(OPEN CEILING)
<br />1 98765423
<br />A
<br />B
<br />C
<br />PROJECT
<br />NORTH
<br />TRUE
<br />NORTH
<br />10
<br />0
<br />'
<br />
<br />-
<br />
<br />6
<br />"
<br />
<br />(
<br />E
<br />X
<br />I
<br />S
<br />T
<br />I
<br />N
<br />G
<br />
<br />O
<br />V
<br />E
<br />R
<br />A
<br />L
<br />L
<br />
<br />B
<br />U
<br />I
<br />L
<br />D
<br />I
<br />N
<br />G
<br />)
<br />201' - 1" (EXISTING OVERALL BUILDING)
<br />36' - 2 5/16" 24' - 7 11/16" 24' - 0" 24' - 0" 24' - 0" 24' - 0" 24' - 0" 19' - 7"8"
<br />ADJACENT TENANT (NOT IN SCOPE)
<br />50
<br />'
<br />
<br />-
<br />
<br />3
<br />"
<br />50
<br />'
<br />
<br />-
<br />
<br />3
<br />"
<br />(OPEN CEILING)
<br />(OPEN CEILING)
<br />(OPEN CEILING)
<br />EQ
<br />20
<br />'
<br />
<br />-
<br />
<br />0
<br />"
<br />EQ
<br />EQ 16' - 0"EQ
<br />D D
<br />DD (R)
<br />2
<br />A5.1
<br />(R)
<br />26.01
<br />26.02
<br />2.04
<br />23.01
<br />23.02
<br />2.05
<br />2.05
<br />YOUTH
<br />ROOM
<br />123
<br />(E)
<br />STORAGE
<br />121
<br />(E)
<br />AUDITORIUM
<br />119
<br />(E)
<br />LOBBY
<br />118
<br />(E)
<br />STORAGE
<br />120
<br />(E)
<br />HALLWAY
<br />102
<br />(E)
<br />OFFICE
<br />109
<br />(E)
<br />NURSERY
<br />107
<br />(E) I.T.
<br />ROOM
<br />110
<br />(E)
<br />MEETING
<br />ROOM
<br />106
<br />(E)
<br />MEETING
<br />ROOM
<br />105
<br />(E)
<br />MEETING
<br />ROOM
<br />111
<br />(E)
<br />MEETING
<br />ROOM
<br />112
<br />(E)
<br />LUNCH
<br />ROOM
<br />113
<br />(E)
<br />MEETING
<br />ROOM
<br />103
<br />(E)
<br />MEETING
<br />ROOM
<br />104
<br />(E) MEN
<br />116
<br />(E)
<br />WOMEN
<br />117
<br />(E)
<br />MEETING
<br />ROOM
<br />114
<br />EXISTING AREA TO REMAIN
<br />CEILING & LIGHTING LEGEND
<br />EXISTING
<br />ILLUMINATED EMERGENCY SIGN -
<br />CEILING / WALL MOUNTED
<br />PROPOSED
<br />SUSPENDED PENDANT LIGHT FIXTURE -B.O.
<br />FIXTURE = 14'-0" A.F.F.*D
<br />1. MEANS OF EGRESS LIGHTING SHALL BE PROVIDED W/ AN
<br />ILLUMINATION LEVEL OF NOT LESS THAN 1 FOOT-CANDLE @ THE
<br />WALKING SURFACE. (C.B.C. §1008.2)
<br />2. WHERE BUILDINGS, ROOMS, OR SPACES REQUIRE TWO OR MORE
<br />MEANS OF EGRESS AN EMERGENCY POWER BACKUP SUPPLY SHALL
<br />BE PROVIDED FOR A DURATION OF NOT LESS THAN 90 MIN. (C.B.C. §
<br />1008.3 THRU §1008.3.4)
<br />3. VERIFY ALL EXISTING CONDITIONS IN FIELD UPON DEMOLITION &
<br />NOTIFY ARCHITECT IMMEDIATELY OF ANY DISCREPANCIES RELATED
<br />TO CEILINGS, STRUCTURE, LIGHTING, OR MECHANICAL
<br />INFORMATION.
<br />4. DUCTWORK, CONDUIT, PIPE, WIRE, ETC. SHALL BE HIDDEN FROM
<br />VIEW & CONCEALED W/IN WALL FRAMING, FLOOR FRAMING,
<br />SOFFITS, CHASES, & CEILING PLENUM SPACES WHENEVER
<br />POSSIBLE. IF VISIBLE, DUCTWORK, CONDUIT, PIPE, WIRE, ETC.
<br />SHALL BE INSTALLED IN A NEAT & ORDERLY MANNER. EXT. FINISH
<br />SHALL BE MODIFIED (I.E. PAINT) TO MATCH NEAREST ADJACENT
<br />SURFACE.
<br />5. EXIT SIGNS SHALL BE INTERNALLY OR EXTERNALLY ILLUMINATED.
<br />(C.B.C. §1013.3)
<br />6. ELECTRICALLY POWERED EXIT SIGNS SHALL BE LISTED & LABELED
<br />IN ACCORDANCE W/ UL 924. (C.B.C. §1013.5)
<br />7. EMERGENCY POWER SUPPLY TO ILLUMINATE EXIT SIGNS FOR A
<br />DURATION OF NOT LESS THAN 90 MIN.
