Laserfiche WebLink
SYSTEM SUMMARY STC (5.530 kW DC / 4.060 kW AC) <br />STC DC: (14) 395W = 5.530 kW <br />STC AC: (14) 290W = 4.060 kW <br />STORAGE: (1) 3.84kW 10.1kWh <br />● (14) CANADIAN SOLAR INC. CS3N 395MS-BLK MODULES <br />● (14) ENPHASE ENERGY INC. IQ8PLUS-72-2-US 240V MICROINVERTERS <br />● (1) ENPHASE ENERGY INC. IQ BATTERY 10T FOR USMXCA BATTERIES <br />● (1) ENPHASE IQ SYSTEM CONTROLLER 2 <br />● 2x BRANCHES OF 7 CONNECTED IN PARALLEL <br />1 2 1 <br />1 <br />2 <br />G <br />7 <br />MOD: CANADIAN SOLAR INC. CS3N <br />395MS-BLK <br />INV: ENPHASE ENERGY INC. <br />IQ8PLUS-72-2-US 240V <br />(1 BRANCH X 7 MICRO-INV) <br />1 2 1 <br />1 <br />2 <br />G <br />7 <br />MOD: CANADIAN SOLAR INC. CS3N <br />395MS-BLK <br />INV: ENPHASE ENERGY INC. <br />IQ8PLUS-72-2-US 240V <br />(1 BRANCH X 7 MICRO-INV) <br />1 <br />2 <br />1 <br />2 <br />G <br />N <br />JUNCTION BOX <br />600V, NEMA 3R <br />UL LISTED <br />TO CONSUMPTION CTs <br />G <br />N <br />GATEWAY <br />CT <br />CELL <br />MODEM <br />WIRELESS <br />COMMS TO SYSTEM <br />CONTROLLER <br />- <br />- <br />20A(N) <br />20A(N) <br />IQ COMBINER 4/4C <br />G <br />N <br />1 <br />2 <br />1 <br />2 <br />ON OFF <br />PV VISIBLE LOCKABLE <br />LABELED DISCONNECT <br />(30A UNFUSED 1PH 240VAC) <br />G <br />N <br />LOADS MAIN <br />1 <br />1 <br />2 <br />1 <br />NFT <br />GEN <br />21 2 1 2 <br />2 <br />ESS <br /> (NO3) <br />GENLOADS <br />MAINPV <br />(NC3 NC4) <br />RSD <br />GEN BREAKER <br />TO GATEWAY <br />ESS <br />PV <br />40A <br />15A <br />20A <br />25A <br />IQ SYSTEM CONTROLLER 2 <br />LOADS BREAKER: 100A <br />100A <br />SC01 <br />ENPHASE SYSTEM <br />SHUTDOWN SWITCH <br />G <br />1 <br />2 <br />G <br />1 <br />2 <br />G <br />1 <br />2 <br />G <br />1 <br />2 <br />G <br />1 <br />2 <br />G <br />1 <br />2 <br />G <br />1 <br />2 <br />G <br />1 <br />2 <br />G <br />1 <br />2 <br />G <br />1 <br />2 <br />G <br />1 <br />2 <br />G <br />1 <br />2 <br />G <br />1 <br />2 <br />G <br />1 <br />2 <br />G <br />1 <br />2 <br />G <br />1 <br />2 <br />G <br />1 <br />2 <br />G <br />1 <br />2 <br />BT01 <br />(1) ENPHASE IQ BATTERY 10T <br />G <br />N <br />SUBPANEL (NEW) <br />BUS RATING: 125A <br />G <br />N <br />TO <br />UTILITY <br />GRIDM <br />200A(N) <br />100A(N) <br />MAIN SERVICE PANEL <br />(NEW, TOP-FED) <br />BUS RATING: 225A (N) <br />MAIN BREAKER: 200A (N) <br />BI-DIRECTIONAL <br />UTILITY METER <br />METER NO: <br />222013-606723 <br />UTILITY: SOUTHERN <br />CALIFORNIA EDISON CO <br />SERVICE: 240V 60HZ 1PH <br />12 AWG Q-CABLE <br />06 AWG Cu BARE G (BOND RACKING) <br />12 AWG Q-CABLE <br />06 AWG Cu BARE G (BOND RACKING) <br />CT <br />MS-01 <br />MS-01 <br />MCB-01 <br />MCB-01 <br />LC-01 <br />LC-01 <br />SP-01 <br />AC wire details <br />Wire Min Ampacity Live Neutral Ground Min EMT <br />MS-01 10.59A 12 AWG (Q-Cable) -06 AWG BARE <br />(NOT IN CONDUIT)- <br />MCB-01 10.59A (2) 10 AWG THWN-2 - 08 AWG THWN-2 1/2 in <br />LC-01 21.18A (2) 10 AWG THWN-2 10 AWG THWN-2 10 AWG THWN-2 1/2 in <br />SP-01 100A (loads) (2) 02 AWG THWN-2 02 AWG THWN-2 08 AWG THWN-2 1-1/4 in <br />BT01 20A (OCPD) (2) 10 AWG THWN-2 - 10 AWG THWN-2 1/2 in <br />SC01 100A (OCPD) (2) 02 AWG THWN-2 02 AWG THWN-2 08 AWG THWN-2 1-1/4 in <br />UTILITY FEED + TOTAL BACKFEED <br />225A + 41A = 266A <br />LESS OR EQUAL TO <br />BUS RATING x 120% <br />225A x 120% = 270A <br />INTERCONNECTION 120% RULE <br />(MAIN PANEL) <br />CALCULATION ENSURES BUS IS <br />SAFE REGARDLESS OF LOADS <br />Isc(25°C) = 11.44A, Tisc = 0.050%/°C <br />Isc(T) = Isc(25°C) x [1 + Tisc x (T-25°C)] <br />Isc(3°C) = 11.31A, Isc(28°C) = 11.46A <br />Voc(25°C) = 44.30V, Tvoc = -0.260%/°C <br />Voc(T) = Voc(25°C) x [1 + Tvoc x (T-25°C)] <br />Voc(3°C) = 46.83V, Voc(28°C) = 43.95V <br />EXTREME CASE MODULE OUTPUT <br />(Canadian Solar Inc. CS3N 395MS-BLK) <br />ELECTRICAL NOTES <br />1) ALL GROUNDING TO COMPLY WITH NEC 690.47. <br />2) ROOFTOP CONDUIT SHALL BE LOCATED MIN. 7/8" ABOVE ROOF SURFACE. <br />3) ALL TERMINALS SHALL BE MIN. 75°C RATED. <br />4) IQ GATEWAY BREAKER DETERMINED AT FACTORY BY MANUFACTURER (10A or 15A). <br />5) FOR IQ GATEWAY: USE SINGLE CT FOR PV PRODUCTION (L1 FROM ALL PV BRANCH CIRCUITS). USE DOUBLE CTs FOR <br />CONSUMPTION (L1 AND L2 FEEDING MSP MAIN BREAKER, SERVICE SIDE). <br />6) WHEN IQ SYSTEM CONTROLLER 2 NOT AT SERVICE ENTRANCE, REMOVE N-G JUMPER WIRE FROM CONTROLLER. <br />7) SINGLE LARGEST BREAKER, BASELINE LOAD, AND LRA OF LARGEST LOAD IN BACKUP LOAD PANEL CANNOT EXCEED <br />STORAGE (ESS) OUTPUT CAPACITY, PER NEC 710.15. <br />8) IQ SYSTEM CONTROLLER 2 MAIN INPUT AND OUTPUT LUGS RATED FOR #1-350 KCMIL, FOR WIRES SMALLER THAN #1 <br />REMOVE LUG AND USE AN APPROVED UL RING TERMINAL. <br />9) IQ SYSTEM CONTROLLER 2 HOLD DOWN KIT NEEDED FOR ESS & PV BREAKER, PER NEC 705.12(E). <br />10) THE CITY REQUIRES TWO SOURCES OF GROUND - UFER, TWO GROUND RODS OR COLD WATER GAS BOND. <br />11) HOLD DOWN KIT BRHDK 125 IS REQUIRED PER NEC 705.12(E) <br />TO PRODUCTION CTs <br />DIG ALERT (811) IS TO BE CONTACTED AND COMPLIANCE WITH EXCAVATION SAFETY IN <br />ACCORDING WITH GOVERNMENT CODE 4216 WILL BE FOLLOWED, PRIOR TO ANY <br />EXCAVATION TAKING PLACE. <br />NOTE: SPLICING OF THE WIRE-TYPE GROUNDING