SCOPE OF WORK: <br />INSTALL (20) Q.CELLS Q.PEAK DUO BLK ML-G10+ 405 SOLAR ELECTRIC MODULES AND <br />(20) SOLAREDGE S440 DC POWER OPTIMIZERS ON THE EXISTING 1ST STORY COMPOSITION <br />ROOF. INSTALL ASSOCIATED MOUNTING HARDWARE, JUNCTION BOXES, CONDUIT, <br />CONDUCTORS AND GROUNDING. INSTALL (1) SOLAREDGE ENERGY HUB SE7600H-US <br />INVERTER WITH INTEGRATED DC DISCONNECT, (1) SOLAREDGE ENERGYBANK <br />BAT-10K1PSOB-01 BATTERY, (1) AC DISCONNECT, AND INSTALL OCPD IN MAIN SERVICE PANEL. <br />HOMEOWNER: TYNA YAM <br />PH: 714.542.0788 <br />ADDRESS: 3002 W. CUBBON STREET <br />SANTA ANA, CA 92705 <br />DATE: 10/12/23 <br />ING ELECTRIC INC <br />1451 DOMIGUEZ RANCH ROAD <br />CORONA, CA 92882 <br />PH: 951.399.2555 <br />NORAN ING C10 - 1048140 <br />NOTE: <br />DIMENSIONS AND FEATURES SHOWN ARE CLOSE TO <br />SCALE BUT WERE TAKEN FROM A FIELD SURVEY AND <br />APPROXIMATIONS MADE USING GOOGLE EARTH. <br />PROPERTY <br />LINE <br />(E) 200 AMP MAIN <br />SERVICE PANEL <br />W. C <br />U <br />B <br />B <br />O <br />N <br /> <br />S <br />T <br />R <br />E <br />E <br />T <br />N <br />SCALE: 1/16"=1' <br />8 16 32 48 <br />VENT (TYP) <br />(N) AC DISCONNECT & <br />(N) INVERTER/ <br />DC DISCONNECT <br />SITE/ROOF PLAN <br />ARRAY #1: (20) MODULES <br />TILT = 18°, AZ = 220° <br />1 <br />2 <br />3 <br />4 <br />5 6 <br />16 <br />SHEET <br />NOTICE: <br />ANY CHANGES TO OR USES OF THESE DOCUMENTS/DRAWINGS WITHOUT THE <br />WRITTEN CONSENT OF JENNIFER KEMME OR SCOTT HARRIS ARE STRICTLY PROHIBITED. <br />2 OF 5 <br />PLANS PREPARED BY: <br />JENNIFER KEMME <br />PH: 909.748.1300 <br />EXISTING 1-STORY ROOF: <br />ASPHALT SHINGLE, <br />FELT & 1 2" SHEATHING <br />OVER RAFTERS <br />EXISTING 2 X 4 <br />RAFTERS @ 24" OC <br />MODULES: <br />74.0" X 41.1" <br />48.5 LBS EACH <br />K2 CROSSRAIL 48X RAIL MOUNTING <br />SYSTEM WITH K2 EVERFLASH <br />ECOMP KIT ROOF ATTACHMENTS <br />(USE 5 16" STAINLESS STEEL LAG <br />BOLTS @ 72" OC OR LESS WITH A <br />MINIMUM EMBEDMENT OF 21 2" <br />INTO ROOF RAFTERS), <br />WATERPROOF ALL CONNECTION <br />LOCATIONS PER MANUFACTURER'S <br />INSTRUCTIONS <br />3" MIN. <br />8" MAX. <br />NTS <br />ELEVATION DETAIL <br />1.5' FIRE CLEARANCE <br />99499PV <br />(N) BATTERY <br />ROOF ACCESS POINTS ARE AT THE <br />STRUCTURALLY STRONG PART OF <br />THE BUILDING AND DO NOT REQUIRE <br />LADDERING OVER OPENINGS. <br />* <br />TOTAL ROOF AREA = 2773 SF <br />TOTAL SOLAR AREA = 425 SF <br />425 SF/2773 SF = 0.15 <br />ARRAYS COVER 15% OF TOTAL ROOF AREA <br />13 <br />8 <br />9 <br />10 <br />11 <br />12 <br />14 <br />18 17 <br />15 <br />19 <br />20 <br />7 <br />S. M <br />O <br />H <br />A <br />W <br />K <br /> <br />D <br />R <br />I <br />V <br />E <br />W. M <br />C <br />F <br />A <br />D <br />D <br />E <br />N <br /> <br />A <br />V <br />E <br />N <br />U <br />E <br />3' <br />SCALE: 1 4" = 1'-0" <br />WALL ELEVATION <br />(E) 200 AMP MAIN <br />SERVICE PANEL (N) INVERTER/ <br />DC DISCONNECT <br />(N) BATTERY <br />(E) WINDOWS <br />FLOOR <br />LEVEL <br />4" <br />(N) AC DISCONNECT <br />(E) CORNER <br />(E) WINDOW <br />7' <br />2'17'-8" <br />7'-8" <br />9'-4" <br />* <br />* <br />(E) COVERED PATIO <br />3002 W Cubbon St - <br />2018128112/6/2023