Laserfiche WebLink
Roof Area 1 - Array 9 <br />AVERAGE PSF 3.03 psf <br />TOTAL NUMBER OF MODULES:45 <br />TOTAL KW:20.48 KW <br />TOTAL AREA:1640 ft <br />TOTAL WEIGHT ON ROOF:4973 lbs <br />RACKING WEIGHT:210 lbs <br />MODULE WEIGHT:2331 lbs <br />MODIFIED DEAD LOAD FACTOR 1.0 <br />BALLAST WEIGHT:2432 lbs <br />TOTAL ATTACHMENT COUNT:0 <br />BOM <br />PART QTY <br />RM BALLAST BAY 10 DEGREE 60 <br />RM MODULE CLIP 200 <br />RM HEX BOLT (MODULE CLIP)200 <br />RM ROOF PAD 120 <br />BALLAST BLOCK 76 <br />2 <br />MINIMUM SEISMIC SEPARATION (UNATTACHED ARRAYS) * <br />ARRAY TO ARRAY:12.0" <br />TO FIXED OBJECT ON ROOF:24.0" <br />TO ROOF EDGE WITH QUALIFYING PARAPET:24.0" <br />TO ROOF EDGE WITHOUT QUALIFYING PARAPET:48.0" <br />MAX ARRAY (SEISMIC) (FOR UNATTACHED ARRAYS) * <br />MAX NUMBER OF NORTH-SOUTH ROWS:18 <br />MAX NUMBER OF EAST-WEST COLUMNS:39 <br />*See ASCE 7-16 Section 13.6.12 for more details <br />2621 S Birch St - <br />101112561-201777 <br />9607/17/23