Laserfiche WebLink
Project : <br />Project Number: <br />By : <br />Date : <br />Ronnell F Eliot <br />PE <br />30-05-2023 <br />Check for Increase in overall seismic loads <br />Array Area =ft2 <br />Number of Arrays = <br />Total Array Area =ft2 <br />Array Load = psf <br />Number of Existing Arrays = <br />Existing Area =ft2 <br />Total Array Wt. = lb <br />Total Roof Area =ft2 <br />DL of Roof = psf <br />Total Wt. of Roof = lb <br />Increase in Seismic Wt. = < 10% <br />Conservatively the Wt. of the Walls tributary to the roof is not included. Seismic weight increase is less than <br />10% and no seismic retrofit or evaluation of existing lateral system is required per Section 503.4 of 2022 <br />CEBC. <br />20.7 <br />22 <br />455.27 <br />1617.9 <br />3.00 <br />1365.8 <br />0 <br />0.00 <br />14.00 <br />22656 <br />6.0% <br />Page 14 <br />2525 N Santiago St - <br />201811081/3/2024