<br />8. IN EVENT OF POWER SUPPLY FAILURE, AN EMERGENCY ELECTRICAL
<br />SYSTEM SHALL AUTOMATICALLY ILLUMINATE AISLES, LOBBY,
<br />CORRIDOR, & EXT. DOOR LANDING. EMERGENCY POWER SYSTEM
<br />SHALL PROVIDE POWER FOR A DURATION OF NOT LESS THAN 90
<br />MIN. & SHALL CONSIST OF STORAGE BATTERIES, UNIT EQUIPMENT
<br />OR AN ON-SITE GENERATOR. INITIAL ILLUMINATION AVERAGE OF 1
<br />FOOT-CANDLE & MIN. 0.1 FOOT-CANDLE @ FLOOR LEVEL. (C.B.C.
<br />1008.3.4.)
<br />9. IT IS THE CONTRACTOR'S RESPONSIBILITY TO COORDINATE
<br />INSTALLATION OF ALL TRADES, INCLUDING DUCTWORK, CONDUIT,
<br />UTILITY LINES, AND FIXTURES. AT EXPOSED/OPEN CEILINGS,
<br />DUCTWORK SHALL BE MOUNTED ABOVE LIGHT FIXTURES AS HIGH
<br />AS POSSIBLE -CONTRACTOR SHALL NOTIFY ARCHITECT
<br />IMMEDIATELY OF ANY DISCREPANCIES AS TO MOUNTING HEIGHTS
<br />OF ALL EXPOSED COMPONENTS, OR ANY EXISTING UNFORESEEN
<br />CONDITIONS PREVENTING COMPLIANCE WITH MOUNTING HEIGHTS
<br />PER PLANS
<br />10. ALL EXPOSED ELEMENTS SHALL BE PAINTED TO MATCH ADJACENT
<br />SURFACE UNLESS NOTED OTHERWISE. ALL EXPOSED REGISTERS
<br />SHALL HAVE FINISH TO MATCH ADJACENT SURFACE.
<br />NOTES
<br />RELOCATED SUSPENDED PENDANT LIGHT FIXTURE -
<br />B.O. FIXTURE = 14'-0" A.F.F.*D (R)
<br />*VERIFY FINAL EXISTING RELOCATED / NEW
<br />PENDANT LOCATIONS WITH EMERGENCY BACKUP
<br />REQUIREMENTS -SEE ELECT.
<br />M. STEVEN
<br />CAMP
<br />C-18,407
<br />JUN. 30, 2025
<br />RENEWAL DATESTATEOFCALIFORNIA
<br />LICENSED A RCHITECTM. STEVEN
<br />CAMP
<br />C-18,407
<br />JUN. 30, 2025
<br />RENEWAL DATESTATEOFCALIFORNIA
<br />LICENSED A RCHITECT
<br />PROJECT ARCHITECT:
<br />PROJECT MANAGER:
<br />DRAWN BY:
<br />PROJECT NUMBER:
<br />All ideas, designs and plans indicated or represented
<br />by these drawings are owned by and are the property
<br />of Elements Architecture, Inc. and were created and
<br />developed for use in connection with the specified
<br />project. None of such ideas, designs, or plans shall
<br />be used for any purpose whatsoever without the
<br />written permission of Elements Architecture.
<br />Elements Architecture, Inc.
<br />PROJECT NAME:
<br />NO.DESCRIPTION DATE
<br />M. Steven Camp, AIA
<br />Scott Holland, AIA
<br />PROJECT ADDRESS:
<br />SHELLEY MACDONALD
<br />EA
<br />SHELLEY MACDONALD
<br />1/
<br />9
<br />/
<br />2
<br />0
<br />2
<br />5
<br />
<br />8
<br />:
<br />2
<br />3
<br />:
<br />0
<br />1
<br />
<br />A
<br />M
<br />21.105
<br />TENANT
<br />IMPROVEMENT
<br />(YOUTH ROOM)
<br />2909 DAIMLER STREET
<br />SANTA ANA, CA 92705
<br />A4.1
<br />PROPOSED GROUND
<br />FLOOR REFLECTED
<br />CEILING PLAN
<br />COMPASS BIBLE CHURCH,
<br />TUSTIN SANTA ANA
<br />ARCHITECTURAL KEYNOTES
<br />## DESCRIPTION
<br />2.04 EXISTING OPEN CEILING WITH SCRIM SHEET O/ R-30 BATT INSULATION, TYP. - MODIFY,
<br />RE-ATTACH INSULATION AND REPLACE SCRIM SHEET AT NEW PARTITION LOCATION AS RQ'D
<br />2.05 EXISTING EXIT SIGNAGE TO REMAIN - SEE ELECTRICAL FOR ALL REQUIREMENTS, VERIFY IN
<br />FIELD
<br />23.01 NEW DUCT WITH SIDE REGISTERS PER MECHANICAL - MOUNT AS HIGH AS POSSIBLE AT
<br />OPEN CEILING
<br />23.02 NEW WALL-MOUNTED TRANSFER GRILLE PER MECHANICAL - INSTALL SOUND BOOT AND
<br />PROVIDE ACOUSTICAL CAULKING AT ALL PENETRATIONS. PAINT DEVICE IN COMPLETE TO
<br />MATCH ADJ. WALL FINISH
<br />26.01 EXISTING RELOCATED SUSPENDED PENDANT LIGHT FIXTURE, TYP. OF (2)
<br />26.02 NEW SUSPENDED PENDANT LIGHT FIXTURE, TYP. OF (2)
<br />1/8" = 1'-0"1FIRST FLOOR REFLECTED CEILING PLAN
<br />2909 S Daimler St
<br />4/16/2025
|