Project : <br />Project Number: <br />By : <br />Date : <br />Eugenio Sanchez <br />PE <br />25-10-2022 <br />Check for Increase in overall seismic loads <br />Array Area = ft2 <br />Number of Arrays = <br />Total Array Area = ft2 <br />Array Load = psf <br />Number of Existing Arrays = <br />Exisitng Area = ft2 <br />Total Array Wt. = lb <br />Total Roof Area = ft2 <br />DL of Roof = psf <br />Total Wt of Roof = lb <br />Increase in Seismic Wt = < <br />12.31 <br />33593 <br />3.0% 10% <br />Conservativelsy the Wt. of the Walls tributary to the roof is not included. Seismic weight increase is less <br />thaan 10% and no seismic retrofit or evaluation of existing lateral system is required per Section 503.4 of <br />2019 CEBC. <br />21.1 <br />16 <br />337.93 <br />2728.2 <br />3.00 <br />1013.8 <br />0 <br />0.00 <br />306 W Alpine Ave <br />12/27/22