Laserfiche WebLink
RI <br />D <br /> <br />2 <br />2 <br />4 <br />2 <br />2 <br /> <br />- <br /> <br />H <br />E <br />A <br />T <br />H <br />E <br />R <br /> <br />R <br />U <br />H <br />L <br />PH <br />O <br />T <br />O <br />V <br />O <br />L <br />T <br />A <br />I <br />C <br /> <br />S <br />Y <br />S <br />T <br />E <br />M <br />24 <br />0 <br />4 <br /> <br />E <br /> <br />B <br />U <br />F <br />F <br />A <br />L <br />O <br /> <br />A <br />V <br />E <br />, <br />SA <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />5 <br />AP <br />N <br /> <br />3 <br />9 <br />6 <br />2 <br />8 <br />2 <br />1 <br />3 <br />5205 AVENIDA ENCINAS STE <br />D, CARLSBAD, CA 92008 <br />LICENSE: # 1063901 <br />LICENSE TYPE: A/B <br />LICENSE: # 1063901 <br />LICENSE TYPE: C-10 <br />GENERAL NOTES: <br />ALL EQUIPMENT SHALL BE LISTED AND LABELED BY A <br />RECOGNIZED ELECTRICAL TESTING LABORATORY AND <br />C.A. TEST LAB. EQUIPMENT INSTALLED SHALL BE PER ITS <br />LISTING REQUIREMENTS AND THE MANUFACTURER'S <br />INSTRUCTIONS. [NEC 110.2, 110.3, <br />690.4(B), 690.12(D)] <br />ALL OUTDOOR EQUIPMENT SHALL BE NEMA 3R RATED, <br />INCLUDING ALL ROOF MOUNTED TRANSITION BOXES AND <br />SWITCHES. · ALL EQUIPMENT SHALL BE PROPERLY <br />GROUNDED AND BONDED IN ACCORDANCE WITH NEC <br />ARTICLE 250. <br />ALL PV CIRCUITS CONNECTED AND EQUIPMENT SHALL BE <br />PROTECTED AGAINST OVERCURRENT. OVERCURRENT <br />DEVICES SHALL BE LISTED FOR USE IN PV SYSTEMS. <br />OVERCURRENT PROTECTIVE DEVICES SHALL NOT BE <br />REQUIRED FOR CIRCUITS WITH SUFFICIENT AMPACITY <br />FOR THE HIGHEST AVAILABLE <br />CURRENT. CIRCUITS CONNECTED TO CURRENT LIMITED <br />SUPPLIES AND ALSO CONNECTED TO SOURCES HAVING <br />HIGHER CURRENT AVAILABILITY SHALL BE PROTECTED AT <br />THE HIGHER CURRENT <br />SOURCE CONNECTION. [NEC 690.9] <br />DISCONNECTING MEANS OF THE PV SYSTEM (INCLUDING <br />RAPID <br />SHUTDOWN INITIATION) SHALL BE LOCATED IN A READILY <br />ACCESSIBLE LOCATION NEAR THE EQUIPMENT. [NEC <br />690.13,690.15] <br />RAPID SHUTDOWN EQUIPMENT TO COMPLY WITH NEC <br />690.12. <br />ENERGY STORAGE SYSTEM TERMINALS LOCATED MORE <br />THAN 5 FEET AWAY OR ON OPPOSITE SIDE OF WALL FROM <br />CONNECTED EQUIPMENT MUST HAVE DISCONNECTING <br />MEANS IN ACCORDANCE WITH NEC 706.7(E) AND LABELED <br />PER 706.7(D). A SECOND <br />DISCONNECTING MEANS LOCATED AT THE CONNECTED <br />EQUIPMENT SHALL BE INSTALLED WHERE THE <br />DISCONNECTING MEANS AT THE ESS END OF THE CIRCUIT <br />IS NOT WITHIN SIGHT. <br />THE