Laserfiche WebLink
COVER SHEET <br />PHOTOVOLTAIC ROOF MOUNT SYSTEM <br />306 W ALPINE AVE, SANTA ANA, CA, 92707 USA <br />SHEET NAME <br />SHEET NUMBER <br />PV-0 <br />PROJECT NAME <br />EU <br />G <br />E <br />N <br />I <br />O <br /> <br />S <br />A <br />N <br />C <br />H <br />E <br />Z <br />30 <br />6 <br /> <br />W <br /> <br />A <br />L <br />P <br />I <br />N <br />E <br /> <br />A <br />V <br />E <br />, <br />SA <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />, <br />C <br />A <br />, <br /> <br />9 <br />2 <br />7 <br />0 <br />7 <br /> <br />U <br />S <br />A <br />AP <br />N <br />: <br /> <br />4 <br />1 <br />0 <br />1 <br />6 <br />1 <br />3 <br />9 <br />UT <br />I <br />L <br />I <br />T <br />Y <br />: <br /> <br />S <br />C <br />E <br />AH <br />J <br />: <br /> <br />S <br />A <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br /> <br />C <br />I <br />T <br />Y <br />SHEET SIZE <br />ANSI B <br />11" X 17" <br />DEL MAR, CA 92014, USA <br />REVDATE DESCRIPTION <br />VERSION <br />UR10/22/2022 INITIAL RELEASE <br />GOVERNING CODES: <br />2019 CALIFORNIA ELECTRICAL CODE (CEC) <br />2019 CALIFORNIA BUILDING CODE (CBC) <br />2019 CALIFORNIA RESIDENTIAL CODE (CRC) <br />2019 CALIFORNIA GREEN CODE (CGC) <br />2019 CALIFORNIA MECHANICAL CODE (CMC) <br />2019 CALIFORNIA PLUMBING CODE (CPC) <br />2019 CA FIRE CODE TITLE 24 SUPPLEMENT <br />ANY OTHER LOCAL AMENDMENTS <br />2 VICINITY MAP <br />SCALE: NTSPV-0 <br />1 AERIAL PHOTO <br />SCALE: NTSPV-0 <br />GENERAL NOTES <br />· THE CONTRACTOR/INSTALLER OF THE SOLAR PV SYSTEM OVER EXISTING <br />ROOF SHALL CONFORM TO OSHA REQUIREMENTS DURING THE <br />CONSTRUCTION PHASE. JOB SAFETY AND CONSTRUCTION PROCEDURES <br />ARE THE SOLE RESPONSIBILITY OF THE CONTRACTOR/INSTALLER. <br />· REFER TO ELECTRICAL DRAWING PV-4 FOR PANEL DETAILED <br />INFORMATION. <br />· IN CASE OF CONFLICT BETWEEN STRUCTURAL DRAWINGS AND <br />ELECTRICAL DRAWINGS, THE MOST RIGID REQUIREMENTS SHALL <br />GOVERN. <br />· THE CONTRACTOR/INSTALLER SHALL VERIFY ALL EXISTING BUILDING <br />INFORMATION SHOWN (DIMENSIONS, ROOF TOP PROJECTIONS, ETC.) AND <br />NOTIFY THE ENGINEER OF ANY DISCREPANCIES PRIOR TO INSTALLATIONS <br />OF PV SYSTEM. <br />· THE CONTRACTOR/INSTALLER SHALL VERIFY AND COORDINATE EXISTING <br />OPENINGS, ROOF TOP UNITS, VENT PIPES, ETC. SHOWN ON DRAWINGS. IF <br />THERE IS A DISCREPANCY BETWEEN DRAWINGS, IT IS THE <br />CONTRACTORS/INSTALLER'S RESPONSIBILITY TO NOTIFY ENGINEER <br />PRIOR TO PERFORMING THE WORK. <br />· ALL CONSTRUCTION IS TO BE PERFORMED IN STRICT CONFORMANCE <br />WITH ALL APPLICABLE TOWN, COUNTY & STATE REGULATIONS AND/OR <br />ANY OTHER GOVERNING BODIES. <br />· DO NOT SCALE THESE DRAWINGS, USE DIMENSIONS. CONTRACTOR MUST <br />CONDUCT ROOF SURVEY TO VERIFY DIMENSIONS SHOWN ON PLAN PRIOR <br />TO INSTALLATION. IF THERE IS A DISCREPANCY IT IS <br />CONTRACTOR/INSTALLER'S RESPONSIBILITY TO NOTIFY THE ENGINEER <br />IMMEDIATELY. <br />· LOCATED IN AREAS NOT REQUIRING PLACEMENT OF GROUND LADDERS <br />OVER OPENINGS SUCH AS DOORS OR WINDOWS. <br />· LOCATED AT STRONG