DETAIL A 0.63" (16 mm) <br />0.33" (8.5 mm)0.96" (24.5 mm) <br />42.8" (1088 mm) <br />74.0" (1879 mm) <br />4 × Mounting slots (DETAIL A) <br />Frame <br />41.1" (1045 mm) <br />39.2" (996 mm) <br />1.26" (32 mm) <br />8 × Drainage holes <br />15.6" (395.5 mm) <br />4 × Grounding points ø 0.18" (4.5 mm) <br />Label <br />≥49.2" (1250 mm) <br />≥49.2" (1250 mm) <br />Format 74.0 in × 41.1 in × 1.26 in (including frame) <br />(1879 mm × 1045 mm × 32 mm) <br />Weight 48.5 lbs (22.0 kg) <br />Front Cover 0.13 in (3.2 mm) thermally pre-stressed glass <br />with anti-reflection technology <br />Back Cover Composite film <br />Frame Black anodised aluminium <br />Cell 6 × 22 monocrystalline Q.ANTUM solar half cells <br />Junction box 2.09-3.98 in × 1.26-2.36 in × 0.59-0.71 in <br />(53-101 mm × 32-60 mm × 15-18 mm), IP67, with bypass diodes <br />Cable 4 mm² Solar cable; (+) ≥ 49.2 in (1250 mm), (−) ≥ 49.2 in (1250 mm) <br />Connector Stäubli MC4; IP68 <br />Mechanical Specification <br />Qcells pursues minimizing paper output in consideration of the global environment. <br />Note: Installation instructions must be followed. Contact our technical service for further information on approved installation of this product. <br />Hanwha Q CELLS America Inc. 400 Spectrum Center Drive, Suite 1400, Irvine, CA 92618, USA | TEL +1 949 748 59 96 | EMAIL hqc-inquiry@qcells.com | WEB www.qcells.com <br />Sp <br />e <br />c <br />i <br />fi <br />c <br />a <br />t <br />i <br />o <br />n <br />s <br /> <br />s <br />u <br />b <br />j <br />e <br />c <br />t <br /> <br />t <br />o <br /> <br />t <br />e <br />c <br />h <br />n <br />i <br />c <br />a <br />l <br /> <br />c <br />h <br />a <br />n <br />g <br />e <br />s <br /> <br />© <br />Q <br />c <br />e <br />l <br />l <br />s <br /> <br />Q. <br />P <br />E <br />A <br />K <br />_ <br />D <br />U <br />O <br />_ <br />B <br />L <br />K <br />_ <br />M <br />L <br />- <br />G <br />1 <br />0 <br />+ <br />_ <br />s <br />e <br />r <br />i <br />e <br />s <br />_ <br />3 <br />8 <br />5 <br />- <br />4 <br />1 <br />0 <br />_ <br />2 <br />0 <br />2 <br />3 <br />- <br />0 <br />1 <br />_ <br />R <br />e <br />v <br />0 <br />3 <br />_ <br />N <br />A <br />Properties for System Design <br />Maximum System Voltage VSYS [V]1000 (IEC) / 1000 (UL) PV module classification Class II <br />Maximum Series Fuse Rating [A DC]20 Fire Rating based on ANSI / UL 61730 TYPE 2 <br />Max. Design Load, Push / Pull3 [lbs / ft2] 75 (3600 Pa) / 55 (2660 Pa) Permitted Module Temperature <br />on Continuous Duty <br />−40 °F up to +185 °F <br />(−40 °C up to +85 °C)Max. Test Load, Push / Pull3 [lbs / ft2] 113 (5400 Pa) / 84 (4000 Pa) <br />3 See Installation Manual <br />UL 61730, CE-compliant, <br />Quality Controlled PV - TÜV Rheinland, <br />IEC 61215:2016, IEC 61730:2016, <br />U.S. Patent No. 9,893,215 (solar cells), <br />Qualifications and Certificates <br />200 400 600 800 1000 <br />90 <br />100 <br />80 <br />110 <br />10 25 15 200 05 <br />86 <br />98 <br />95 <br />80 <br />100 <br />85 <br />Electrical Characteristics <br />TEMPERATURE COEFFICIENTS <br />Temperature Coefficient of ISC α [% / K]+0.04 Temperature Coefficient of VOC β [% / K] −0.27 <br />Temperature Coefficient of PMPP γ [% / K]−0.34 Nominal Module Operating Temperature NMOT [°F]109 ± 5.4 <br />(43  ± 3 °C) <br />POWER CLASS 385 390 395 400 405 410 <br />MINIMUM PERFORMANCE AT STANDARD TEST CONDITIONS, STC1 (POWER TOLERANCE +5 W / −0 W) <br />Mi <br />n <br />i <br />m <br />u <br />m <br />Power at MPP1 PMPP [W] 385 390 395 400 405 410 <br />Short Circuit Current1 ISC [A]11.04 11.07 11.10 11.14 11.17 11.20 <br />Open Circuit Voltage1 VOC [V]45.19 45.23 45.27 45.30 45.34 45.37 <br />Current at MPP IMPP [A]10.59 10.65 10.71 10.77 10.83 10.89 <br />Voltage at MPP V MPP [V] 36.36 36.62 36.88 37.13 37.39 37.64 <br />Efficiency1 η [%]≥ 19.6 ≥ 19.9 ≥ 20.1 ≥ 20.4 ≥ 20.6 ≥ 20.9 <br />MINIMUM PERFORMANCE AT NORMAL OPERATING CONDITIONS, NMOT2 <br />Mi <br />n <br />i <br />m <br />u <br />m <br /> <br />Power at MPP P MPP [W] 288.8 292.6 296.3 300.1 303.8 307.6 <br />Short Circuit Current ISC [A]8.90 8.92 8.95 8.97 9.00 9.03 <br />Open Circuit Voltage VOC [V]42.62 42.65 42.69 42.72 42.76 42.79 <br />Current at MPP IMPP [A]8.35 8.41 8.46 8.51 8.57 8.62 <br />Voltage at MPP VMPP [V] 34.59 34.81 35.03 35.25 35.46 35.68 <br />1Measurement tolerances PMPP ± 3 %; ISC; VOC ± 5 % at STC: 1000 W/m2, 25 ± 2 °C, AM 1.5 according to IEC 60904-3 • ²800 W/m2, NMOT, spectrum AM 1.5 <br />RE <br />L <br />A <br />T <br />I <br />V <br />E <br /> <br />E <br />F <br />F <br />C <br />I <br />E <br />N <br />C <br />Y <br /> <br />[ <br />% <br />] <br />Qcells PERFORMANCE WARRANTY PERFORMANCE AT LOW IRRADIANCE <br />At least 98 % of nominal power <br />during first year. Thereafter max. <br />0.5 % degradation per year. At <br />least 93.5 % of nominal power <br />up to 10 years. At least 86 % of <br />nominal power up to 25 years. <br />All data within measurement <br />tolerances. Full warranties in <br />accordance with the warranty <br />terms of the Qcells sales <br />organisation of your respective <br />country. <br />Typical module performance under low irradiance conditions in <br />comparison to STC conditions (25 °C, 1000 W/m2). <br />YEARS IRRADIANCE [W/m²] <br />Qcells <br />Industry standard of p-mono* <br />*Standard terms of guarantee for the 5 PV companies with the <br />highest production capacity in 2021 (February 2021) <br />Certified <br />UL 61730 <br />RE <br />L <br />A <br />T <br />I <br />V <br />E <br /> <br />E <br />F <br />F <br />C <br />I <br />E <br />N <br />C <br />Y <br />CO <br />M <br />P <br />A <br />R <br />E <br />D <br /> <br />T <br />O <br /> <br />N <br />O <br />M <br />I <br />N <br />A <br />L <br /> <br />P <br />O <br />W <br />E <br />R <br /> <br />[ <br />% <br />] <br /> <br />2336 N Riverside <br />Dr05/16/23