UTILITY-INTERACTIVE INVERTERS SHALL <br />AUTOMATICALLY DE-ENERGIZE ITS OUTPUT TO THE <br />CONNECTED ELECTRICAL PRODUCTION AND <br />DISTRIBUTION NETWORK VOLTAGE HAS BEEN <br />RESTORED. [NEC 705.40] <br />ALL CONDUCTORS IN EXPOSED OUTDOOR LOCATIONS <br />SHALL BE LISTED AND IDENTIFIED FOR USE IN DIRECT <br />SUNLIGHT AND FOR THE APPLICATION. [NEC 690.31(C) <br />THROUGH (F), 310.10(D)] <br />INSULATION OF EXPOSED CONDUCTORS UNDER THE <br />MODULES SHALL BE USE-2 OR PV-WIRE TYPE FOR PV <br />SYSTEMS (UL 4703 & 854 LISTED) [NEC 690.31(C)] <br />FINE-STRANDED CABLE CONNECTIONS MUST BE MADE IN <br />LUGS AND TERMINALS TO ENSURE A THOROUGHLY GOOD <br />CONNECTION WITHOUT DAMAGING THE CONDUCTORS. <br />[NEC 110.14(A)] <br />FLEXIBLE, FINE-STRANDED CABLES SHALL BE <br />TERMINATED ONLY WITH TERMINALS, LUGS, DEVICES, OR <br />CONNECTORS THAT ARE IDENTIFIED AND LISTED FOR <br />SUCH USE. [NEC 690.31(H), 110.14] <br />ALL PV CIRCUIT CONDUCTORS SHALL BE MARKED ON <br />EACH END AND GROUPED FOR UNIQUE IDENTIFICATION. <br />[NEC 690.31(B)] · ALL EXTERIOR CONDUIT, FITTINGS, AND <br />BOXES SHALL BE RAIN <br />TIGHT AND APPROVED FOR USE IN WET LOCATIONS. [NEC <br />314.15] <br />ALL GROUNDED, (NEUTRAL), CONDUCTORS' INSULATION <br />SHALL BE SOLID WHITE, GRAY, OR WITH 3-WHITE STRIPES. <br />[NEC 200.6, 200.7, 400.22]; ALL GROUNDING CONDUCTORS <br />SHALL BE OF BARE WIRE WITHOUT COVERING, OR WITH <br />INSULATION OF GREEN OR GREEN WITH YELLOW STRIPES, <br />NEC 250.119 & 400.23. THE COLOR OF UNGROUNDED <br />CONDUCTORS SHALL BE OTHER THAN FOR GROUNDED, <br />(NEUTRAL), AND GROUNDING CONDUCTORS. [NEC <br />310.110(C)] <br />MAXIMUM CONDUCTOR LENGTH BETWEEN SUPPLY SIDE <br />CONNECTION AND OVERCURRENT PROTECTION IS 10FT. <br />[NEC 705.31] <br />CONNECTIONS ON THE LOAD SIDE OF THE SERVICE <br />DISCONNECTING MEANS OF THE OTHER SOURCE(S) AT <br />ANY DISTRIBUTION EQUIPMENT ON THE PREMISES SHALL <br />BE IN ACCORDANCE WITH NEC 705.12(B). <br />DC WIRING INSIDE A BUILDING MUST BE IN METALLIC TYPE <br />RACEWAYS, CONDUITS,ENCLOSURES, OR CABLE <br />SHEATHINGS. [NEC 690.31(G)] · METALLIC TYPE <br />RACEWAYS, CONDUITS, ENCLOSURES, AND CABLE <br />SHEATHS CONTAINING CIRCUITS OVER 250-VOLTS TO <br />GROUND MUST BE BONDED IN ACCORDANCE WITH NEC <br />250.97. <br />CONNECTORS SHALL BE OF LATCHING OR LOCKING TYPE. <br />CONNECTORS THAT ARE READILY ACCESSIBLE AND <br />OPERATING AT OVER 30-VOLTS SHALL REQUIRE A TOOL <br />TO OPEN AND MARKED "DO NOT DISCONNECT UNDER <br />LOAD" OR "NOT FOR CURRENT