Laserfiche WebLink
N <br />(N) SOLAR PANELS AND <br />MICRO-INVERTERS ON ROOF <br />SHEET <br />CONTRACTOR <br />ILUM SOLAR <br /> 300 CARRIAGE DR A, <br /> SANTA ANA, <br /> CA 92707 <br /> APN:93317027 <br /> DATE:5/18/2024 <br />RAMIREZ <br />RESIDENCE <br />License#:1092865, <br />C-46 & C-10 <br />ADDRESS: <br />4135 NORTHGATE BLVD <br />SUITE 9, SACRAMENTO, <br />CA 95834, USA <br />DESIGNER: OVB <br />E-3 <br />SOVEREIGN WY <br /> LOCATION OF COMBINER BOX. <br />1.NOT ALL PLACARDS SHOWN MAY BE REQUIRED BY LOCAL AHJ. CONTRACTOR TO VERIFY PLACARD <br />REQUIREMENTS WITH LOCAL AHJ BEFORE INSTALLATION. <br />2.ALL PLAQUES AND SIGNAGE REQUIRED BY THE LATEST EDITION OF THE CALIFORNIA ELECTRICAL CODE <br />3.ALTERNATE POWER SOURCE PLACARD SHALL BE METALLIC OR PLASTIC, ENGRAVED OR MACHINE <br />PRINTED LETTERS IN A CONTRASTING COLOR TO THE PLAQUE. THIS PLAQUE WILL BE ATTCHED BY POP <br />RIVETS OR SCREWS OR OTHER APPROVED METHOD. <br />4.DIRECTORY PLACARD MARKING CONTENT AND FORMAT: RED BACKGROUND, WHITE LETTERING, <br />MINIMUM 3/8" LETTER HIEGHT, ALL CAPITAL LETTERS, ARIAL OR SIMILAR FONT, NON BOLD, REFLECTIVE <br />WEATHER RESISTANT MATERIAL SUITABLE FOR THE ENVIRONMENT. <br />PERMANENT SIGNAGE NOTES: <br />WARNING! <br />DO NOT RELOCATE THIS <br />OVERCURRENT DEVICE <br />POWER SOURCE OUTPUT CONNECTION <br />LABEL LOCATION: <br />ADJACENT TO PV BREAKER (IF APPLICABLE). <br />PER CODE(S): CEC 2022: 705.12(B)(3)(2) <br />! <br />DO NOT ADD LOADS <br />PHOTOVOLTAIC SYSTEM <br />COMBINER PANEL <br />WARNING <br />LABEL LOCATION: <br />PHOTOVOLTAIC AC COMBINER (IF <br />APPLICABLE). <br />PER CODE(S): CEC 2022: 705.12(B)(3)(3) <br />SOLAR PV SYSTEM EQUIPPED <br />WITH RAPID SHUTDOWN <br />SOLAR ELECTRIC <br />PV PANELS <br />TURN RAPID SHUTDOWN <br />SWITCH TO THE "OFF" <br />POSITION TO SHUT DOWN <br />PV SYSTEM AND REDUCE <br />SHOCK HAZARD IN THE <br />ARRAY. <br />LABEL LOCATION: <br />ON OR NO MORE THAT 3 M (10 FT) FROM THE SERVICE <br />DISCONNECTING MEANS TO WHICH THE PV SYSTEMS <br />ARE CONNECTED. <br />ELECTRICAL SHOCK HAZARD <br />WARNING! <br />LABEL LOCATION: <br />INVERTER(S), AC DISCONNECT(S), AC <br />COMBINER PANEL (IF APPLICABLE). <br />PER CODE(S): CEC 2022: 705.15(C)(4)& <br />690.13(B) <br />TERMINALS ON LINE AND LOAD <br />SIDES MAY BE ENERGIZED IN <br />THE OPEN POSITION <br />RAPID SHUTDOWN SWITCH <br />FOR SOLAR PV SYSTEM <br />LABEL LOCATION: <br />UTILITY SERVICE ENTRANCE/METER, INVERTER/DC <br />DISCONNECT IF REQUIRED BY LOCAL AHJ, OR <br />OTHER LOCATIONS AS REQUIRED BY LOCAL AHJ. <br />PER CODE(S): CEC 2022:690.56(C)(2), <br />CFC 2022: 1204.5.3 <br />MAXIMUM AC OPERATING CURRENT: <br />NOMINAL OPERATING AC VOLTAGE: <br /> 12.10 AMPS <br />240.0 VAC <br />PHOTOVOLTAIC AC DISCONNECT <br />LABEL LOCATION: <br />AC DISCONNECT(S), PHOTOVOLTAIC SYSTEM POINT OF <br />INTERCONNECTION. <br />PER CODE(S): CEC 2022: 690.54 <br />CAUTION <br />TRI POWER SOURCES <br />SECOND SOURCE IS PV SYSTEM <br />THIRD SOURCE IS AC BATTERY <br />! <br />LABEL LOCATION : BATTERY <br />F.D. – ELECTRICAL <br />BLDG DISCONNECT <br /># 2 of 2 <br /># 2 <br />F.D. – ELECTRICAL <br />BLDG DISCONNECT <br /># 1 of 2 <br /># 1 <br />300 CARRIAGE DR A <br />MULTIPLE SOURCES OF POWER <br />WITH DISCONNECTS AS SHOWN <br />CAUTION: <br />PV INTERCONNECTION POINT. LOCATION OF METER MAIN COMBO. <br /> LOCATION OF PV DISCONNECT. <br /> LOCATION OF (1) ENPHASE IQ BATTERY 5P. <br /> LOCATION OF ESS DISCONNECT. <br />300 W Carriage Dr Unit# <br />A - 201826746/12/2024