Laserfiche WebLink
SYSTEM SUMMARY STC (5.530 kW DC / 4.060 kW AC) <br />STC DC: (14) 395W = 5.530 kW <br />STC AC: (14) 290W = 4.060 kW <br />STORAGE: (1) 3.84kW 10.1kWh <br />●(14) CANADIAN SOLAR INC. CS3N 395MS-BLK MODULES <br />●(14) ENPHASE ENERGY INC. IQ8PLUS-72-2-US 240V MICROINVERTERS <br />●(1) ENPHASE ENERGY INC. IQ BATTERY 10T FOR USMXCA BATTERIES <br />●(1) ENPHASE IQ SYSTEM CONTROLLER 2 <br />●2x BRANCHES OF 7 CONNECTED IN PARALLEL <br />AC wire details <br />WireID #Modules Nominal <br />Voltage <br />Backfeed *1.25 <br />/cond. set <br />Min <br />OCPD <br />Total <br />Power <br />Conductor <br />sets <br />ccConductors <br />/conduit <br />Expected <br />max temp <br />Adjusted ampacity (ampacity x temp <br />derate x conduit fill derate) <br />Conductor & <br />neutral size <br />EGC size <br />(Cu) <br />Conductor <br />metal <br />Max <br />length V drop Min EMT <br />size <br />MS-01 7 240 V 10.59 A 20 A 2.0 kW 1 - 28 25 x 1.00 x - = 25.00 A 12 AWG (Q-Cable)06 AWG BARE <br />(NOT IN CONDUIT)Cu 50 ft 0.60 %- <br />MCB-01 7 240 V 10.59 A 20 A 2.0 kW 1 2 28 35 x 1.00 x 1.00 = 35.00 A 10 AWG THWN-2 08 AWG THWN-2 Cu 50 ft 0.36 %1/2 in <br />LC-01 14 240 V 21.18 A 25 A 4.1 kW 1 2 28 35 x 1.00 x 1.00 = 35.00 A 10 AWG THWN-2 10 AWG THWN-2 Cu 10 ft 0.14 %1/2 in <br />SP-01 14 240 V 41.18 A 100 A 7.9 kW 1 2 28 100 x 1.00 x 1.00 = 100.00 A 02 AWG THWN-2 08 AWG THWN-2 Cu 10 ft 0.06 %1-1/4 in <br />UTILITY FEED + TOTAL BACKFEED <br />225A + 41A = 266A <br />LESS OR EQUAL TO <br />BUS RATING x 120% <br />225A x 120% = 270A <br />INTERCONNECTION 120% RULE <br />(MAIN PANEL) <br />CALCULATION ENSURES BUS IS <br />SAFE REGARDLESS OF LOADS <br />Isc(25°C) = 11.44A, Tisc = 0.050%/°C <br />Isc(T) = Isc(25°C) x [1 + Tisc x (T-25°C)] <br />Isc(3°C) = 11.31A, Isc(28°C) = 11.46A <br />Voc(25°C) = 44.30V, Tvoc = -0.260%/°C <br />Voc(T) = Voc(25°C) x [1 + Tvoc x (T-25°C)] <br />Voc(3°C) = 46.83V, Voc(28°C) = 43.95V <br />EXTREME CASE MODULE OUTPUT <br />(Canadian Solar Inc. CS3N 395MS-BLK) <br />ELECTRICAL NOTES <br />1) ALL EQUIPMENT TO BE LISTED BY UL OR OTHER NRTL, AND LABELED FOR ITS APPLICATION. <br />2) ALL CONDUCTORS SHALL BE COPPER, RATED FOR 600V AND 90°C WET ENVIRONMENT. <br />3) WIRING, CONDUIT, AND RACEWAYS MOUNTED ON ROOFTOPS SHALL BE ROUTED DIRECTLY TO, AND LOCATED AS CLOSE AS POSSIBLE TO THE NEAREST RIDGE, HIP, OR VALLEY. <br />4) WORKING CLEARANCES AROUND ALL NEW AND EXISTING ELECTRICAL EQUIPMENT SHALL COMPLY WITH NEC 110.26. <br />5) DRAWINGS INDICATE THE GENERAL ARRANGEMENT OF SYSTEMS. CONTRACTOR SHALL FURNISH ALL NECESSARY OUTLETS, SUPPORTS, FITTINGS AND ACCESSORIES TO FULFILL APPLICABLE CODES AND STANDARDS. <br />6) WHERE SIZES OF JUNCTION BOXES, RACEWAYS, AND CONDUITS ARE NOT SPECIFIED, THE CONTRACTOR SHALL SIZE THEM ACCORDINGLY. <br />7) ALL WIRE TERMINATIONS SHALL BE APPROPRIATELY LABELED AND READILY VISIBLE. <br />8) MODULE GROUNDING CLIPS TO BE INSTALLED BETWEEN MODULE FRAME AND MODULE SUPPORT RAIL, PER THE GROUNDING CLIP MANUFACTURER'S INSTRUCTION. <br />9) MODULE SUPPORT RAIL TO BE BONDED TO CONTINUOUS COPPER G.E.C.VIA WEEB LUG OR ILSCO GBL-4DBT LAY-IN LUG. <br />10) PV EQUIPMENT SHALL BE DESIGNED AND INSTALLED IN ACCORDANCE WITH NEC 690. <br />11) EXACT LOCATION OF AUXILIARY GROUNDING TO BE DETERMINED AT TIME OF INSTALL. <br />12) EXISTING WIRES MUST BE REPLACED IF SMALLER THAN LISTED MINIMUM SIZES PER NEC 310.15(B)(16). <br />13) IQ GATEWAY BREAKER DETERMINED AT FACTORY BY MANUFACTURER (10A or 15A). <br />14) FOR IQ GATEWAY: USE SINGLE CT FOR PV PRODUCTION (L1 FROM ALL PV BRANCH CIRCUITS). USE DOUBLE CTs FOR CONSUMPTION (L1 AND L2 FEEDING MSP MAIN BREAKER, SERVICE SIDE). <br />15) WHEN IQ SYSTEM CONTROLLER 2 NOT AT SERVICE ENTRANCE, REMOVE N-G JUMPER WIRE FROM CONTROLLER. <br />16) SINGLE LARGEST BREAKER, BASELINE LOAD, AND LRA OF LARGEST LOAD IN BACKUP LOAD PANEL CANNOT EXCEED STORAGE (ESS) OUTPUT CAPACITY, PER NEC 710.15. <br />17) IQ SYSTEM CONTROLLER 2 MAIN INPUT AND OUTPUT LUGS RATED FOR #1-350 KCMIL, FOR WIRES SMALLER THAN #1 REMOVE LUG AND USE AN APPROVED UL RING TERMINAL. <br />18) IQ SYSTEM CONTROLLER 2 HOLD DOWN KIT NEEDED FOR ESS & PV BREAKER, PER NEC 705.12(E). <br />19) THE CITY REQUIRES TWO SOURCES OF GROUND - UFER, TWO GROUND RODS OR COLD WATER GAS BOND. <br />20) HOLD DOWN KIT BRHDK 125 IS REQUIRED PER NEC 705.12(E) <br />ROOF COVERAGE TABLE <br />●TOTAL AREA: (14) 76.4" x 41.3" = 306 SF <br />●TOTAL ROOF AREA: 2526 SF <br />●ROOF AREA COVERED: 306 SF / 2526 SF = 12.1% <br />REV <br />SHEET NAME <br />SHEET SIZE <br />SHEET NUMBER <br />ANSI B <br />DATEDESCRIPTION <br />REVISIONS <br />PV-5 <br />HOMEOWNER INFO <br />11" X 17" <br />SIGNATURE & SEAL <br />WIRING <br />CALCULATIONS <br />CONTRACTOR: COMPLETE SOLARIA <br />ADDRESS: 3000 EXECUTIVE PKWY, SUITE <br />504, SAN RAMON, CA 94583 <br />PHONE: 8772994943 <br />LICENSE #: 961988 <br />JO <br />S <br />E <br /> <br />G <br />O <br />M <br />E <br />Z <br />28 <br />1 <br />7 <br /> <br />W <br /> <br />B <br />R <br />O <br />O <br />K <br /> <br />S <br />T <br />, <br />SA <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />4 <br />, <br /> <br />U <br />S <br />A <br />AP <br />N <br />: <br /> <br />1 <br />0 <br />9 <br />- <br />7 <br />4 <br />1 <br />- <br />1 <br />6 <br /> <br /> <br /> <br /> <br />P <br />H <br />O <br />N <br />E <br />: <br /> <br />7 <br />1 <br />4 <br />3 <br />2 <br />1 <br />3 <br />5 <br />5 <br />4 <br />EM <br />A <br />I <br />L <br />: <br /> <br />j <br />o <br />s <br />e <br />g <br />o <br />m <br />e <br />z <br />1 <br />0 <br />1 <br />7 <br />5 <br />7 <br />@ <br />g <br />m <br />a <br />i <br />l <br />. <br />c <br />o <br />m <br />SCALE: NTS <br />WIRING CALCULATIONS <br />2817 W Brook St - <br />201822693/19/2024