ELECTRODE SHALL BE PERMITTED <br />ONLY BY IRREVERSIBLE COMPRESSION-TYPE CONNECTORS LISTED AS GROUNDING <br />AND BONDING EQUIPMENT OR BY THE EXOTHERMIC WELDING METAL WATER PIPING <br />SYSTEM INSTALLED IN OR ATTACHED TO A BUILDING OR STRUCTURE SHALL BE <br />BONDED PER CEC TABLE 250.66 AND 250.104(A)(1) <br />THE SURGE PROTECTION DEVICE (SPD) SHALL COMPLY WITH 2022 CALIFORNIA <br />ELECTRICAL CODE 230.67 THE SPD MUST BE EITHER TYPE 1 OR TYPE 2. <br />SP <br />D <br />PV BREAKER SHALL BE <br />FURTHEST POSITION <br />AWAY FROM MAIN <br />BREAKER PERCEC <br />705.12(B)(2)(3)(b). <br />SURGE PROTECTION DEVICE <br />REV <br />SHEET NAME <br />SHEET SIZE <br />SHEET NUMBER <br />ANSI B <br />DATE DESCRIPTION <br />REVISIONS <br />PV-4 <br />HOMEOWNER INFO <br />11" X 17" <br />SIGNATURE & SEAL <br />THREE LINE <br />DIAGRAM <br />CONTRACTOR: COMPLETE SOLARIA <br />ADDRESS: 3000 EXECUTIVE PKWY, SUITE <br />504, SAN RAMON, CA 94583 <br />PHONE: 8772994943 <br />LICENSE #: 961988 <br />J <br />O <br />S <br />E <br /> <br />G <br />O <br />M <br />E <br />Z <br />28 <br />1 <br />7 <br /> <br />W <br /> <br />B <br />R <br />O <br />O <br />K <br /> <br />S <br />T <br />, <br />SA <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />4 <br />, <br /> <br />U <br />S <br />A <br />AP <br />N <br />: <br /> <br />1 <br />0 <br />9 <br />- <br />7 <br />4 <br />1 <br />- <br />1 <br />6 <br /> <br /> <br /> <br />PH <br />O <br />N <br />E <br />: <br /> <br />7 <br />1 <br />4 <br />3 <br />2 <br />1 <br />3 <br />5 <br />5 <br />4 <br />EM <br />A <br />I <br />L <br />: <br /> <br />j <br />o <br />s <br />e <br />g <br />o <br />m <br />e <br />z <br />1 <br />0 <br />1 <br />7 <br />5 <br />7 <br />@ <br />g <br />m <br />a <br />i <br />l <br />. <br />c <br />o <br />m <br />SCALE: NTS <br />ELECTRICAL THREE LINE DIAGRAM <br />GROUND ROD (N) GROUND <br />ROD (5/8", 8') <br />PLACED 6'-0" APPART <br />CONNECT TO COLD <br />WATER WITHIN 5' <br />PLACED 6'-0" APPARTEXISTING GROUNDING <br />ELECTROD SYSTEM TO <br />EARTH <br />NEC 250.52,250.53(A) <br />NEW #4 CU AUXILIARY GROUND ROD <br />SHOULD BE MORE THAN 6 FEET FROM <br />THE EXISTING GEC <br /> MAIN PANEL REPLACEMENT: EXISTING 100 AMP MAIN PANEL <br /> WITH 100 AMP MAIN BREAKER TO BE REPLACED WITH NEW <br /> 225 AMP MAIN PANEL WITH NEW 200 AMP MAIN BREAKER. <br />The maximum current output from the battery in <br />backup mode is 16A. There can be no single <br />circuits in the backup loads panel that exceeds <br />20A nor a load greater than 16A. CEC 705.28(A), <br />710.15(A) <br />2817 W Brook St - <br />201822693/19/2024