Laserfiche WebLink
~96.34' <br />~3 <br />1 <br />. <br />4 <br />9 <br />' <br />~96.34' <br />~3 <br />1 <br />. <br />4 <br />9 <br />' <br />15'-0" <br />42'-0" 5' <br />- <br />0 <br />" <br />JB <br />MS <br />P <br />CB <br />AC <br />D <br />UM <br />JB <br />MSP CBACD <br />UM <br />SITE PLAN WITH ROOF PLAN <br />SHEET NAME <br />SHEET NUMBER <br />PV-1 <br />PROJECT NAME <br />J <br />E <br />S <br />U <br />S <br /> <br />H <br />U <br />E <br />R <br />T <br />A <br />29 <br />1 <br />0 <br /> <br />B <br />R <br />A <br />D <br />F <br />O <br />R <br />D <br /> <br />P <br />L <br />. <br /> <br />A <br />P <br />T <br /> <br />A <br />, <br />SA <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />, <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />7 <br /> <br />U <br />S <br />A <br />AP <br />N <br /># <br /> <br />9 <br />3 <br />3 <br />1 <br />2 <br />0 <br />7 <br />3 <br />UT <br />I <br />L <br />I <br />T <br />Y <br />: <br /> <br />S <br />C <br />E <br />AH <br />J <br />: <br /> <br />C <br />I <br />T <br />Y <br /> <br />O <br />F <br /> <br />S <br />A <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />SHEET SIZE <br />ANSI B <br />11" X 17" <br />DEL MAR, CA 92014, USA <br />REVDATE DESCRIPTION <br />VERSION <br />UR09/14/2022 INITIAL RELEASE <br />SITE PLAN WITH <br />ROOF PLAN <br />1 SCALE: 3/32" = 1'-0" <br />NOTE: <br />A. ALL ELECTRICAL EQUIPMENT, INVERTERS, <br />DISCONNECTS, MAIN SERVICE PANELS, ETC. SHALL <br />NOT BE INSTALLED WITHIN 3’ OF THE GAS METERS’ <br />SUPPLY OR DEMAND PIPING. <br /> ROOF ACCESS POINT SHALL BE LOCATED IN AREAS THAT DO NOT REQUIRE <br />THE PLACEMENT OF GROUND LADDERS OVER OPENINGS SUCH AS WINDOWS <br />OR DOORS, AND LOCATED AT STRONG POINTS OF BUILDING CONSTRUCTION IN <br />LOCATIONS WHERE THE ACCESS POINT DOES NOT CONFLICT WITH OVERHEAD <br />OBSTRUCTIONS SUCH AS TREE LIMBS, WIRES OR SIGNS. <br />LEGEND <br />UTILITY METER <br />AC DISCONNECT <br />JUNCTION BOX <br />UM <br />ACD <br />JB <br />MSP MAIN SERVICE PANEL <br />ENPHASE IQ COMBINER 4CB <br />GATE <br />FENCE <br />PROPERTY LINE <br />TREES <br />BR <br />A <br />D <br />F <br />O <br />R <br />D <br /> <br />P <br />L <br />. <br /> <br />A <br />P <br />T <br /> <br />A <br />W DYER RD <br />TWO- STORY <br />HOUSE <br />EX <br />I <br />S <br />T <br />I <br />N <br />G <br />DR <br />I <br />V <br />E <br />W <br />A <br />Y <br />GARAGE3DWLR&RYHU <br />STAMPED 02/07/2023 <br />STRUCTURAL NOTES : <br />1.THESE PLANS ARE STAMPED FOR STRUCTURAL CODE COMPLIANCE OF THE ROOF FRAMING SUPPORTING THE <br />PROPOSED PV INSTALLATION ONLY. <br />2. THESE PLANS ARE NOT STAMPED FOR WATER LEAKAGE. <br />3. PV MODULES, RACKING, AND ATTACHMENT COMPONENTS MUST FOLLOW MANUFACTURER GUIDELINES AND <br />REQUIREMENTS. <br />4. PLEASE SEE THE ACCOMPANYING STRUCTURAL CALCULATIONS REPORT FOR ADDITIONAL INFORMATION. <br />5. PRIOR TO COMMENCEMENT OF WORK, THE SOLAR INSTALLER SHALL VERIFY THE ROOF FRAMING INFO BEFORE <br />INSTALLATION AND NOTIFY THE E.O.R. IF THERE IS ANY INCONSISTENCY BETWEEN SITE VERIFICATION AND <br />FOLLOWING: 2x4 TRUSSES @ 24" OC SPACING WITH MAX UNSUPPORTED SPAN EQUAL OR LESS THAN 8 FT. <br />2910 S Bradford Pl <br />#A (Townhome)03/10/23