Laserfiche WebLink
3' <br />3'3' <br />3' <br />3' <br />3' <br />3' <br />3' <br />N <br />SCALE: 1/16" = 1'-0" <br />PV SYSTEM SITE PLAN <br />PV SYSTEM SIZE: <br />7.79 kW DC <br /> LEGEND <br />CONSTRUCTION NOTESLOCATION OF METER MAIN COMBO, <br />MOUNTED ON EXTERIOR WALL OF A <br />SINGLE FAMILY RESIDENCE. <br />NEW SOLAR PANELS <br />(19) SOLAREVER SE-182*91-410M-108 (410W) <br />WITH (10) AP SYSTEM DS3-L MICROINVERTERS <br />MOUNTED TO THE BACK OF MODULES MOUNTED <br />ON COMP SHINGLE ROOF <br />29 <br />6 <br />0 <br /> <br />S <br /> <br />G <br />R <br />E <br />E <br />N <br />V <br />I <br />L <br />L <br />E <br /> <br />S <br />T <br />UN <br />I <br />T <br /> <br />B <br />ROOF OBSTRUCTIONS <br />SHEET <br />CONTRACTOR <br />SOLGEN CONSTRUCTION LLC. <br /> 2960 S GREENVILLE ST <br />UNIT B, <br /> SANTA ANA, <br /> CA 92704 <br /> APN:93307090 <br /> DATE:4/26/2023 <br />PIZANO <br />RESIDENCE <br />License#: C-10 1053344 <br />DESIGNER: OJS <br />CORE ENERGY GROUP. <br />ADDRESS: 2072 N MAIN ST <br />FL 2, LOGAN <br />UT 84341-1993 <br />CSLB#: 1053344 <br />PV-1 <br />Roof Azimuth: 270 ° <br />Roof Tilt: 18° <br />Roof Section 2 <br />LC LOAD CENTER <br />DRIVEWAY <br />LC <br />LOCATION OF "RAPID SHUTDOWN" <br />AC DISCONNECT CEC 690.12 <br />Roof Azimuth: 90° <br />Roof Tilt: 18° <br />Roof Section 1 <br />ACD AC DISCONNECT <br />M <br />M METER MAIN COMBO <br />CAL-FIRE ROOF LADDER <br />ACCESS POINT <br />CAL-FIRE ROOF LADDER <br />ACCESS POINT <br />1. SOLAR PHOTOVOLTAIC SYSTEM TO BE INSTALLED ON <br />RESIDENTIAL STRUCTURE. <br />2. THIS PROJECT HAS BEEN DESIGNED IN COMPLIANCE WITH <br />THE CBC SECTION 1609 TO WITHSTAND A BASIC WIND <br />SPEED OF 110 MPH (3 SECOND GUST), WIND EXPOSURE C. <br />3. THE ROOF MEMBERS ARE 2 "X 4" TRUSSES AT 24" ON <br />CENTER. CONNECTION TO STRUCTURE SHALL NOT BE <br />WITHIN 11" OF NAILING PLATES. <br />4. THE SOLAR PHOTOVOLTAIC INSTALLATION SHALL NOT <br />OBSTRUCT ANY PLUMBING, MECHANICAL, OR BUILDING <br />ROOF VENTS. <br />5. ALL CONDUCTORS AND CONDUITS MOUNTED ON ROOF <br />SHALL BE MINIMUM 7/8" ABOVE ROOF SURFACE <br />(INCLUDING CABLES UNDERNEATH MODULES AND <br />RACKING). <br />6. ROOF ACCESS POINTS SHALL BE PROVIDED PER THE <br />FOLLOWING (CRC R324.7.1, CBC 3111.2.1) <br />6.1. LOCATED IN AREAS NOT REQUIRING PLACEMENT OF <br />GROUND LADDERS OVER OPENINGS SUCH AS DOORS <br />OR WINDOWS. <br />6.2. LOCATED AT STRONG POINTS OF CONSTRUCTION IN <br />LOCATIONS WHERE ACCESS POINT DOES NOT <br />CONFLICT WITH OVERHEAD OBSTRUCTIONS SUCH AS: <br />TREES, WIRES, OR SIGNS. <br />7. SETBACKS AT RIDGES CAN BE REDUCED TO 18 INCHES IN <br />COMPLIANCE WITH 2022 CFC/2021 IFC 1205.2.1.2 <br />TOTAL PLAN VIEW AREA = 5013.8 SQFT <br />TOTAL PV AREA = 19(67.87 IN)(44.64 IN)/(144 IN^2) = 399.75 SQFT <br />=(399.75 SQFT/ 5013.8 SQFT)100 = 7.97% <br />TOTAL PV AREA FOR EXISTING SYSTEM <br />=17(65 IN)(39 IN)/(144 IN^2) = 299.27 SQFT <br />=(299.27 SQFT/ 5013.8 SQFT)100 =9.01% <br />AC <br />D <br />SS <br />P <br />CAL-FIRE ROOF LADDER <br />ACCESS POINT <br />PV INTERCONNECTION POINT. <br />LOCATION OF SUB SERIVCE <br />PANEL,LOAD CENTER & AC <br />DISCONNECT MOUNTED ON INTERIOR <br />WALL OF A SINGLE FAMILY <br />RESIDENCE. <br />2960 S Greenville <br />St Unit B - <br />2017942605/04/23