POWER TO THIS BUILDING ALSO SUPPLIED <br />FROM THE FOLLOWING SOURCES WITH <br />DISCONNECTS LOCATED AS SHOWN <br />CAUTION <br />SERVICE BY QUALIFIED PERSONNEL ONLY <br />N2336 N RIVERSIDE DR, SANTA ANA, CA 92706 <br />Nathan Draeger <br />DESIGNER: <br />DESIGN MGR: <br />Paul Kelvin Macavinta <br />NEW PV SYSTEM: 10,800 DC / 7600 AC <br />James Thomas <br />2336 N Riverside Dr, Santa Ana, CA 92706 <br />APN: 00213309 <br />5/2/2023 <br />DATE:TIME: <br />12:47 AM <br />REVISION:DATE:DESCRIPTION: <br />DRAWING TITLE: <br />DRAWING PAGE: <br />SCALE: <br />ROOFTOP <br />PV ARRAY <br />UTILITY METER AND <br />MAIN SERVICE PANEL INVERTER <br />YOU ARE <br />HERE <br />PLACARD & <br /> PLACARD MAP <br />P7 <br />LABELING PLAN <br />PROPERTY MAP <br />NOTES: <br />FORMAT <br />1. WHITE LETTERING ON A RED BACKGROUND <br />2. MINIMUM 3/8 INCHES LETTER HEIGHT <br />3. ALL LETTERS SHALL BE CAPITALIZED <br />4. ARIAL OR SIMILAR FONT (NON-BOLD) <br />6"X6" DISCONNECT DIRECTORY PLAQUE <br />INSTALL AT MAIN SERVICE PANEL <br />MATERIAL <br />REFLECTIVE, WEATHER RESISTANT <br />MATERIAL <br />SUITABLE FOR THE ENVIRONMENT <br />(USE UL-969 AS STANDARD FOR <br />WEATHER RATING). <br />DURABLE ADHESIVE MATERIALS <br />JURISDICTION STAMPS: <br />STICKER LOCATED INSIDE <br />PANEL NEXT TO PV BREAKER <br />11 <br />[CEC 690.14(C)(2)] PLACE ON AC DISCONNECT <br />8 <br />9 <br />[CEC 705.12(B)(2)(3)(C)] PLACE THIS LABEL AT P.O.C. <br />TO SERVICE DISTRIBUTION EQUIPMENT <br />LABELING NOTES: <br />1.1 LABELING REQUIREMENTS BASED ON THE <br />NATIONAL ELECTRICAL CODE, <br />INTERNATIONAL FIRE CODE 605.11, OSHA STANDARD <br />1910.145, ANSI Z535. <br />1.2 MATERIAL BASED ON THE REQUIREMENTS OF THE <br />AUTHORITY HAVING JURISDICTION. <br />1.3 LABELS TO BE OF SUFFICIENT DURABILITY TO <br />WITHSTAND THE ENVIRONMENT INVOLVED. <br />1.4 LABELS TO BE A MINIMUM LETTER HEIGHT OF 3/8” <br />AND PERMANENTLY AFFIXED. <br />PHOTOVOLTAIC <br />SOLAR BREAKER <br />PHOTOVOLTAIC <br />AC DISCONNECT <br />WARNING <br />THIS EQUIPMENT FED BY MULTIPLE <br />SOURCES. TOTAL RATING OF ALL <br />OVERCURRRENT DEVICES, EXCLUDING <br />MAIN SUPPLY OVERCURRENT <br />DEVICE, SHALL NOT EXCEED <br />AMPACITY OF BUSBAR <br />TURN RAPID SHUTDOWN <br />SWITCH TO THE <br />"OFF" POSITION TO <br />SHUT DOWN PV SYSTEM <br />AND REDUCE <br />SHOCK HAZARD <br />IN THE ARRAY <br />SOLAR PV SYSTEM EQUIPPED <br />WITH RAPID SHUTDOWN <br />SOLAR ELECTRIC <br />PV PANELS <br />10 <br />FOR PV SYSTEMS THAT SHUT DOWN THE ARRAY AND <br />CONDUCTORS LEAVING THE ARRAY: SIGN TO BE <br />LOCATED ON OR NO MORE THAN 3 FT AWAY