ASCE 30.3.2 Design Wind Pressure Beam/ Top Chord Check <br />Roof Slope =2 ° <br />Roof Shape MonoSlope <br />Tributary Width s =2.00 ft <br />Tributary Length L =30.00 ft <br />Effective Area A = L ( MAX [ s , L/3] )=100 f 2 <br />Height of Structure h =15 ft <br />Wind Speed V =95 mph <br />Exposure Categor C <br />Building Width B =25 ft <br />Building Length L =30 ft <br />Zone Width a =3 ft <br />Elevation Height zg =77 ft <br />Wind Directionality Kd =0.85 <br />Topography Factor Kt =1.00 <br />Ground Elevation Factor Ke =1.00 <br />Velocity Pressure Exposure Coefficient Kz =0.85 <br />Velocity Pressure qz = 0.00256KzKztKdKeV2 =16.62 psf <br />Internal Pressure Coefficient (GCpi)=-0.18 <br />Zone GCp p = qz [(GCp) - (Gcpi)] <br />3 1.60 -29.59 <br />3r - - <br />3e - - <br />2 1.50 -27.93 <br />2r - - <br />2e - - <br />2n - - <br />1 1.10 -21.28 <br />1' - - <br />315 E Stanford St - <br />201817961/30/2024