Laserfiche WebLink
JB <br />OPTMI OPTMI OPTMI OPTMI OPTMI <br />OP <br />TMI <br />OPTMIOPTMIOPTMIOPTMI <br />OPTMI OPTMI OPTMI OPTMI OPTMI <br />OPTMI <br />1.A.1 (10) <br />1.A.2 (6) <br />As Noted <br />MI <br />N <br />C <br />H <br />A <br />C <br />A <br />, <br /> <br />J <br />O <br />S <br />E <br /> <br />L <br />U <br />I <br />S <br />SA <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />7 <br />- <br />1 <br />8 <br />3 <br />0 <br />AP <br />N <br />: <br /> <br />4 <br />0 <br />3 <br />- <br />1 <br />9 <br />3 <br />- <br />1 <br />6 <br />RE <br />S <br />I <br />D <br />E <br />N <br />T <br />I <br />A <br />L <br /> <br />P <br />H <br />O <br />T <br />O <br />V <br />O <br />L <br />T <br />A <br />I <br />C <br />31 <br />5 <br /> <br />E <br /> <br />S <br />T <br />A <br />N <br />F <br />O <br />R <br />D <br /> <br />S <br />T <br />R <br />E <br />E <br />T <br />FULL SIZE PRINT: 17"x11" <br />A <br />REV <br />Signature <br />DRAWINGS PROVIDED BY: <br />SOLAR MAX DESIGN <br />Email: solarmax.dsgn@gmail.com <br />Web: www.solarmaxdsgn.com <br />Phone:(310) 740-9649(310) 844-7370 & <br />3805 E 2ND STREET, SUITE C <br />LONG BEACH, CA 90803 <br />CLIENT INFORMATION: <br />PROJECT: <br />The contractor shall provide a written letter <br />to the building inspector stating that all <br />inaccessible structural connections have <br />been installed in conformance with the <br />requirements of the approved plans. <br />NOTE: <br />DESCRIPTION DATE: <br />B <br />DATE: <br />SCALE: <br />SHEET TITLE: <br />SHEET <br />NUMBER: <br />4/7/2023 <br />Class: C10 <br />Solar Life <br />7129 Westport Street <br />Riverside, California 92506 <br />Phone: (626) 353-2838 <br />License: 1073930 <br />CONTRACTOR <br />Signature <br />Exp: 03/31/2023 <br />SITE PLAN <br />SITE PLAN <br />SCALE: 1" = 20'-0" <br />PV-2 <br />E STANFORD STREET <br />1. UTILITY HAS 24-HOUR UNRESTRICTED ACCESS TO ALL <br />PHOTOVOLTAIC SYSTEM COMPONENTS LOCATED AT SERVICE <br />ENTRANCE <br />2. WORKSPACE IN FRONT OF AC ELECTRICAL SYSTEM <br />COMPONENT SHALL BE IN ACCORDANCE WITH APS AND NEC <br />REQUIREMENTS FOR APS REQUIREMENTS, REFERENCE <br />SECTION 300 OF THE APS ESRM AND SECTION 8.2 OF THE APS <br />INTERCONNECTION REQUIREMENTS <br />3. REFERENCE SECTION 301.15 OF THE APS ESRM FOR <br />ELECTRICAL METER SEPARATION BETWEEN WATER AND GAS <br />4. NO VENTS (DORMERS, PLUMBING AND MECHANICAL) SHALL <br />BE COVERED OR RELOCATED. "ALL EQUIPMENT SHALL BE <br />PAINTED PRIOR TO INSPECTION." <br />5.ALL EQUIPMENT SHALL BE LISTED AND LABELED BY A <br />NATIONALLY RECOGNIZED TESTING LABORATORY (NRTL) <br />6.SEE SHEET PV-5 FOR ELECTRICAL CONDUIT, WIRE, AND <br />EQUIPMENT DETAILS. <br />NOTES <br />PHOTOVOLTAIC EQUIPMENT: <br />1.MODULES: <br />INSTALLATION TYPE: <br />AZIMUTH: <br />TILT: <br />MOUNTED ON: <br />10° <br />0°, 180° <br />SYSTEM DESCRIPTION <br />OVERALL SYSTEM: <br />DC RATING: <br />CEC RATING: <br />6.400 kW DC <br />5.844 kW AC <br />ROOF <br />PROPERTY DATA: <br />SQ.FT. OF ARRAY: <br />% OF ARRAY COVERAGE: <br />SQ.FT. OF ROOF: <br />NUMBER OF STORIES: <br />SPRINKLERS: <br />ZONING: <br />1 <br />337.93 <br />899 SQ.FT. <br />38% <br />NO <br />R1 <br />RACKING INFORMATION: <br />MOUNTING: <br />RAILING: <br />FLAT ROOF SYSTEM <br />XR-10 <br />MANUFACTURER:IRONRIDGE <br />MANUFACTURER: <br />QTY: <br />HANWHA Q CELLS <br />16 <br />MODEL:Q.PEAK DUO BLK ML-G10 400 <br />2.INVERTER: <br />MANUFACTURER: <br />QTY: <br />ENPHASE <br />16 <br />MODEL:IQ8PLUS-72-2-US <br />JURISDICTION:SANTA ANA <br />CL <br />(E <br />) <br /> <br />D <br />R <br />I <br />V <br />E <br />W <br />A <br />Y <br />(E <br />) <br /> <br />G <br />A <br />R <br />A <br />G <br />E <br />(N) AC DISCONNECT <br />200 AMPS <br />(N) COMBINER BOX <br />(E) MAIN SERVICE PANELBOARD <br />36" FIRE ACCESS PATHWAY <br />FLAT ROOF <br />20 <br />' <br />- <br />0 <br />" <br />38 <br />' <br />- <br />0 <br />" <br />37 <br />' <br />- <br />0 <br />" <br />23 <br />' <br />- <br />0 <br />" <br />30 <br />' <br />- <br />0 <br />" <br />2' <br />- <br />0 <br />" <br />4'-0"44'-0"2'-0" <br />2' <br />- <br />0 <br />" <br />48 <br />' <br />- <br />0 <br />" <br />10 <br />' <br />- <br />0 <br />" <br />30 <br />' <br />- <br />0 <br />" <br />30 <br />' <br />- <br />0 <br />" <br />30 <br />' <br />- <br />0 <br />" <br />11'-0"9'-0"17'-0"13'-0" <br />11'-0"26'-0"10'-0"3'-0" <br />16 <br />' <br />- <br />0 <br />" <br />21 <br />' <br />- <br />0 <br />" <br />2'-0"10'-0"8'-0"26'-0"4'-0" <br />(E) MAIN HOUSE <br />(E) LAWN <br />(E) LAWN <br />CL <br />PATIO <br />COVER <br />PATIO <br />COVER <br />(N) SOLAR MODULES <br />(N) MICRO-INVERTERS <br />(N) JUCTION BOX <br />(E) GUEST ROOM <br />315 E Stanford St - <br />201817961/30/2024