Laserfiche WebLink
WH <br />FD <br />FD <br />UP UP <br />UP <br />UP <br />UP <br />FIRE & LIFE SAFETY LEGEND <br />EXIT SIGN - <br />CEILING / WALL MOUNTED <br />DIRECTIONAL EXIT SIGN - <br />CEILING / WALL MOUNTED <br />1. PROVIDE FIRE EXTINGUISHERS AS SHOWN IN PLANS (MINIMUM) - FINAL LOCATIONS <br />TO BE DETERMINED BY FIRE DEPARTMENT INSPECTOR. <br />2. EXITS, EXIT ACCESS DOORS AND PATHS OF EGRESS TRAVEL THAT IS NOT <br />IMMEDIATELY VISIBLE TO THE OCCUPANTS SHALL BE MARKED BY AN APPROVED <br />EXIT SIGN THAT IS READILY VISIBLE FROM ANY DIRECTION OF EGRESS TRAVEL. <br />EXIT SIGNS SHALLL BE INTERNALLY OR EXTERNALLY ILLUMINATED. (NOTE: <br />ADDITIONAL EXITS SIGNS MAY BE REQUIRED AT TIME OF FIELD INSPECTION.) <br />3. EXIT ACCESS SHALL NOT PASS THROUGH A ROOM WHICH CAN BE LOCKED TO <br />PREVENT EGRESS <br />4. EXIT SIGNS SHALL BE INTERNALLY OR EXTERNALLY ILLUMINATED. (CBC 1013.3). <br />5. ELECTRICALLY POWERED EXIT SIGNS SHALL BE LISTED AND LABELED IN <br />ACCORDANCE WITH UL 924. (CBC SECTION 1013.5.) <br />6. EMERGENCY POWER SUPPLY TO ILLUMINATE EXIT SIGNS FOR A DURATION OF NOT <br />LESS THAN 90 MINUTES. <br />7. IN THE EVENT OF A POWER SUPPLY FAILURE, AN EMERGENCY ELECTRICAL <br />SYSTEM SHALL AUTOMATICALLY ILLUMINATE AISLES, LOBBY, CORRIDOR AND <br />EXTERIOR DOOR LANDING. THE EMERGENCY POWER SYSTEM SHALL PROVIDE <br />POWER FOR A DURATION OF NOT LESS THAN 90 MINUTES AND SHALL CONSIST OF <br />STORAGE BATTERIES, UNIT EQUIPMENT OR AN ON-SITE GENERATOR. INITIAL <br />ILLUMINATION AVERAGE OF 1 FOOT-CANDLE AND A MINIMUM 0.1 FOOT-CANDLE AT <br />FLOOR LEVEL (CBC 1008.3.4). <br />8. ALL TACTILE SIGNAGE SHALL BE MOUNTED AT LATCH SIDE OF DOOR. <br />TACTILE EXIT SIGN, SEE <br />NUMBER OF OCCUPANTS EXITING SPACE <br />.... .EXIT <br />EXISTING WALL-MOUNTED FIRE-EXTINGUISHER, <br />RATED 2-A/10B/C <br />10 <br />INDICATES PANIC HARDWARE AT DOORPANIC <br />FE <br />MAX OCCUPANCY SIGN, SEE OCC <br />ASSISTIVE LISTENING SYSTEM SIGN, SEE ALS <br />ASSISTIVE LISTENING SYSTEM NOTES <br />1. PROVIDE ASSISTIVE LISTENING SYSTEM AT ASSEMBLY AREAS, CONFERENCE AND MEETING <br />ROOMS IN ACCORDANCE WITH CBC SECTION 11B-219 AND 11B-706 <br />2. TOTAL NUMBER OF RECEIVERS SHALL BE EQUAL TO 4% TOTAL NUMBER OF SEATS, BUT NO <br />LESS THAN 2 <br />3. 25% OF MINIMUM RECEIVERS PROVIDED, BUT NO LESS THAN TWO, SHALL BE HEARING-AID <br />COMPATIBLE PER 11B-219.3 <br />4. AREAS WITH SYSTEM SHALL BE WITHIN 50' VIEWING DISTANCE OF STAGE OR PLAYING AREA <br />AND HAVE COMPLETE VIEW OF STAGE OR PLAYING AREA, WHERE APPLICABLE. <br />5. RECEIVERS REQUIRED FOR USE WITH AN ASSISTIVE LISTENING SYSTEM SHALL INCLUDE 1/8" <br />STANDARD MONO JACK <br />6. RECEIVERS REQUIRED TO BE HEARING-AID COMPATIBLE SHALL INTERFACE WITH TELECOILS <br />IN HEARING AIDS THROUGH THE PROVISION OF NECKLOOPS <br />7. ASSISTIVE LISTENING SYSTEMS SHALL BE CAPABLE OR PROVIDING A SOUND PRESSURE <br />LEVEL OF 110 dB MINIMUM AND 118 dB MAXIMUM WITH A DYNAMIC RANGE ON THE VOLUME <br />CONTROL OF 50 dB. <br />8. THE SIGNAL-TO-NOISE RATIO FOR INTERNALLY GENERATED NOISE IN ASSISTIVE LISTENING <br />SYSTEMS SHALL BE 18dB MINIMUM <br />9. PEAK CLIPPING SHALL NOT EXCEED 18 dB OF CLIPPING RELATIVE TO PEAKS OF SPEECH <br />FIRE & LIFE SAFETY NOTES <br />THIS PROJECT CONSISTS OF AN EXISTING ONE-STORY CONCRETE AND WOOD FRAMED STRUCTURE. <br />BUILDING IS SEPARATED FROM ADJACENT BUILDING BY EXISTING 3-HOUR FIRE WALL -SEE DIAGRAM <br />BELOW. <br />THE TENANT SPACE IS EQUIPPED WITH AN EXISTING NFPA 13 AUTOMATIC FIRE SPRINKLER SYSTEM <br />THROUGHOUT. <br />CONSTRUCTION TYPE:III-B, FULLY SPRINKLERED (NFPA 13) <br />OCCUPANCY CLASSIFICATION: A3, B, S2 (NON-SEPARATED PER CBC 508.3) <br />BUILDING AREA: <br /> TENANT AREA OF WORK <br />GROUND FLOOR = 19,850 SF <br />SECOND FLOOR = 3,688 SF <br />TOTAL 23,538 SF <br />HEIGHT (PER CBC TABLE 504.3):ALLOWABLE ACTUAL <br />60' *22'-0 (EXISTING) <br />*USE A OCCUPANCY; MOST RESTRICTIVE <br />STORIES (PER CBC TABLE 504.4): ALLOWABLE ACTUAL <br />2*2 (EXISTING) <br />*USE A-3 OCCUPANCY; MOST RESTRICTIVE <br />ALLOWABLE AREA (PER CBC TABLE 506.2):ALLOWABLE ACTUAL <br />24,000 SF PER FLOOR**19,850 SF (GROUND) <br />3,688 SF (SECOND) <br />48,000 SF **23,538 SF (TOTAL) <br />**Aa = (At + (NS X If) X Sa <br />=(18,000 + (6, 000 X 1 ) X 2 <br />= 48,000 (24,000 PER FLOOR) <br />EXISTING BUILDING CODE ANALYSIS <br />(E) <br />OFFICE <br />205 (E) <br />OFFICE <br />206 <br />(E) <br />OFFICE <br />204 <br />(E) <br />OFFICE <br />203 <br />(E) <br />OFFICE <br />202 <br />(E) <br />HALLWAY <br />201 <br />(E) STOR. <br />207 <br />3 <br />2 <br />4 <br />3 <br />2 <br />9 <br />25 <br />.... .EXIT <br />1 <br />VOID <br />2915 2909 <br />23,538 SF <br />2-STORY <br />A-3 OCCUPANCY <br />(AREA OF WORK) <br />COMPASS CHURCH <br />11,944 SF <br />1-STORY <br />B OCCUPANCY <br />WATER TECHNIQUES <br />2917 <br />11,944 SF <br />1-STORY <br />B OCCUPANCY <br />PRIMEGEN BIOTECH <br />EXISTING 3-HOUR FIRE WALL <br />(E) STAIR <br />ADJACENT TENANT (NOT IN SCOPE)(E) 3-HOUR FIRE WALL(E) 3-HOUR FIRE WALL <br />NOTES: <br />• SEE SITE PLAN FOR ASSUMED PROPERTY LINE INFORMATION <br />• EXISTING EXTERIOR WALLS ARE 8" THICK CONCRETE TILT-UP, WHICH HAVE A FIRE-RESISTANCE RATING OF 4 HOURS PER CBC TABLE 721(2) <br />• FIRE WALL EXTENDS 18" PAST EXTERIOR SURFACE OF EXTERIOR WALL PER CBC 706.5 (EAST SIDE) <br />• FIRE WALL PERMITTED TO TERMINATE AT INTERIOR SURFACE OF EXTERIOR WALL (WEST SIDE), PROVIDED EXTERIOR WALL HAS A 1-HOUR MIN. FIRE- <br />RESISTANCE RATING FOR A HORIZONTAL DISTANCE OF NOT LESS THAN 4 FEET, WITH NO OPENINGS -PER CBC 706.5 EXCEPTION 1 <br />• FIRE-RESISTANCE RATING OF ADJACENT EXTERIOR WALLS IS 1-HOUR MIN.; WITH NO OPENINGS, FOR A MINIMUM OF 4 FEET FROM THE INTERSECTION <br />OF THE FIRE WALL TO EXTERIOR WALL (AS REQUIRED BY CBC 706.5.1 #1) <br />(E) <br />OFFICE <br />109 <br />(E) <br />NURSERY <br />107 <br />(E) VOID <br />108 <br />(E) <br />MEETING <br />ROOM <br />106 <br />(E) <br />MEETING <br />ROOM <br />105 <br />(E) I.T. <br />ROOM <br />110 <br />(E) <br />MEETING <br />ROOM <br />111 <br />(E) <br />MEETING <br />ROOM <br />112 <br />(E) <br />LUNCH <br />ROOM <br />113 <br />(E) <br />MEETING <br />ROOM <br />104 <br />(E) F.R. <br />104A <br />(E) <br />MEETING <br />ROOM <br />103 <br />(E) <br />HALLWAY <br />102 <br />(E) <br />LOBBY <br />118 <br />(E) <br />MEETING <br />ROOM <br />114 <br />(E) JAN <br />115 <br />(E) MEN <br />116 <br />(E) <br />WOMEN <br />117 <br />(E) <br />AUDITORIUM <br />119 <br />(E) <br />STORAGE <br />120 <br />(E) <br />STORAGE <br />121 <br />YOUTH <br />ROOM <br />123 <br />(E) <br />ELECT. <br />124 <br />(E) <br />LOBBY <br />101 <br />(E) STAIR <br />41 <br />23 <br />16 <br />19 <br />18 19 <br />3 <br />2 <br />18 <br />18 <br />2 <br />20 <br />606 <br />5 <br />1 <br />5 <br />103 <br />104 <br />367 <br />87 <br />173 173 <br />297 149 297 <br />EXIT WIDTH RQ'D = 297 X 0.2 = 59.4" <br />EXIT WIDTH PROVIDED = 72" <br />EXIT WIDTH RQ'D = 149 X 0.2 = 29.8" <br />EXIT WIDTH PROVIDED = 36" <br />301 <br />153 <br />EXIT WIDTH RQ'D = 153 X 0.2 = 30.6" <br />EXIT WIDTH PROVIDED = 36" <br />EXIT WIDTH RQ'D = 301 X 0.2 =60.2" <br />EXIT WIDTH PROVIDED = 72" <br />25 <br />NOTE: DESIGN PROPOSES MULTIPLE EXITS WITH NO SINGLE WELL-DEFINED “MAIN EXIT”. <br />THEREFORE, EXITS HAVE BEEN DISTRIBUTED AROUND THE PERIMETER OF THE BUILDING AS <br />SHOWN, TO MEET REQUIREMENTS PER CBC 1029.2. <br />FE <br />FE <br />FE <br />FE <br />FE <br />PANIC <br />PANIC <br />PANIC PANIC PANIC <br />PANIC PANIC <br />PANIC <br />EXISTING 3-HOUR FIRE WALL <br />OVERALL BUILDING DIAGONAL = 216'-0" <br />OVERALL BUILDING EXIT SEPARATION = 121'-10" > 1/3 (216'-0") <br />AUDITORIUM DIAGONAL = 82'-8" <br />AUDITORIUM EXIT SEPARATION = 51'-8" > 1/3 (82'-8") <br />PANIC <br />174 <br />NOTE: STORAGE ROOM DOES NOT <br />CONTAIN ANY STORAGE ITEMS TALLER <br />THAN 6 FEET, AND NO CHEMICALS WILL BE <br />STORED OR USED WITHOUT PROPER <br />PERMISSION FROM OCFA. <br />207 <br />EXIT WIDTH RQ'D = 104 X 0.2 = 20.8" <br />EXIT WIDTH PROVIDED = 36" <br />OVERALL DIAGONAL = 57'-2" <br />EXIT SEPARATION = <br />43'-3" > 1/3 (57'-2") <br />EXIT WIDTH RQ'D = 103 X 0.2 = 20.6" <br />EXIT WIDTH PROVIDED = 36" <br />PANIC <br />PANIC <br />.... .EXIT (E) <br />(E) <br />.... .EXIT <br />OCC <br />ALS <br />(N) <br />(N) <br />(N) <br />(N) <br />(E) <br />(E) <br />11 <br />A5.1 <br />12 <br />A5.1 <br />13 <br />A5.1 <br />M. STEVEN <br />CAMP <br />C-18,407 <br />JUN. 30, 2025 <br />RENEWAL DATESTATEOFCALIFORNIA <br />LICENSED A RCHITECTM. STEVEN <br />CAMP <br />C-18,407 <br />JUN. 30, 2025 <br />RENEWAL DATESTATEOFCALIFORNIA <br />LICENSED A RCHITECT <br />PROJECT ARCHITECT: <br />PROJECT MANAGER: <br />DRAWN BY: <br />PROJECT NUMBER: <br />All ideas, designs and plans indicated or represented <br />by these drawings are owned by and are the property <br />of Elements Architecture, Inc. and were created and <br />developed for use in connection with the specified <br />project. None of such ideas, designs, or plans shall <br />be used for any purpose whatsoever without the <br />written permission of Elements Architecture. <br />Elements Architecture, Inc. <br />PROJECT NAME: <br />NO.DESCRIPTION DATE <br />M. Steven Camp, AIA <br />Scott Holland, AIA <br />PROJECT ADDRESS: <br />SHELLEY MACDONALD <br />EA <br />SHELLEY MACDONALD <br />1/ <br />9 <br />/ <br />2 <br />0 <br />2 <br />5 <br /> <br />8 <br />: <br />2 <br />2 <br />: <br />1 <br />4 <br /> <br />A <br />M <br />21.105 <br />TENANT <br />IMPROVEMENT <br />(YOUTH ROOM) <br />2909 DAIMLER STREET <br />SANTA ANA, CA 92705 <br />A0.1 <br />CODE ANALYSIS & <br />EGRESS PLAN <br />COMPASS BIBLE CHURCH, <br />TUSTIN SANTA ANA <br />BUILDING OCCUPANT LOAD CALCULATIONS AND EGRESS SCHEDULE - GROUND FLOOR <br />ROOM OCCUPANT LOAD (PER TABLE 1004.1.2)EXITING <br />NO. NAME SQ. FT. OCCUPANCY FUNCTION OF SPACE <br />OCCUPANT LOAD <br />FACTOR <br />NO. OF <br />OCCUPANTS <br />ONE EXIT - MAX <br />OCCUPANT LOAD PER <br />OCCUPANCY <br />MIN. NO. OF <br />EXITS <br />MINIMUM EXITING DOOR WIDTH <br />(IN INCHES) <br />PROVIDED EXITING DOOR WIDTH (IN <br />INCHES) <br />101 (E) LOBBY 202 SF A3 Assembly (Concentrated) 5 40.4 49 1 8.1 324 <br />102 (E) HALLWAY 3,756 SF - (none) <br />103 (E) MEETING ROOM 333 SF A3 Assembly (Unconcentrated) 15 22.2 49 1 4.4 36 <br />104 (E) MEETING ROOM 237 SF A3 Assembly (Unconcentrated) 15 15.8 49 1 3.2 36 <br />104A (E) F.R. 11 SF - (none) <br />105 (E) MEETING ROOM 273 SF A3 Assembly (Unconcentrated) 15 18.2 49 1 3.6 36 <br />106 (E) MEETING ROOM 260 SF A3 Assembly (Unconcentrated) 15 17.3 49 1 3.5 72 <br />107 (E) NURSERY 279 SF A3 Assembly (Unconcentrated) 15 18.6 49 1 3.7 36 <br />108 (E) VOID 98 SF (none) <br />109 (E) OFFICE 384 SF B Offices 150 2.6 49 1 0.5 36 <br />110 (E) I.T. ROOM 273 SF B Business Areas 150 1.8 49 1 0.4 36 <br />111 (E) MEETING ROOM 267 SF A3 Assembly (Unconcentrated) 15 17.8 49 1 3.6 36 <br />112 (E) MEETING ROOM 261 SF A3 Assembly (Unconcentrated) 15 17.4 49 1 3.5 36 <br />113 (E) LUNCH ROOM 193 SF B Business Areas 150 1.3 49 1 0.3 36 <br />114 (E) MEETING ROOM 294 SF A3 Assembly (Unconcentrated) 15 19.6 49 1 3.9 36 <br />115 (E) JAN 20 SF - (none) <br />116 (E) MEN 329 SF - (none) <br />117 (E) WOMEN 392 SF - (none) <br />118 (E) LOBBY 1,832 SF A3 Assembly (Concentrated) 5 366.5 49 2 73.3 324 <br />119 (E) AUDITORIUM 4,238 SF A3 Assembly (Concentrated) 7 605.5 49 3 121.1 180 <br />120 (E) STORAGE 324 SF S2 Storage and Stock Rooms 500 0.6 29 1 0.1 36 <br />121 (E) STORAGE 2,411 SF S2 Storage and Stock Rooms 500 4.8 29 1 1.0 36 <br />123 YOUTH ROOM 1,445 SF A3 Assembly (Concentrated) 7 206.4 49 2 41.3 72 <br />124 (E) ELECT. 113 SF - (none) <br />18,224 SF 1376.8 <br />PLUMBING FIXTURE ANALYSIS <br />TOTAL "A-3" OCCUPANTS = 9,921 SF/30 = 331 OCCUPANTS <br /> = 166 MEN, 166 WOMEN <br />WATER CLOSETS URINALS LAVATORIES DF <br />WO <br />M <br />E <br />N <br />ME <br />N <br />3 <br />6* <br />3 2 <br />3 <br />WATER CLOSETS URINALS LAVATORIES DF <br />WO <br />M <br />E <br />N <br /> <br />M <br />E <br />N <br />5 <br />9 <br />4 4 <br />6 <br />TO <br />T <br />A <br />L <br /> <br />R <br />E <br />Q <br />' <br />D <br />TO <br />T <br />A <br />L <br /> <br />P <br />R <br />O <br />V <br />I <br />D <br />E <br />D <br />WATER CLOSETS URINALS LAVATORIES DF <br />WO <br />M <br />E <br />N <br /> <br />M <br />E <br />N <br />1 <br />1 <br />1 1 <br />1 <br />WATER CLOSETS URINALS LAVATORIES DF <br />WO <br />M <br />E <br />N <br /> <br />M <br />E <br />N <br />2 <br />4 <br />2 1 <br />2 <br />TOTAL "B" OCCUPANTS =3,959 SF / 150 = 27 OCCUPANTS <br /> = 14 MEN, 14 WOMEN <br />* TOTAL # REQ'D FOR WOMEN SHALL NOT BE LESS THAN TOTAL <br /># WATER CLOSETS + URINALS REQ'D FOR MEN <br />1/8" = 1'-0"2SECOND FLOOR CODE ANALYSIS PLAN <br />TRUE <br />NORTH <br />PROJECT <br />NORTH <br />BUILDING OCCUPANT LOAD CALCULATIONS AND EGRESS SCHEDULE - SECOND FLOOR <br />ROOM OCCUPANT LOAD (PER TABLE 1004.1.2)EXITING <br />NO. NAME SQ. FT. OCCUPANCY FUNCTION OF SPACE <br />OCCUPANT LOAD <br />FACTOR <br />NO. OF <br />OCCUPANTS <br />ONE EXIT - MAX <br />OCCUPANT LOAD PER <br />OCCUPANCY <br />MIN. NO. OF <br />EXITS <br />MINIMUM EXITING DOOR WIDTH <br />(IN INCHES) <br />PROVIDED EXITING DOOR WIDTH (IN <br />INCHES) <br />201 (E) HALLWAY 1,302 SF B Offices 150 8.7 49 1 1.7 36 <br />202 (E) OFFICE 351 SF B Offices 150 2.3 49 1 0.5 60 <br />203 (E) OFFICE 302 SF B Offices 150 2.0 49 1 0.4 36 <br />204 (E) OFFICE 492 SF B Offices 150 3.3 49 1 0.7 72 <br />205 (E) OFFICE 375 SF B Offices 150 2.5 49 1 0.5 36 <br />206 (E) OFFICE 196 SF B Offices 150 1.3 49 1 0.3 36 <br />207 (E) STOR. 91 SF S2 Storage and Stock Rooms 500 0.2 49 1 0.0 36 <br />3,109 SF 20.3 <br />Circulation Serving A (Net) <br />Circulation Serving B (Gross) <br />19,850 SF <br />3,688 SF <br />1 <br />1 <br />2 <br />2 + BF <br />1/8" = 1'-0"1FIRST FLOOR CODE ANALYSIS PLAN <br />2909 S Daimler St <br />4/16/2025