POINTS OF BUILDING CONSTRUCTION IN <br />LOCATIONS WHERE ACCESS POINT DOES NOT CONFLICT WITH <br />OVERHEAD OBSTRUCTIONS SUCH AS TREE LIMBS, WIRES, OR SIGNS. <br />· DISCONNECT MEANS MUST HAVE DEDICATED CLEAR UNOBSTRUCTED <br />WORKING SPACE NOT LESS THAN 3' DEEP BY 2.5' WIDE TO NOT LESS <br />THAN 6.5' ABOVE WALKABLE SURFACES IN FRONT OF DISTRIBUTION <br />PANEL. <br />· ALL SOLAR MODULES, EQUIPMENT, AND METALLIC COMPONENTS TO BE <br />BONDED. <br />· PV ARRAY NOT TO EXCEED HIGHEST POINT OF THE ROOF. <br />· RAPID SHUTDOWN IS ACTIVED AT THE INVERTER BY THE AC DISCONNECT. <br />ELECTRICAL NOTES <br />· ALL EQUIPMENT TO BE LISTED BY UL OR OTHER NRTL, AND LABELED FOR <br />ITS APPLICATION. <br />·ALL CONDUCTORS SHALL BE COPPER, RATED FOR 600 V AND 90 & 75 <br />DEGREE C WET ENVIRONMENT. <br />· WIRING, CONDUIT, AND RACEWAYS MOUNTED ON ROOFTOPS SHALL BE <br />ROUTED DIRECTLY TO, AND LOCATED AS CLOSE AS POSSIBLE TO THE <br />NEAREST RIDGE, HIP, OR VALLEY. <br />·WORKING CLEARANCES AROUND ALL NEW AND EXISTING ELECTRICAL <br />EQUIPMENT SHALL COMPLY WITH CEC 110.26. <br />·DRAWINGS INDICATE THE GENERAL ARRANGEMENT OF SYSTEMS. <br />CONTRACTOR SHALL FURNISH ALL NECESSARY OUTLETS, SUPPORTS, <br />FITTINGS AND ACCESSORIES TO FULFILL APPLICABLE CODES AND <br />STANDARDS. <br />·WHERE SIZES OF JUNCTION BOXES, RACEWAYS, AND CONDUITS ARE NOT <br />SPECIFIED, THE CONTRACTOR SHALL SIZE THEM ACCORDINGLY. <br />·ALL WIRE TERMINATIONS SHALL BE APPROPRIATELY LABELED AND <br />READILY VISIBLE. <br />·MODULE GROUNDING CLIPS TO BE INSTALLED BETWEEN MODULE FRAME <br />AND MODULE SUPPORT RAIL, PER THE GROUNDING CLIP <br />MANUFACTURER'S INSTRUCTION. <br />·MODULE SUPPORT RAIL TO BE BONDED TO CONTINUOUS COPPER E.G.C. <br />VIA WEEB LUG OR ILSCO GBL-4DBT LAY-IN LUG. <br />·THE POLARITY OF THE GROUNDED CONDUCTORS IS NEGATIVE <br />INTERCONNECTION METHOD : SUPPLY SIDE BREAKER PER NEC705.12(A) <br />MSP UPGRADE: YES <br />EXISTING MSP INFORMATION <br />(E)100A MAIN SERVICE PANEL WITH (E) 100A MAIN BREAKER <br />SYSTEM SUMMARY: <br />(N) 16 - HANWHA Q CELL Q.PEAK DUO BLK ML-G10+ (400W) MODULES <br />(N) 16 - ENPHASE ENERGY IQ8M-72-2-US MICRO-INVERTERS <br />(N) JUNCTION BOX <br />(N) 200A MAIN SERVICE PANEL (MC2040B1200EFC SOLAR READY) <br /> WITH (N) 200A MAIN BREAKER <br />(N) ENPHASE IQ COMBINER BOX 4 <br />ROOF TYPE: - ROLLED COMP <br />ROOF FRAME: - 2"X8" RAFTERS @16" O.C. <br />STORY: - TWO STORY <br />SNOW LOAD : - 0 PSF <br />WIND SPEED :- 95 MPH <br />WIND EXPOSURE:- C <br />RISK CATEGORY:- II <br />COORDINATE:- 33.700261, -117.870484 <br />DESIGN CRITERIA: <br />16 MODULES-ROOF MOUNTED - 6.40 kWDC, 5.766 CEC kWAC <br />SHEET INDEX <br />PV-0 COVER SHEET <br />PV-1 SITE PLAN WITH ROOF PLAN <br />PV-2 ROOF PLAN WITH MODULES <br />PV-3 ATTACHMENT DETAILS <br />PV-4 ELECTRICAL LINE DIAGRAM WITH <br />CALCULATION <br />PV-5 WARNING LABELS & PLACARD <br />PV-6+ EQUIPMENT SPEC SHEETS <br />11 Nov 2022 <br />EXP : 30 Sep 2023 <br />STRUCTURAL ONLY <br />Bldg permit #101113164 <br />Elect permit #20178231 <br />Permits issued on 12/20/22 <br />306 W Alpine Ave <br />12/27/22