Laserfiche WebLink
COMPLETE SOLAR <br />3000 EXECUTIVE PKWY,STE 504 <br />SAN RAMON, CA 94583 <br />LICENSE TYPE C10 <br />LICENSE # 961988 <br />PHONE # (877) 299-4943 <br />DESIGNED BY: BRAD NEWMAN <br />SITE INFORMATION: <br />MAX CONTINUOUS AC SYSTEM SIZE: <br />6.96 kW <br />DC SYSTEM SIZE: 8.4 kW <br />(24) LONGI LR4-60HPB-350M <br />MODULES <br />(24) ENPHASE IQ8PLUS-72-2-US <br />INVERTER(S) <br />MOUNTING EQUIPMENT: <br />UNIRAC SM & UNIRAC - FLASHLOC <br />COMP <br />LOPEZ <br />ROBERTO LOPEZ PROJECT <br />2826 RIDGEWOOD ST <br />SANTA ANA, CA 92705 <br />LAT , LONG: 33.7761031, <br />-117.8412164 <br />COVER SHEET <br />VICINITY MAP: <br />AERIAL VIEW: <br />SHEET INDEX:GENERAL NOTES: <br />1. ALL ELECTRICAL MATERIALS SHALL BE NEW AND LISTED BY RECOGNIZED ELECTRICAL <br />TESTING LABORATORY CUSTOM MADE EQUIPMENT SHALL HAVE COMPLETE TEST DATA <br />SUBMITTED BY THE MANUFACTURER ATTESTING TO ITS SAFETY <br />2. OUTDOOR EQUIPMENT SHALL BE AT LEAST NEMA 3R RATED <br />3. ALL METALLIC EQUIPMENT SHALL BE GROUNDED <br />4. ALL SPECIFIC WIRING IS BASED ON THE USE OF COPPER. <br />5. CONTRACTOR SHALL OBTAIN ELECTRICAL PERMITS PRIOR TO INSTALLATION AND SHALL <br />COORDINATE ALL INSPECTIONS, TESTING COMMISSIONING AND ACCEPTANCE WITH THE CLIENT, <br />UTILITY CO. AND CITY INSPECTORS AS NEEDED. <br />6. THE ELECTRICAL CONTRACTOR SHALL VERIFY THE EXACT LOCATIONS OF SERVICE POINTS <br />AND SERVICE SIZES WITH THE SERVING UTILITY COMPANY AND COMPLY WITH ALL UTILITY <br />COMPANIES REQUIREMENTS. IF THE SOLAR BACK FED BREAKER IS VOER THE BUSS SIZE 20% <br />LIMIT, CONTRACTOR SHALL INCLUDE THE COST TO REPLACE MAIN BREAKER OR ENLARGE MAIN <br />CAPACITY. <br />7. DRAWINGS ARE DIAGRAMMATIC ONLY, ROUTING OF RACEWAYS SHALL BE OPTION OF THE <br />CONTRACTOR UNLESS OTHERWISE NOTED AND SHALL BE COORDINATED WITH OTHER TRADES. <br />8. IF THE ROOF MATERIAL OR ROOF STRUCTURE NOT ADEQUATE FOR PV INSTALLATION, <br />CALL ENGINEER PRIOR TO INSTALL. THE CONTRACTOR IS RESPONSIBLE TO VERIFY THAT THE <br />ROOF IS CAPABLE OF WITHSTANDING THE EXTRA WEIGHT. <br />9. IF THE DISTANCES FOR CABLE RUNS ARE DIFFERENT THAN SHOWN, THE CONTRACTOR <br />SHALL NOTIFY THE ELECTRICAL ENGINEER TO VALIDATE THE SIRE SIZE. FINAL DRAWINGS WILL <br />BE RED-LINED AND UPDATED AS APPROPRIATE. <br />10. WHENEVER A DISCREPANCY IN QUALITY OF EQUIPMENT ARISES ON THE DRAWING OR <br />SPECIFICATIONS, THE CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING AND INSTALLING <br />ALL MATERIAL AND SERVICES REQUIRED BY THE STRICTEST CONDITIONS NOTED ON THE <br />DRAWINGS OR IN THE SPECIFICATIONS TO ENSURE COMPLETE COMPLIANCE AND