COMPLIANCE WITH THE GOVERNING CODES AND ORDINANCES. <br />5. WHEN DETAILS LABELED "TYPICAL” OR "SIMILAR" ARE GIVEN ON DRAWINGS, THE <br />CONTRACTOR SHALL APPLY THE INTENT OF THE DETAIL TO THAT SPECIFIC CONDITION. <br />6. WRITTEN INFORMATION AND DIMENSIONS SHALL HAVE PRECEDENCE OVER GRAPHIC <br />INFORMATION. DO NOT SCALE. <br />7. DRAWINGS AND SPECIFICATIONS FOR THIS WORK HAVE BEEN PREPARED IN <br />ACCORDANCE WITH GENERALLY ACCEPTED STANDARDS OF PRACTICE TO MEET THE <br />MINIMUM REQUIREMENTS DF THE CURRENT EDITION DF THE CBC. ANY DISCREPANCIES <br />ON THE PLANS OR ANY DE\/IATIONS FROM THE PLANS WHICH ARE NECESSITATED BY <br />FIELD CONDITIONS OR ANY CONDITION DIFFERENT FROM THOSE INDICATED ON THE <br />PLANS SHOULD BE BROUGHT TO THE ATTENTION OF THE ENGINEER. ALL WORK IS TO BE <br />COORDINATED SO THAT COOPERATION BETWEEN THE TRADES WHERE REQUIRED IS <br />ACCOMPLISHED. <br />8. CONTRACTOR AND SUBCONTRACTORS ARE RESPONSIBLE FOR THE ORDER AND <br />MEANS DF CONSTRUCTION AND ALL TEMPORARY BRACING AND ERECTION DURING <br />CONSTRUCTION. <br />9. APPROVALS BY BUILDING INSPECTORS SHALL NOT CONSTITUTE AUTHORITY TO <br />DEVIATE FROM THE PLANS AND SPECIFICATIONS <br />1O. ALL WORK SHALL CONFORM TO TITLE 24, CALIFORNIA CODE OF REGULATIONS (CCR) <br />11.GRADING PLANS, DRAINAGE IMPROVEMENTS, ROAD AND ACCESS REQUIREMENTS AND <br />ENVIRONMENTAL HEALTH CONSIDERATIONS SHALL COMPLY WITH ALL LOCAL <br />ORDINANCES. <br />X_____________________________ <br />AERIAL PHOTO: <br />X_________________________ <br />Confidentiality Statement: <br />9/ <br />6 <br />/ <br />2 <br />0 <br />2 <br />3 <br /> <br />3 <br />: <br />3 <br />8 <br />: <br />3 <br />4 <br /> <br />P <br />M <br />NA <br />R <br />S <br />A <br /> <br />L <br />L <br />C <br />24 <br />2 <br />1 <br /> <br />N <br /> <br />G <br />R <br />A <br />N <br />D <br /> <br />A <br />V <br />E <br />, <br /> <br />S <br />A <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />5 <br />NARSA LLC <br />2421 N GRAND AVE, SANTA ANA, CA 92705 <br />NARSA LLC <br />SOLAR ELECTRIC SYSTEM <br />THIS PROJECT ENTAILS THE INSTALLATION OF A PHOTOVOLTAIC SYSTEM AT NARSA LLC THE <br />SYSTEM WILL NOT BE A NET ELECTRICITY EXPORTER TO THE UTILITY GRID. <br />SUNGRID SOLAR <br />18271 W MCDURMOTT <br />UNIT E <br />IRVINE, CA 92614 <br />TEL: 949 229 5977 <br />LIC # B, C10: 1037212 <br />T101 <br />Ti <br />t <br />l <br />e <br /> <br />S <br />h <br />e <br />e <br />t <br />SUNGRID SOLAR <br />B, C10: 1037212 <br />3/31/24 <br />SUNGRID SOLAR <br />SOLAR ELECTRIC SYSTEM PROJECT: 38.8kW DCstc / 34.785kW ACcec <br />SUNGRID SOLAR <br />18271 W MCDURMOTT UNIT E <br />IRVINE, CA 92614 <br />949-309-2453 <br />This drawing is the property of SUNGRID SOLAR. This information is <br />confidential and is to be used only in connection with work described <br />by SUNGRID SOLAR. No part is to be discolosed to others without <br />written permission from SUNGRID SOLAR <br />SUNGRID SOLAR <br />LIC # B, C10: 1037212 <br />EXP: 3/31/24Sheet #Sheet Name <br />T101 Title Sheet <br />T102 Notes <br />A100 Site Plan <br />A101 Array Layout <br />E101 Electrical Layout <br />E201 Interconnection SLD <br />E301 Signage <br />SP101 Spec Sheets <br />SP102 Spec Sheets <br />ELECTRICAL: <br />AXIS SOLAR DESIGN <br />27281 LAS RAMBLAS, SUITE 200 <br />MISSION VIEJO, CA 92691 <br />TEL: 323-484-2947 <br />CHAD BUCCINE <br />LICENSE# E20115 <br />No <br />. <br /> <br />De <br />sc <br />ri <br />pt <br />ion <br /> <br />Da <br />t <br />e <br />1 <br />AH <br />J <br /> <br />C <br />O <br />R <br />R <br />E <br />C <br />T <br />I <br />O <br />N <br /> <br />9/ <br />0 <br />7 <br />/ <br />2 <br />3 <br />PROJECT LOCATION DETAILS <br />NARSA LLC <br />2421 N GRAND AVE <br />SANTA ANA, CA 92705 <br />BUILDING INFO: <br />APN: 396-361-06 <br />METER #259000-043781 <br />OCCUPANCY: A-3 <br />CONSTRUCTION TYPE: V-N <br />ONE STORY <br />PROJECT TOTAL: <br />SYSTEM SIZE: <br />38.8 kW STC DC <br />34.785 kW CEC AC <br />PANEL SPECS: <br />(97) UNITED RENEWABLE ENERGY CO., LTD., FBM400MFG-BB MODULES <br />INVERTER SPECS: <br />(2) SOLAREDGE TECHNOLOGIES LTD., SE17.3KUS [208V] <br />OPTIMIZER / RAPID SHUTDOWN SPECS: <br />(49) SOLAREDGE TECHNOLOGIES, P1101 <br />1 <br />Exp. 3-31-19 <br />No. C58724 <br />NITRA MW.DYO <br />REGISTEREDPROFESSIONALENGINEER <br />C <br />V <br />L <br />FOETATS <br />ALIFORNIAICIL <br />-25 <br />www. Loyd W Martin .com <br />Solar Structures Engineering <br />#2023-3630 Structural Only <br />September 7, 2023 <br />Bldg# 101115981 <br />Elec# 20180415 <br /> <br />APPROVALS: <br />PLNG - HJacinto <br />BLDG - JLo <br />ELEC - MSmith <br />2421 N Grand Ave - 101115981 & <br />20180415 <br />3/4/2024