Laserfiche WebLink
Roof Area 1 - Array 3 <br />AVERAGE PSF 3.02 psf <br />TOTAL NUMBER OF MODULES:53 <br />TOTAL KW:24.12 KW <br />TOTAL AREA:1969 ft <br />TOTAL WEIGHT ON ROOF:5941 lbs <br />RACKING WEIGHT:252 lbs <br />MODULE WEIGHT:2745 lbs <br />MODIFIED DEAD LOAD FACTOR 1.0 <br />BALLAST WEIGHT:2944 lbs <br />TOTAL ATTACHMENT COUNT:0 <br />BOM <br />PART QTY <br />RM BALLAST BAY 10 DEGREE 72 <br />RM MODULE CLIP 227 <br />RM HEX BOLT (MODULE CLIP)227 <br />RM ROOF PAD 144 <br />BALLAST BLOCK 92 <br />2 <br />MINIMUM SEISMIC SEPARATION (UNATTACHED ARRAYS) * <br />ARRAY TO ARRAY:12.0" <br />TO FIXED OBJECT ON ROOF:24.0" <br />TO ROOF EDGE WITH QUALIFYING PARAPET:24.0" <br />TO ROOF EDGE WITHOUT QUALIFYING PARAPET:48.0" <br />MAX ARRAY (SEISMIC) (FOR UNATTACHED ARRAYS) * <br />MAX NUMBER OF NORTH-SOUTH ROWS:18 <br />MAX NUMBER OF EAST-WEST COLUMNS:39 <br />*See ASCE 7-16 Section 13.6.12 for more details <br />2621 S Birch St - <br />101112561-201777 <br />9607/17/23