Laserfiche WebLink
PHOTOVOLTAIC ROOF MOUNT & ENERGY SYSTEM <br />14 MODULES - SYSTEM SIZE STC (5.530 kW DC / 4.060 kW AC) <br />2817 W BROOK ST, SANTA ANA, CA 92704, USA (33.7359372, -117.9083081) <br />SCOPE OF WORK (5.530 kW DC / 4.060 kW AC) <br />STC DC: (14) 395W = 5.530 kW <br />STC AC: (14) 290W = 4.060 kW <br />STORAGE: (1) 3.84kW 10.1kWh <br />● (14) CANADIAN SOLAR INC. CS3N 395MS-BLK MODULES <br />● (14) ENPHASE ENERGY INC. IQ8PLUS-72-2-US 240V MICROINVERTERS <br />● (1) ENPHASE ENERGY INC. IQ BATTERY 10T FOR USMXCA BATTERIES <br />● (1) ENPHASE IQ SYSTEM CONTROLLER 2 <br />● 2x BRANCHES OF 7 CONNECTED IN PARALLEL <br />x ATTACHMENT - SOLARHOOK FLAT 004AT1H <br />x RAIL: UNIRAC- SOLARMOUNT LIGHT <br />GOVERNING CODES <br />● 2022 CALIFORNIA FIRE CODE <br />● 2022 CALIFORNIA BUILDING CODE <br />● 2022 CALIFORNIA RESIDENTIAL CODE <br />● 2022 CALIFORNIA ELECTRICAL CODE <br /> MAIN PANEL REPLACEMENT: EXISTING 100 AMP MAIN PANEL <br /> WITH 100 AMP MAIN BREAKER TO BE REPLACED WITH NEW <br /> 225 AMP MAIN PANEL WITH NEW 200 AMP MAIN BREAKER. <br />DIG ALERT (811) IS TO BE CONTACTED AND COMPLIANCE WITH <br />EXCAVATION SAFETY IN ACCORDING WITH GOVERNMENT CODE 4216 <br />WILL BE FOLLOWED, PRIOR TO ANY EXCAVATION TAKING PLACE. <br />THE SURGE PROTECTION DEVICE (SPD) SHALL COMPLY WITH 2022 <br />CALIFORNIA <br />ELECTRICAL CODE 230.67 THE SPD MUST BE EITHER TYPE 1 OR TYPE 2. <br />ARRAY LOCATION(S) <br />PROJECT SITE <br />GENERAL NOTES <br />1) ALL PANELS, SWITCHES, ETC. SHALL HAVE SUFFICIENT GUTTER <br />SPACE AND LUGS IN COMPLIANCE WITH UL REQUIREMENTS TO <br />ACCOMMODATE CONDUCTORS SHOWN. <br />2) THIS SYSTEM WILL NOT BE INTERCONNECTED UNTIL APPROVAL <br />FROM THE LOCAL JURISDICTION AND UTILITY IS OBTAINED. <br />3) ALL EXTERIOR ELECTRICAL DEVICES AND EQUIPMENT <br />INCLUDING THOSE THAT ARE EXPOSED TO OUTSIDE <br />ENVIRONMENT SHALL BE WEATHERPROOF AND SHALL BE <br />LISTED BY 'UL' FOR THE TYPE OF APPLICATION AND 'UL' LABEL <br />SHALL APPEAR ON ALL ELECTRICAL EQUIPMENT. <br />4) WIRING METHOD SHALL BE EMT ABOVE GROUND MOUNTED IN <br />CONCEALED SPACES (UNLESS APPROVED OTHERWISE) AND <br />SCHEDULE-40 PVC FOR BELOW GROUND INSTALLATIONS <br />UNLESS NOTED OTHERWISE. <br />5) AN OSHA APPROVED LADDER PROVIDING ACCESS TO ALL <br />PORTIONS OF THE ARRAY SHALL BE SECURED IN PRIOR TO <br />REQUESTING INSPECTION. <br />6) IT IS THE CONTRACTOR'S RESPONSIBILITY TO INSTALL A <br />SUPPLEMENTAL GROUNDING ELECTRODE CONDUCTOR IF <br />NECESSARY. <br />7) OCCUPANCY TYPE: R-3 <br />8) CONSTRUCTION TYPE: VB <br />9) ENPHASE DEVICES ARE WITHIN MANUFACTURER'S REQUIRED <br />GUIDELINE, PV ARRAY DOES NOT EXCEED MAX DISTANCE OF <br />150'. <br />10) ALL ENSEMBLE EQUIPMENT MUST BE WITHIN 50' OF EACH <br />OTHER. <br />11) IF THERE ARE COMMUNICATION ISSUES WITH GATEWAY, UB <br />EXTENDER CAN BE USED TO RELOCATE COMMS KIT NEAR IQ <br />SYSTEM CONTROLLER & BATTERY. <br />12) IQ BATTERY UNITS SHOULD NOT BE INSTALLED IN DIRECT <br />SUNLIGHT. <br />REV <br />SHEET NAME <br />SHEET SIZE <br />SHEET NUMBER <br />ANSI B <br />DATE DESCRIPTION <br />REVISIONS <br />PV-1 <br />HOMEOWNER INFO <br />11" X 