My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2421 N Grand Ave - 101115981 & 20180415 - Plan
PBA
>
Building
>
ProjectDox
>
G
>
Grand Ave
>
2421 N Grand Ave
>
2421 N Grand Ave - 101115981 & 20180415 - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/31/2025 9:43:44 AM
Creation date
6/1/2025 12:04:10 PM
Metadata
Fields
Template:
Plan
Permit Number
20180415
101115981
Full Address
2421 N Grand Ave
Document Relationships
101115981 - Permit
(Permit - Plan)
Path:
\Building\Permits\G\Grand Ave\2421 N Grand Ave
20180415 - Permit
(Permit - Plan)
Path:
\Building\Permits\G\Grand Ave\2421 N Grand Ave
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
18
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
CAUTION <br />POWER TO THIS BUILDING IS ALSO SUPPLIED FROM THE FOLLOWING SOURCES <br />WITH DISCONNECT(S) LOCATED AS SHOWN. DANGEROUS VOLTAGE MAY BE <br />PRESENT AT ALL TIMES. <br />"WARNING" <br />PHOTOVOLTAIC ARRAY <br />DISCONNECTION OF NEUTRAL OR GROUNDED CONDUCTORS MAY RESULT IN <br />OVERVOLTAGE ON ARRAY OR INVERTER <br />6"X8" TYP -CEC 705.10 <br />12 <br />NOTES <br />1. ARTICLES 690 AND 705 MARKINGS SHOWN HEREON <br />2. ALL MARKINGS SHALL CONSIST OF THE FOLLOWING: <br /> A. UV RESISTANT SIGN MATERIAL WITH ENGRAVED OR MACHINE PRINTED <br />LETTERS OR ELECTRO-PLATING <br /> B. RED BACKGROUND COLOR WITH WHITE TEXT AND LINE WORK UON <br /> C. ARIAL FONT <br />3. ALL SIGNS SHALL BE SIZED APPROPRIATELY AND PLACED IN THE <br />LOCATIONS SPECIFIED. <br />4. SIGNS SHALL BE ATTACHED TO THE SERVICE EQUIPMENT USING <br />PERMANENT ADHESIVE, POP-RIVETS, OR SCREWS <br />M <br />JBOX OR <br />COMBINER <br />600V <br />INVERTER <br />WARNING <br />ELECTRICAL SHOCK HAZARD <br />TERMINALS ON THE LINE AND <br />LOAD SIDES MAY BE ENERGIZED <br />IN THE OPEN POSITION <br />! <br />ORANGE WARNING AREA, 690.13(B) <br />WARNING <br />TURN OFF PHOTOVOLTAIC AC <br />DISCONNECT PRIOR TO <br />WORKING INSIDE PANEL <br />! <br />ORANGE WARNING AREA, 110.27(C) <br />WARNING <br />ELECTRICAL SHOCK HAZARD <br />TERMINALS ON THE LINE AND <br />LOAD SIDES MAY BE ENERGIZED <br />IN THE OPEN POSITION <br />! <br />ORANGE WARNING AREA, 690.13(B) <br />DC VOLTAGE IS ALWAYS <br />PRESENT WHEN SOLAR <br />MODULES ARE EXPOSED TO <br />SUNLIGHT <br />PHOTOVOLTAIC <br />690.13(B) <br />DC DISCONNECT <br />MAXIMUM VOLTAGE <br />MAXIMUM CIRCUIT <br />CURRENT <br />MAX RATED OUTPUT <br />CURRENT OF THE CHARGE <br />CONTROLLER OR DC-TO-DC <br />CONVERTER (IF INSTALLED) <br />690.53 <br />WARNING: PHOTOVOLTAIC <br />POWER SOURCE <br />REFLECTIVE STICKER, 690.31(G)(3)(4) <br />WARNING! <br />DUAL POWER SOURCE <br />SECOND SOURCE IS <br />PHOTOVOLTAIC SYSTEM <br />ORANGE WARNING AREA, 705.12(B)(3) <br />PHOTOVOLTAIC <br />AC DISCONNECT <br />690.13(B), 690.54 <br />RATED AC OUTPUT <br />CURRENT <br />NOMINAL OPERATING <br />AC VOLTAGE <br />SOLAR PV SYSTEM EQUIPPED <br />WITH RAPID SHUTDOWN <br />TURN RAPID SHUTDOWN <br />SWITCH TO THE "OFF" <br />POSITION TO SHUTDOWN PV <br />SYSTEM AND REDUCE SHOCK <br />HAZARD IN THE ARRAY <br />The title “SOLAR PV SYSTEM IS EQUIPPED WITH <br />RAPID SHUTDOWN” shall utilize capitalized characters with <br />a minimum height of 9.5 mm (3⁄8 in.) in black on yellow background <br />and the remaining characters shall be capitalized with <br />a minimum height of 4.8 mm (3⁄16 in.) in black on white background. <br />690.56(C)(1)(a) <br />PV <br />ARRAY <br />DC <br />DISCONNECT <br />1 <br />2 <br />3 <br />4 <br />5 <br />6 <br />7 <br />8 <br />10 <br />1 <br />6 <br />34 <br />2 <br />10 <br />12 <br />7 <br />18A <br />18A <br />5 <br />208V <br />96.5A <br />2 <br />6 <br />PV SUB PANEL <br />11 <br />690.56(C)(3) <br />RAPID SHUTDOWN SWITCH <br />FOR SOLAR PV SYSTEM <br />AC <br />DISCONNECT82111 <br />1 <br />721 <br />WARNING! <br />POWER SOURCE OUTPUT <br />CONNECTION. DO NOT <br />RELOCATE THIS OVERCURRENT <br />DEVICE. <br />ORANGE WARNING AREA, 705.12(B)(2)(3)(b) <br />9 <br />9 <br />(E) MAIN SERVICE <br />PANEL <br />(N) PV DISCONNECT FOR <br />UTLITY OPERATION <br />PV ARRAYS <br />To scale on 24x36 paper <br />X_________________________ <br />Confidentiality Statement: <br />6/13/2023 2:24:16 PM <br />Signage <br />NA <br />R <br />S <br />A <br /> <br />L <br />L <br />C <br />24 <br />2 <br />1 <br /> <br />N <br /> <br />G <br />R <br />A <br />N <br />D <br /> <br />A <br />V <br />E <br />, <br /> <br />S <br />A <br />N <br />T <br />A <br />AN <br />A <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />5 <br />E301 <br />SUNGRID SOLAR <br />18271 W MCDURMOTT <br />UNIT E <br />IRVINE, CA 92614 <br />949-309-2453 <br />This drawing is the property of SUNGRID SOLAR. This information is <br />confidential and is to be used only in connection with work described <br />by SUNGRID SOLAR. No part is to be discolosed to others without <br />written permission from SUNGRID SOLAR <br />SUNGRID SOLAR <br />LIC # B, C10: 1037212 <br />EXP: 3/31/24 <br />SUNGRID SOLAR <br />12" = 1'-0"1 Signage - Central <br />No. <br />Descrip <br />tion <br />Date <br />2421 N Grand Ave - 101115981 & <br />20180415 <br />3/4/2024
The URL can be used to link to this page
Your browser does not support the video tag.