INTERRUPTING." [NEC <br />690.33(C) & (E)(2)] <br />FOR PV MODULES, EQUIPMENT GROUNDING CONDUCTOR <br />(EGC) SMALLER THAN #6-AWG SHALL BE PROTECTED <br />FROM PHYSICAL DAMAGE BY AN IDENTIFIED RACEWAY OR <br />CABLE ARMOR, UNLESS INSTALLED WITHIN HOLLOW <br />SPACES OF THE FRAMING MEMBERS OF BUILDINGS OR <br />STRUCTURES AND WHERE NOT SUBJECT TO PHYSICAL <br />DAMAGE. [NEC <br />690.46, 250.120(C)] <br />THE INTERCONNECTION POINT SHALL BE ON THE SUPPLY <br />SIDE OF ALL GROUND-FAULT PROTECTION EQUIPMENT. <br />[NEC 705.32] <br />CABLES/WIRES THAT ARE SUBJECT TO PHYSICAL <br />DAMAGE, SUCH AS THOSE NOT LOCATED UNDER THE <br />MODULES, MUST BE PROTECTED. [NEC 300.4] <br />FOR ELECTRICAL SERVICE REPLACEMENTS, BONDING TO <br />THE METAL PIPES OF NATURAL GAS, HOT WATER, AND <br />COLD WATER MUST BE PROVIDED. [NEC 250.104] <br />GROUNDING ROD ELECTRODES SHALL BE INSTALLED 8-FT <br />MINIMUM IN CONTACT WITH SOIL AND MINIMUM 5/8-INCH <br />DIAMETER. [NEC 250.52(A)(5), 250.53(G)] · <br />THE MARKINGS, "WARNING: PHOTOVOLTAIC POWER <br />SOURCE", FOR DC RACEWAYS AND CABLE ASSEMBLIES <br />MUST BE NO MORE THAN 10-FT O.C.; AND IS SEPARATED <br />BY ENCLOSURES, WALLS, PARTITIONS, CEILINGS, FLOORS, <br />OR BENDS ABOVE OR BELOW <br />PENETRATIONS. [NEC 690.31(G)(3)&(4)] <br />WORKING CLEARANCES TO BE PROVIDED AT NEW AND <br />EXISTING ELECTRICAL EQUIPMENT. [NEC 110.26] · POWER <br />PRODUCTION SYSTEMS, AND ALL ASSOCIATED WIRING <br />AND INTERCONNECTIONS OPERATING IN PARALLEL WITH <br />A PRIMARY POWER SOURCE SHALL BE PERFORMED ONLY <br />BY QUALIFIED PERSONS. [NEC 690.4(C), 705.8] <br />LABELS SHALL BE REFLECTIVE, AND ALL LETTERS SHALL <br />BE CAPITALIZED AND SHALL BE A MINIMUM HEIGHT OF 3/8" <br />IN WHITE ON A RED BACKGROUND. [NEC 690.31(G)(4)] <br />IDENTIFICATION OF POWER SOURCE RAPID SHUTDOWN <br />AND LABELING SHALL BE IN ACCORDANCE WITH NEC <br />690.56(C). · SMOKE ALARMS AND CARBON MONOXIDE <br />ALARMS ARE REQUIRED TO BE RETROFITTED ONTO THE <br />EXISTING DWELLING AS PER THE 2019 CRC. THESE SMOKE <br />ALARMS ARE REQUIRED TO BE IN ALL BEDROOMS, <br />OUTSIDE EACH BEDROOM, AND AT LEAST ONE ON EACH <br />FLOOR OF THE HOUSE. CARBON MONOXIDE ALARMS ARE <br />REQUIRED TO BE <br />RETROFITTED OUTSIDE EACH BEDROOM AND AT LEAST <br />ONE ON EACH FLOOR OF THE HOUSE (CRC 314,315) <br />SMOKE ALARMS AND CARBON MONOXIDE ALARMS ARE <br />REQUIRED PER CRC SECTIONS 314 AND 315 TO BE <br />VERIFIED AND INSPECTED BY THE INSPECTOR IN THE <br />FIELD. <br />A LADDER MUST BE PROVIDED FOR INSPECTIONS IN <br />ACCORDANCE WITH Cal-OSHA REGULATIONS, SECURED <br />AND EXTENDING 3-FT ABOVE THE ROOF. <br />ALL OF THE REQUIRED MARKINGS, SIGNS, AND LABELS <br />MUST BE INSTALLED ON ALL EQUIPMENT PRIOR TO ANY <br />INSPECTIONS <br />PHOTOVOLTAIC MODULES AND PANEL SYSTEMS <br />INSTALLED ON OR INTEGRAL WITH BUILDINGS, OR TO BE <br />FREESTANDING (NOT ATTACHED TO BUILDINGS) SHALL BE <br />TESTED, LISTED, AND IDENTIFIED WITH A FIRE <br />CLASSIFICATION (CLASS C MINIMUM) IN ACCORDANCE <br />WITH UL1703. WHERE CLASS A OR B ROOFING IS <br />REQUIRED, THE PV SOLAR SYSTEM (PV PANEL & RACK) <br />SHALL HAVE THE SAME CLASS/TYPE RATING OR BETTER. <br />PERMANENT SIGNAGE TO BE RED WITH WHITE LETTERS <br />OCCUPANCY GROUP: R3 <br />CONSTRUCTION TYPE: V-B <br />ALL WORK DONE IN A NEAT AND WORKMANLIKE MANNER <br />BUILDING <br />AREA 2563 <br />STORIES 2 <br />HEIGHT 20 <br />YEAR BUILT 1963 <br />PV-1 <br />TITLE PAGE <br />SYSTEM INFORMATION <br />SYSTEM SIZE 6400 WATTS DC <br />5920 WATTS AC <br />MODULES 16 Q.PEAK DUO BLK ML-G10+400 <br />INVERTER(S) 16 ENPHASE IQ7PLUS-72-2-US <br />BATTERY N/A N/A <br />SCOPE OF WORK <br />PROVIDE AND INSTALL SOLAR <br />PHOTOVOLTAIC ROOF MOUNT 200 / <br />200 MAIN SERVICE PANEL UPGRADE <br />CODE INFORMATION <br />ALL MATERIALS, EQUIPMENT, INSTALLATION AND WORK <br />PERFORMED SHALL BE IN ACCORDANCE WITH THE <br />FOLLOWING CODES: <br />2019 CBC 2019 IBC <br />2019 CRC 2019 IRC <br />2019 CEC 2019 NEC <br />2019 CMC 2019 IMC <br />2019 CPC 2019 IPC <br />2019 CFC 2019 IFC <br />2019 BUILDING EFFICIENCY STANDARDS <br />SHEET INDEX <br />PV-1 TITLE PAGE <br />PV-2 SITE PLAN <br />PV-2.1 ROOF PLAN <br />PV-3 ATTACHMENT DETAIL <br />PV-4 SINGLE LINE <br />PV-5 LABELS AND WARNING SIGNAGE <br />PV-6 MODULE SPEC SHEET <br />PV-6.1 INVERTER SPEC SHEET <br />PV-6.2 CERTIFICATE OF COMPLIANCE <br />PV-6.3 ENPHASE COMBINER SPEC SHEET <br />PHOTOVOLTAIC SYSTEM FOR <br />NAME:HEATHER RUHL <br />ADDRESS:2404 E BUFFALO AVE <br />A.P.N 39628213 <br />JURISDICTION SANTA ANA <br />Bldg# 101113770 <br />Elec# 20178656 <br />Issued 02/14/23 <br />The scope of the plans is for the installation of the solar photovoltaic <br />system only and the approval is subject to compliance with all <br />applicable city and state codes and regulations regarding construction. <br />The approval of the plans does not constitute any certification of the <br />accuracy, completeness, or building permit status of the existing <br />buildings and structures as shown. <br />2404 E Buffalo Ave <br />02/15/23