LONGEVITY OF <br />THE OPERABLE SYSTEM REQUIRED BY THE ARCHITECT/ENGINEERS. <br />11. ALL BROCHURES, OPERATION MANUALS, CATALOGS, SHOP DRAWINGS, ETC. SHALL BE <br />HANDED OVER TO OWNER'S REPRESENTATIVE AT THE COMPLETION OF WORK <br />GOVERNING CODES: <br />20 CALIFORNIA ELECTRICAL CODE <br />20 CALIFORNIA BUILDING CODE (VOL 1 & 2) <br />20 CALIFORNIA RESIDENTIAL CODE <br />20 CALIFORNIA FIRE CODE <br />20 CALIFORNIA GREEN BUILDING STANDARDS CODE <br />20 CALIFORNIA ENERGY CODE <br />20 CALIFORNIA MECHANICAL CODE <br />ALL OTHER ORDINANCE ADOPTED BY <br />THE LOCAL GOVERNING AGENCIES <br />SITE SPECIFICATIONS: <br />ZONING: <br />OCCUPANCY GROUP: <br />CONSTRUCTION TYPE: <br />NUMBER OF STORIES: <br />ROOF LAYERS: <br />FIRE SPRINKLERS PRESENT: <br />THE INSTALLATION OF SOLAR ARRAY AND <br />PHOTOVOLTAIC POWER SYSTEMS SHALL <br />COMPLY WITH THE FOLLOWING CODES: <br />AHJ: SANTA ANA <br />SCOPE OF WORK: <br />SYSTEM INFORMATION: <br />EQUIPMENT INFORMATION: <br />DATE: October 24, 2022 <br />PV ROOF MOUNT INSTALLATION OF <br />24 LONGI LR4-60HPB-350M MODULES, <br />24 ENPHASE IQ8PLUS-72-2-US INVERTER(S), <br />EXISTING 200A MAIN SERVICE PANEL WITH A MAIN BREAKER <br />(24) LONGI LR4-60HPB-350M MODULES <br />(24) ENPHASE IQ8PLUS-72-2-US INVERTER(S) <br />MOUNTING EQUIPMENT: UNIRAC SM & UNIRAC - FLASHLOC COMP - 72" O.C. <br />DC SYSTEM SIZE: 8.4 kW <br />MAX CONTINUOUS AC SYSTEM SIZE: 6.96 kWR-3 <br />RESIDENTIAL <br />V-B <br />2 <br />1 <br />N PV-1.0 <br />COMPLETE <br />SOLAR <br />PV-1.0 COVER SHEET <br />PV-2.0 SITE PLAN <br />PV-3.0 ROOF PLAN <br />PV-4.0 ROOF ATTACHMENTS <br />PV-5.0 MOUNTING DETAIL <br />PV-6.0 LINE DIAGRAM <br />PV-7.0 LABELS <br />PV-8.0 PLACARD <br />METER CONNECTION: UNDERGROUND <br />NO TRENCHING <br />UTILITY: SCE <br />(7) ROOFTOP PV J-BOX & (1) NEMA 3R JUNCTION BOX <br />(1) IQ COMBINER 4C <br />(1) 100A LOAD CENTER COMBINER PANEL <br />(1) 60A AC AC DISCONNECT <br />E DIAGRAM <br />BELS <br />ACARRRRRRRRRRRRRRRRRRRRRRRRDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDD <br />10/26/2022 <br />The scope of the plans is for the <br />installation of the solar <br />photovoltaic system only and <br />the approval is subject to <br />compliance with all applicable <br />city and state codes and <br />regulations regarding <br />construction. The approval of <br />the plans does not constitute <br />any certification of the accuracy, <br />completeness, or building permit <br />status of the existing buildings <br />and structures as shown. <br />Bldg#: 101118523 <br />Elec#: 20182301 <br />2826 N Ridgewood St- <br />101118523 & 201823013/11/2024