Laserfiche WebLink
UP UP <br />WH <br />UP <br />UP <br />UP <br />FD <br />FD <br />PROJECT <br />NORTH <br />TRUE <br />NORTH <br />(E) STAIR <br />1 98765423 <br />A <br />B <br />C <br />ADJACENT TENANT (NOT IN SCOPE) <br />(E) 3-HOUR FIRE WALL(E) 3-HOUR FIRE WALL <br />47 <br />' <br /> <br />- <br /> <br />8 <br />" <br /> <br />- <br /> <br />V <br />. <br />I <br />. <br />F <br />. <br />NOTES: <br />• SEE SITE PLAN FOR ASSUMED PROPERTY LINE INFORMATION <br />• EXISTING EXTERIOR WALLS ARE 8" THICK CONCRETE TILT-UP, WHICH HAVE A FIRE-RESISTANCE RATING OF 4 HOURS PER CBC TABLE 721(2) <br />• FIRE WALL SHALL EXTEND 18" PAST EXTERIOR SURFACE OF EXTERIOR WALL PER CBC 706.5 (EAST SIDE) <br />• FIRE WALL PERMITTED TO TERMINATE AT INTERIOR SURFACE OF EXTERIOR WALL (WEST SIDE), PROVIDED EXTERIOR WALL HAS A 1-HOUR MIN. FIRE- <br />RESISTANCE RATING FOR A HORIZONTAL DISTANCE OF NOT LESS THAN 4 FEET, WITH NO OPENINGS -PER CBC 706.5 EXCEPTION 1 <br />• FIRE-RESISTANCE RATING OF ADJACENT EXTERIOR WALLS IS 1-HOUR MIN.; WITH NO OPENINGS, FOR A MINIMUM OF 4 FEET FROM THE INTERSECTION <br />OF THE FIRE WALL TO EXTERIOR WALL (AS REQUIRED BY CBC 706.5.1 #1) <br />EXISTING AREA TO REMAIN <br />(E) <br />OFFICE <br />109 <br />(E) <br />NURSERY <br />107 <br />(E) VOID <br />108 <br />(E) <br />MEETING <br />ROOM <br />106 <br />(E) <br />MEETING <br />ROOM <br />105 <br />(E) I.T. <br />ROOM <br />110 <br />(E) <br />MEETING <br />ROOM <br />111 <br />(E) <br />MEETING <br />ROOM <br />112 <br />(E) <br />LUNCH <br />ROOM <br />113 <br />(E) <br />MEETING <br />ROOM <br />104 <br />(E) F.R. <br />104A <br />(E) <br />MEETING <br />ROOM <br />103 <br />(E) <br />HALLWAY <br />102 <br />(E) <br />LOBBY <br />118 <br />(E) <br />MEETING <br />ROOM <br />114 <br />(E) JAN <br />115 <br />(E) MEN <br />116 <br />(E) <br />WOMEN <br />117 <br />(E) <br />AUDITORIUM <br />119 <br />(E) <br />STORAGE <br />120 <br />(E) <br />STORAGE <br />121 <br />YOUTH <br />ROOM <br />123 <br />DOOR <br />3' - 0"6" <br />24' - 7 1/2" - V.I.F. <br />ALIGN (E) <br />ELECT. <br />124 <br />36' - 2"24' - 8"24' - 0"24' - 0"24' - 0"24' - 0"24' - 0"20' - 3" <br />201' - 1" (EXISTING OVERALL BUILDING) <br />50 <br />' <br /> <br />- <br /> <br />3 <br />" <br />50 <br />' <br /> <br />- <br /> <br />3 <br />" <br />10 <br />0 <br />' <br /> <br />- <br /> <br />6 <br />" <br /> <br />( <br />E <br />X <br />I <br />S <br />T <br />I <br />N <br />G <br /> <br />O <br />V <br />E <br />R <br />A <br />L <br />L <br /> <br />B <br />U <br />I <br />L <br />D <br />I <br />N <br />G <br />) <br />2 <br />A5.1 <br />5.01 <br />8.01 <br />9.01 <br />9.02 <br />1 <br />A5.1 <br />(E) <br />LOBBY <br />101 <br />2.07 <br />2.07 <br />EXISTING CONSTRUCTION SHALL REMAIN <br />LEGEND <br />PROPOSED CONSTRUCTION; <br />INTERIOR NON-LOAD-BEARING, FULL-HEIGHT M. STEVEN <br />CAMP <br />C-18,407 <br />JUN. 30, 2025 <br />RENEWAL DATESTATEOFCALIFORNIA <br />LICENSED A RCHITECTM. STEVEN <br />CAMP <br />C-18,407 <br />JUN. 30, 2025 <br />RENEWAL DATESTATEOFCALIFORNIA <br />LICENSED A RCHITECT <br />PROJECT ARCHITECT: <br />PROJECT MANAGER: <br />DRAWN BY: <br />PROJECT NUMBER: <br />All ideas, designs and plans indicated or represented <br />by these drawings are owned by and are the property <br />of Elements Architecture, Inc. and were created and <br />developed for use in connection with the specified <br />project. None of such ideas, designs, or plans shall <br />be used for any purpose whatsoever without the <br />written permission of Elements Architecture. <br />Elements Architecture, Inc. <br />PROJECT NAME: <br />NO.DESCRIPTION DATE <br />M. Steven Camp, AIA <br />Scott Holland, AIA <br />PROJECT ADDRESS: <br />SHELLEY MACDONALD <br />EA <br />SHELLEY MACDONALD <br />1/ <br />9 <br />/ <br />2 <br />0 <br />2 <br />5 <br /> <br />8 <br />: <br />2 <br />2 <br />: <br />3 <br />6 <br /> <br />A <br />M <br />21.105 <br />TENANT <br />IMPROVEMENT <br />(YOUTH ROOM) <br />2909 DAIMLER STREET <br />SANTA ANA, CA 92705 <br />A2.1 <br />PROPOSED GROUND <br />FLOOR PLAN <br />COMPASS BIBLE CHURCH, <br />TUSTIN SANTA ANA <br />ARCHITECTURAL KEYNOTES <br />## DESCRIPTION <br />2.07 EXISTING EXIT DOOR WITH PANIC HARDWARE - V.I.F. <br />5.01 NEW INTERIOR NON-LOAD-BEARING FULL-HEIGHT PARTITION: 6" 25 GA. MTL STUDS AT <br />16" O.C. MAX WITH ACOUSTIC BATT INSULATION FULL DEPTH OF STUD & 5/8" GYP. BD. <br />BOTH SIDES <br />8.01 NEW INTERIOR 3'-0" W X 8'-0" H DOOR & FRAME: 1 3/4" SCW WOOD WITH WOOD VNR <br />FINISH & PAINTED H.M. FRAME TO MATCH EXISTING ADJACENT DOORS. <br />9.01 ADJUST EXISTING FLOOR FINISH AT NEW PARTITION AS REQUIRED; PROVIDE NEW <br />WALL BASE AT BOTH SIDES OF WALL TO MATCH EXISTING ADJACENT (MANUF: BURKE, <br />PRODUCT: RUBBER MYTE TP, COLOR: ROCKY 660, HEIGHT: 2.5" - VERIFY) <br />9.02 PROVIDE NEW PAINTED FINISH AT BOTH SIDES OF NEW PARTITION TO MATCH <br />EXISTING ADJACENT (MANUF: SHERWIN WILLIAMS, COLOR: SW7022 ALPACA - VERIFY) <br />1/8" = 1'-0"1PROPOSED FIRST FLOOR PLAN <br />2909 S Daimler St <br />4/16/2025