FROM <br />SERVICE DISCONNECTING MEANS TO WHICH THE PV <br />SYSTEMS ARE CONNECTED AND SHALL INDICATE THE <br />LOCATION OF ALL IDENTIFIED RAPID SHUTDOWN <br />SWITCHES IF NOT AT THE SAME LOCATION. [CEC <br />690.56(C)(1)(A)] <br />2 <br />3 <br />[CEC 690.53] AT EACH DC DISCONNECT MEANS <br />[CEC 690.5(C)] PLACE THIS LABEL ON ALL <br />DISCONNECTING MEANS WHERE <br />ENERGIZED IN AN OPEN POSITION <br />1 <br />[CEC 690.31(G)3 & 4] PLACE ON JUNCTION BOXES <br />AND CONDUIT EVERY 10' <br />WARNING: PHOTOVOLTAIC <br />POWER SOURCE <br />MAXIMUM VOLTAGE <br />PHOTOVOLTAIC SYSTEM <br />DC DISCONNECT <br />MAX CIRCUIT CURRENT <br />15 AMPS <br />TERMINALS ON BOTH THE LINE AND <br />LOAD SIDES MAY BE ENERGIZED <br />IN THE OPEN POSITION <br />ELECTRIC SHOCK HAZARD <br />WARNING <br />MAX RATED OUTPUT <br />CURRENT OF THE CHARGE <br />CONTROLLER <br />OR DC-DC CONVERTER <br />4 <br />[CEC 690.12(5)] PLACE ON INVERTER <br />PHOTOVOLTAIC SYSTEM <br />EQUIPPED WITH <br />RAPID SHUTDOWN <br />7 <br />6 <br />5 <br />[CEC 690.54] PLACE LABEL AT "INTERACTIVE POINT OF <br />INTERCONNECTION" (AT MAIN SERVICE PANEL AND <br />SUBPANEL IF APPLICABLE) <br />[CEC 690.64(B)(4)] PLACE LABEL ON ALL EQUIPMENT <br />CONTAINING OVERCURRENT DEVICES IN CIRCUITS <br />SUPPLYING POWER TO A BUSBAR OR CONDUCTORS <br />SUPPLIED FROM MULTIPLE SOURCES <br />SOURCES: UTILITY GRID AND <br />PV SOLAR ELECTRIC SYSTEM <br />DUAL POWER SUPPLY <br />WARNING <br />RATED AC OUTPUT CURRENT <br />NOMINAL OPERATING AC VOLTAGE 240 V <br />PHOTOVOLTAIC SYSTEM <br />AC DISCONNECT <br />DO NOT RELOCATE <br />THIS OVERCURRENT <br />DEVICE <br />INVERTER OUTPUT CONNECTION <br />WARNING <br />32A <br />480 VDC <br />32 AMPS <br />CEC 705.12(B)(2)(3)(B) PLACE THIS LABEL AT P.O.C. TO <br />SERVICE DISTRIBUTION EQUIPMENT (I.E. MAIN PANEL <br />AND SUBPANEL IF APPLICABLE) <br />SUB <br />PANEL <br />5 6 JUNCTION <br />BOX <br />METER <br />MAIN SERVICE <br />PANEL1 <br />7 <br />6 8 <br />10 <br />9 <br />INVERTER <br />INTEGRATED <br />DC DISCONNECT <br />4 <br />2 3 <br />1 <br />WHEN <br />APPLICABLE <br />AC <br />DISCONNECT <br />PRODUCTION <br />METER <br />AC <br />DISCONNECT <br />ROOFTOP ARRAY <br />AC LOAD <br />CENTER <br />73 5 8 3 5 83 5 <br />5 <br />11 <br />WHEN <br />APPLICABLE <br />WHEN <br />APPLICABLE <br />WHEN <br />APPLICABLE <br />WHEN <br />APPLICABLE <br />PRODUCTION <br />METER <br />WHEN <br />APPLICABLE <br />BETTER EARTH ELECTRIC INC. <br />16720 MARQUARDT AVE CERRITOS <br />CERRITOS, CA 90703 <br />PHONE #: (888) 373-9379 <br />LIC #: C10-1024460 <br />2336 N Riverside <br />Dr05/16/23