BETTER EARTH ELECTRIC INC. <br />16720 MARQUARDT AVE CERRITOS <br />CERRITOS, CA 90703 <br />PHONE #: (888) 373-9379 <br />LIC #: C10-1024460 <br />Nathan Draeger <br />DESIGNER: <br />DESIGN MGR: <br />Paul Kelvin Macavinta <br />NEW PV SYSTEM: 10,800 DC / 7600 AC <br />James Thomas <br />2336 N Riverside Dr, Santa Ana, CA 92706 <br />APN: 00213309 <br />5/2/2023 <br />DATE:TIME: <br />12:47 AM <br />REVISION:DATE:DESCRIPTION: <br />DRAWING TITLE: <br />DRAWING PAGE: <br />SCALE: <br />NOTES SHEET <br />P2 <br />1. RESIDENTIAL ROOF MOUNTED PHOTOVOLTAIC <br />SYSTEM SHALL BE INSTALLED IN ACCORDANCE WITH <br />THE MANUFACTURES SPECIFICATIONS AND THE 2022 <br />CALIFORNIA RESIDENTIAL CODE, SECTIONS R314, R909 <br />AND R918, 2022 CALIFORNIA ELECTRICAL CODE AND <br />2022 CALIFORNIA FIRE CODE. <br />2. CONTRACTORS SHALL BE PRESENT DURING ALL <br />INSPECTIONS. <br />3. THE ROOF ACCESS POINT REQUIRING A LADDER SHALL <br />NOT BE LOCATED OVER A WINDOW, DOOR OR <br />LOCATED WHERE IT CONFLICTS WITH OVERHEAD <br />OBSTRUCTIONS SUCH AS TREE LIMBS, WIRES OR SIGNS <br />[CRC 324.7.1]. <br />4. A LADDER SHALL BE PROVIDED AND SECURED TO THE <br />STRUCTURE AT THE APPROVED ROOF ACCESS POINT <br />PER NOT "C" ABOVE WITH A CAL OSHA APPROVED <br />DEVICE DURING ALL INSPECTIONS. <br />5. EXISTING PLUMBING VENTS, SKYLIGHTS, EXHAUST <br />OUTLETS, VENTILATION'S INTAKE AIR OPENINGS <br />SHALL NOT BE COVERED BY THE SOLAR <br />PHOTOVOLTAIC SYSTEM. <br />6. ALL EQUIPMENT SHALL BE LISTED AND LABELED BY A <br />RECOGNIZED ELECTRICAL TESTING LABORATORY AND <br />INSTALLED PER THE LISTING REQUIREMENTS AND THE <br />MANUFACTURER'S INSTRUCTIONS. [NEC 690.4(D)] <br />7. ALL OUTDOOR EQUIPMENT SHALL BE NEMA 3R RATED, <br />INCLUDING ALL ROOF MOUNTED TRANSITION BOXES <br />AND SWITCHES. <br />8. CONTACT THE SERVICING UTILITY BEFORE POWERING <br />ON THE PHOTOVOLTAIC SYSTEM <br />9. ALL WORK SHALL COMPLY WITH APPLICABLE, LOCAL, <br />MUNICIPAL CODES, AND TO MANUFACTURERS' <br />LISTINGS AND INSTALLATION INSTRUCTIONS. THE PV <br />SOLAR SYSTEM WILL BE INTERCONNECTED AND <br />OPERATED IN PARALLEL WITH THE UTILITY <br />ELECTRICAL GRID PER THE REQUIREMENTS OF THE <br />UTILITY AND APPLICABLE CODES. THE PV SOLAR <br />SYSTEM IS DESIGNED IN COMPLIANCE WITH CEC 690.12 <br />(RAPID SHUTDOWN). <br />JURISDICTION NOTES ELECTRICAL NOTES <br />CONSTRUCTION NOTES <br />UTILITY NOTES <br />1. ALL EQUIPMENT SHALL BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER'S <br />INSTALLATION INSTRUCTIONS. <br />2. ALL OUTDOOR EQUIPMENT SHALL BE RAIN TIGHT WITH MINIMUM NEMA 3R RATING. <br />3. ALL LOCATIONS ARE APPROXIMATE AND REQUIRE FIELD VERIFICATION. <br />4. THE SOLAR INSTALLATION SHALL NOT OBSTRUCT ANY PLUMBING OR MECHANICAL <br />VENTS. <br />5. A LADDER WILL BE IN PLACE FOR INSPECTIONS IN COMPLIANCE WITH CAL OSHA <br />REGULATIONS. <br />6. MODULE MOUNTING STRUCTURE WILL BE TIED DIRECTLY INTO STRUCTURAL <br />ELEMENTS OF SINGLE FAMILY DWELLING ROOF TRUSSES / RAFTERS OR BEAMS <br />ACCORDING TO MOUNTING STRUCTURE DIRECTIONS. <br />7. ROOF COVERING PENETRATIONS SHALL BE DESIGNED, INSTALLED AND MAINTAINED <br />IN ACCORDANCE WITH BUILDING CODE AND THE APPROVED MANUFACTURER'S <br />INSTRUCTIONS SUCH THAT THE ROOF COVERINGS SHALL SERVE TO PROTECT THE <br />BUILDING STRUCTURE. <br />8. CONDUIT, WIRING SYSTEMS AND RACEWAYS FOR PHOTOVOLTAIC CIRCUITS SHALL BE <br />LOCATED AS CLOSE AS POSSIBLE TO THE RIDGE, HIP, OR VALLEY AS DIRECTLY AS <br />POSSIBLE TO POSSIBLE TO AN OUTSIDE WALL TO REDUCE TRIP HAZARDS AND <br />MAXIMIZE VENTILATION OPPORTUNITIES. <br />9. WE WILL MAINTAIN 6" CLEARANCE FROM ALL VENTS AND OBSTRUCTIONS. <br />10. CONDUIT RUNS TO BE DETERMINED IN FIELD <br />1. PV SOURCE CIRCUIT(S) ARE TO BE <br />SUNLIGHT-RESISTANT PV-WIRE AS <br />PERMITTED BY CEC 690.31(B). <br />2. ALL DIRECT CURRENT CIRCUITS ARE TO BE <br />INSTALLED IN METAL RACEWAY FROM THE <br />POINT OF PENETRATION OF THE SURFACE OF <br />THE BUILDING OR STRUCTURE TO THE MAIN <br />SERVICE PANEL AS MANDATED BY CEC <br />690.31(E). <br />3. WEATHERPROOF J-BOX – NEMA 3R. <br />4. ROOFTOP CONDUIT SHALL BE A MINIMUM <br />OF 1" ABOVE THE ROOF SURFACE. <br />5. ALL WORK SHALL COMPLY WITH THE 2022 <br />CALIFORNIA ELECTRICAL CODE (C.E.C.) AND <br />ALL OTHER LOCAL CODES AS APPROVED BY <br />THE AUTHORITY HAVING JURISDICTION. <br />CODE REFERENCES <br />· 2022 CALIFORNIA BUILDING CODE <br />· 2022 CALIFORNIA RESIDENTIAL CODE <br />· 2022 CALIFORNIA ELECTRICAL CODE <br />· 2022 CALIFORNIA FIRE CODE <br />· 2022 CALIFORNIA MECHANICAL CODE <br />· 2022 CALIFORNIA GREEN CODE <br />· 2022 CALIFORNIA PLUMBING CODE <br />· 2022 CALIFORNIA ENERGY CODE <br />· ANY OTHER LOCAL AND MUNICIPAL CODES <br />GENERAL NOTES JURISDICTION STAMPS: <br />2336 N Riverside <br />Dr05/16/23