17" <br />SIGNATURE & SEAL <br />COVER PAGE <br />CONTRACTOR: COMPLETE SOLARIA <br />ADDRESS: 3000 EXECUTIVE PKWY, SUITE <br />504, SAN RAMON, CA 94583 <br />PHONE: 8772994943 <br />LICENSE #: 961988 <br />JO <br />S <br />E <br /> <br />G <br />O <br />M <br />E <br />Z <br />28 <br />1 <br />7 <br /> <br />W <br /> <br />B <br />R <br />O <br />O <br />K <br /> <br />S <br />T <br />, <br />SA <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />4 <br />, <br /> <br />U <br />S <br />A <br />AP <br />N <br />: <br /> <br />1 <br />0 <br />9 <br />- <br />7 <br />4 <br />1 <br />- <br />1 <br />6 <br /> <br /> <br /> <br />PH <br />O <br />N <br />E <br />: <br /> <br />7 <br />1 <br />4 <br />3 <br />2 <br />1 <br />3 <br />5 <br />5 <br />4 <br />EM <br />A <br />I <br />L <br />: <br /> <br />j <br />o <br />s <br />e <br />g <br />o <br />m <br />e <br />z <br />1 <br />0 <br />1 <br />7 <br />5 <br />7 <br />@ <br />g <br />m <br />a <br />i <br />l <br />. <br />c <br />o <br />m <br />COVER PAGE <br />HOUSE PHOTO <br />SCALE: NTS <br />VICINITY MAP <br />SCALE: NTS <br />SHEET INDEX <br />PV-1 COVER PAGE <br />PV-2 SITE PLAN <br />PV-3 ATTACHMENT SHEET <br />PV-3.1 ATTACHMENT DETAIL <br />PV-3.2 STRING PLAN WITH MODULES <br />PV-4 THREE LINE DIAGRAM <br />PV-4.1 EQUIPMENT ELEVATION <br />PV-4.2 LOAD CALCULATION <br />PV-4.3 PANEL SCHEDULES <br />PV-5 WIRING CALCULATION <br />PV-6 PLACARDS <br />PV-7+ EQUIPMENT SPECIFICATION <br />AHJ: SANTA ANA (CITY OF), CALIFORNIA <br />UTILITY: SOUTHERN CALIFORNIA EDISON CO <br />LE <br />G <br />E <br />N <br />D <br />NEW PV MODULE <br />FIRE SETBACK <br />OPTIMIZER <br />MICRO-INVERTER <br />ROOF ATTACHMENT <br />ROOF ACCESS POINT <br />DIMENSIONS <br />PROPERTY LINE <br />RAFTER/TRUSS <br />RAIL <br />FENCE <br />GATE <br />MSP MAIN SERVICE PANEL <br />(NEW, 225A) <br />UM UTILITY METER <br />(NEW) <br />PM PRODUCTION METER <br />(N/A) <br />BAT BATTERY <br />(NEW) <br />INV (0) INVERTER <br />(N/A) <br />LC LOAD CENTER (COMBINER <br />PANEL) (NEW) <br />SM SOLAREDGE METER <br />(N/A) <br />BLP BACKUP LOAD PANEL <br />(N/A) <br />AC AC DISCONNECT UNFUSED <br />(NEW) <br />ACF AC DISCONNECT FUSED <br />(N/A) <br />JB JUNCTION BOX <br />(NEW) <br />AT AUTO TRANSFORMER <br />(N/A) <br />SUB SUB PANEL <br />(NEW) <br />DCD DC DISCONNECT <br />(N/A) <br />DCC DC COMBINER <br />(N/A) <br />EE EXISTING EQUIPMENT <br />STRING <br />IQ IQ SYSTEM CONTROLLER 2 <br />(NEW)RSD RAPID SHUTDOWN DEVICE <br />(NEW) <br />CONDUIT <br />CEC AC RATING: 5.012 <br />Q <br />DIRECT <br />Signed 12/14/2023 <br />Bldg# 101118483 <br />Elec# 20182269 <br />Approvals: <br />Elec - MSmith <br />The scope of the plans is for the installation of <br />the solar photovoltaic system only and the <br />approval is subject to compliance with all <br />applicable city and state codes and regulations <br />regarding construction. The approval of the <br />plans does not constitute any certification of the <br />accuracy, completeness, or building permit <br />status of the existing buildings and structures as <br />shown. <br />2817 W Brook St - <br />201822693/19/2024