Laserfiche WebLink
RAFTER <br />IRON RIDGE TILT <br />LEG <br />SOLAR PANEL <br />END CLAMP <br />IRON RIDGE RAIL <br />TILT LEGS <br />FLAT ROOF <br />ANGLE 10° <br />END CLAMP <br />1/4" BOLT <br />XR100 RAIL <br />3/8" Flange nut <br />STANDOFFS <br />U-FOOT <br />IRONRIDGE <br />ADJUSTABLES <br />The 1/4” x 3.5" lag bolt <br />for the ATTACHMENT <br />base to the rafter. <br />FLUSH MOUNT <br />IRONRIDGE <br />TILT LEGS <br />JB <br />OPTMI OPTMI OPTMI OPTMI OPTMI <br />OP <br />T <br />MI <br />OPTMIOPTMIOPTMIOPTMI <br />OPTMI OPTMI OPTMI OPTMI OPTMI <br />OPTMI <br />1.A.1 (10) <br />1.A.2 (6) <br />RAPID SHUTDOWN CONTROLLER <br />MI <br />RAPID SHUTDOWN BOX <br />MICRO INVERTER <br />COMBINER BOX <br />AC DISCONNECT SWITCH <br />MAIN SERVICE PANEL BOARD <br />INVERTER "A" <br />MID CLAMP <br />SOLAR MOUNT SYSTEM <br />COUNDUIT (POS/NEG/GRND) <br />RAILING OR SLIDER <br />OPT OPTIMIZER <br />& "B" <br />SP SUB-PANEL <br />JUCTION BOX <br />LINE WALL <br />B BATTERY <br />T AUTO-TRANSFORMER <br />AC AC LOAD CENTER <br />LEGEND <br />END CLAMP <br />As Noted <br />MI <br />N <br />C <br />H <br />A <br />C <br />A <br />, <br /> <br />J <br />O <br />S <br />E <br /> <br />L <br />U <br />I <br />S <br />SA <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />7 <br />- <br />1 <br />8 <br />3 <br />0 <br />AP <br />N <br />: <br /> <br />4 <br />0 <br />3 <br />- <br />1 <br />9 <br />3 <br />- <br />1 <br />6 <br />RE <br />S <br />I <br />D <br />E <br />N <br />T <br />I <br />A <br />L <br /> <br />P <br />H <br />O <br />T <br />O <br />V <br />O <br />L <br />T <br />A <br />I <br />C <br />31 <br />5 <br /> <br />E <br /> <br />S <br />T <br />A <br />N <br />F <br />O <br />R <br />D <br /> <br />S <br />T <br />R <br />E <br />E <br />T <br />FULL SIZE PRINT: 17"x11" <br />A <br />REV <br />Signature <br />DRAWINGS PROVIDED BY: <br />SOLAR MAX DESIGN <br />Email: solarmax.dsgn@gmail.com <br />Web: www.solarmaxdsgn.com <br />Phone:(310) 740-9649(310) 844-7370 & <br />3805 E 2ND STREET, SUITE C <br />LONG BEACH, CA 90803 <br />CLIENT INFORMATION: <br />PROJECT: <br />The contractor shall provide a written letter <br />to the building inspector stating that all <br />inaccessible structural connections have <br />been installed in conformance with the <br />requirements of the approved plans. <br />NOTE: <br />DESCRIPTION DATE: <br />B <br />DATE: <br />SCALE: <br />SHEET TITLE: <br />SHEET <br />NUMBER: <br />4/7/2023 <br />Class: C10 <br />Solar Life <br />7129 Westport Street <br />Riverside, California 92506 <br />Phone: (626) 353-2838 <br />License: 1073930 <br />CONTRACTOR <br />Signature <br />Exp: 03/31/2023 <br />ARRAY <br />LAYOUT <br />ARRAY LAYOUT PV-3 <br />STRING LEGEND <br />1. A. 2 (11) <br />STRING LENGTH <br />STRING ID # <br />MPPT (A,B OR C) <br />INVERTER ID # <br />18 <br />" <br /> <br />M <br />A <br />X <br />12 <br />" <br />ATTACHMENT <br />POINT, TYPICAL <br />--- <br />1 <br />SCALE: 1/8" = 1'-0" <br />48" MAX <br />MOUNT SPACING <br />DETAIL A <br />SCALE: NONE <br />MOUNTING DETAIL <br />SCALE: NONE <br />MANUFACTURER: <br />MODEL: <br />MODULE WEIGHT: <br />MODULE LENGTH: <br />MODULE WIDTH: <br />MODULE AREA: <br />ROOF SPECIFICATIONS <br />ROOF TYPE: <br />RAFTER SIZE: <br />MAX. RAFTER SPACING: <br />ROOFING MATERIAL: <br />SLOPE OF ROOF: <br />ARRAY SPECIFICATIONS <br />TOTAL MODULES: <br />MODULE WEIGHT: <br />RACKING WEIGHT: <br />TOTAL WEIGHT: <br />ARRAY AREA: <br />ARRAY DEAD LOAD: <br />RAIL MAX. SPAN: <br />NUMBER OF MOUNTS: <br />TRUSS <br />2x6 <br />@ 24" O.C. <br />TORCH DOWN BITUMEN <br />FLAT ROOF 2% SLOPE <br />16 <br />48.50 LBS <br />172.27 LBS <br />948.27 LBS <br />337.93 SF <br />2.8 LBS/SF <br />48" MAX. <br />36 <br />HANWHA Q CELLS <br />Q.PEAK DUO BLK ML-G10 400 <br />48.50 LBS <br />74.00 IN <br />74.00 IN <br />21.12 SF <br />MODULE SPECIFICATIONS <br />SPECIFICATIONS <br />SQ. FT. ROOF:899 SQ.FT. SQ.FT. <br />% OF ARRAY COVERAGE: 38% <br />RACKING INFORMATION: <br />MOUNTING: <br />RAILING: <br />FLAT ROOF SYSTEM <br />XR-10 <br />MANUFACTURER:IRONRIDGE <br />NEW SOLAR MODULES <br />ARRAY SUPPORT <br />RAIL, TYPICAL <br />ATTACHMENT <br />POINT, TYPICAL--- <br />1 <br />2"X6" @ 24" O.C. <br />3' <br />- <br />0 <br />" <br />6' <br />- <br />2 <br />" <br />6' <br />- <br />2 <br />" <br />1' <br />- <br />6 <br />" <br />6' <br />- <br />2 <br />" <br />4' <br />- <br />6 <br />" <br />1' <br />- <br />6 <br />" <br />3'-0"17'-4"4'-8" <br />3'-0"10'-4"1'-9"6'-11"3'-6" <br />15 <br />" <br />44 <br />" <br />15 <br />" <br />15 <br />" <br />44 <br />" <br />15 <br />" <br />15 <br />" <br />44 <br />" <br />15 <br />" <br />9" <br />23 <br />" <br />9" <br />3'-0" <br />315 E Stanford St - <br />201817961/30/2024