Laserfiche WebLink
ENGINEERING REPORT <br />* Distributed Dead Load 2.51psf <br />* Average Roof Point Dead Load 24.22 lbs <br />Plan review <br />TOTAL NUMBER OF MODULES 11 <br />TOTAL KW 4.29 KW <br />TOTAL AREA ~231 ft <br />Loads Used for Design <br />BUILDING CODE ASCE 7-16 <br />BASIC WIND SPEED 95.00 mph <br />GROUND SNOW LOAD 0.00 psf <br />SEISMIC (SS)1.462 <br />ELEVATION 55.00 ft <br />WIND EXPOSURE B <br />TOPOGRAPHICAL FACTOR KZT 1.00 <br />RISK CATEGORY II <br />VELOCITY PRESSURE, QZ 12.21 psf <br />2 <br />Inspection <br />PRODUCT NXT UMOUNT <br />MODULE MANUFACTURER JA Solar <br />MODEL 11 - JAM54S31 390/MR <br />MODULE WATTS 390 watts <br />MODULE LENGTH 67.79" <br />MODULE WIDTH 44.64" <br />MODULE THICKNESS 1.18" <br />MODULE WEIGHT 47.39 lbs <br />EXPANSION JOINTS Every 40' <br />RAILS DIRECTION EW <br />BUILDING HEIGHT 20.00 ft <br />SHORTEST BUILDING LENGTH 20.00 ft <br />ROOF TYPE Shingle <br />ATTACHMENT TYPE StrongHold Att Kit Comp <br />RAFTER SPACING 24.00" <br />* TOTAL WEIGHT 581.37 lbs <br />ROW SPACING 0.50" <br />COLUMN SPACING 0.50" <br />MID CLAMP NXT UMOUNT COMBO CLAMP <br />END CLAMP NXT UMOUNT COMBO CLAMP <br />* Calculated based on suggested quantity given on part list. <br />2714 W Carlton Pl <br />04/04/23