Laserfiche WebLink
97% <br />0.97 <br />1.21 <br />1.21 <br />25 IQ8PLUS-72-2-US (CEC) <br />FROM JBOX TO IQ COMBINER BOX <br />FROM IQ COMBINER BOX TO MAIN SERVICE PANEL <br />3 1/2'' <br />0.71 TEMP. DERATE FACTOR (TEMP - 39 + 17 = 56C) <br /> RACEWAY HEIGHT FROM ROOF <br />PV SYSTEM <br />AS INDICATED <br />NOVEMBER 08, 2022 <br />CAROL TOPPING <br />3317 S TIMBER ST <br />SANTA ANA, CA 92707 <br />Current Insight, LLC <br />2852 W. Amini Way <br />South Jordan, UT <br />84095 <br />EXO ENERGY <br />Address: <br />1247 Simpson Way <br />Escondido, CA 92029 <br />Phone Number: <br />208-351-4153 <br />CSLB:#1063308 <br />Drafted By: <br />CONTRACTOR <br />3 <br />WIRE SIZE <br />CALCULATIONSFROM PV MODULES TO JBOX <br /> #12 AWG Q-CABLE, PV WIRE(4) 1 <br />(1) #6 AWG BARE CU EGC <br />2 <br /> #8 AWG CU EGC, <br />(3) <br />3 <br />(1) #8 AWG CU EGC, <br /> MAXIMUM INVERTER OUTPUT CURRENT <br /> WALL TEMPERATURE FACTOR <br />OUTPUT CALCULATIONS <br />PV SYSTEM MAX DC OUTPUT <br />PV SYSTEM MAX AC OUTPUT <br />1.25 <br />0.91 <br />(4) <br />(1) <br />25 <br /> Pmax (PTC Rating) <br />3/4'' EMT TYPE CONDUIT <br />3/4'' EMT TYPE CONDUIT <br />#10 AWG THWN-2 <br />WIRE CHART WIRE CHART <br />a b <br />2 BRANCH CIRCUITS <br /> INVERTER OUTPUT MAX CURRENT <br /> COEFFICIENT 1.25 <br />13 <br /> BRANCH CIRCUIT CURRENT a: 13 BREAKER SIZE PER BRANCH CRCT <br />20A <br />0.8ADJST. FACTOR (4 thru 6 WIRES) <br />**1.25131.21 19.7A <br /> ADJUSTED CONDUCTOR AMPACITY <br />/ / 19.7 0.71 0.8 34.7A <br /> NUMBER OF MICROINVERTERS <br /> 10.00KW <br />9.01KW <br />MAIN SERVICE PANEL RATING <br />BUSBAR RATING <br />MAIN BREAKER <br />PV BACKFEED BREAKER SIZE <br />120% RULE: <br />MAX ALLOWED FEED <br />40A <br />125A <br />225A <br />270A <br />125A''MB'' + 40A "SOLAR" = 165A ≤ 270A MAX <br />WIRE CHART <br />QTY <br /> CONSIDER CONTINUOUS COEFFICIENT <br /> CONSIDER CONTINUOUS (A)1.25**25 1.21 37.8 <br />*1.25 / 0.91*25 1.21 41.6 <br /> #8 AWG THWN-2 <br /> TEMPERATURE ADJUSTMENT (A) <br />25 <br />Attention!!!!!!! <br />Need Calculation <br />(don't delete this note) <br />25 <br />25 <br />400W <br />* 400 <br />371.5W <br />* 371.5 * <br />Q.PEAK DUO BLK ML-G10+ 400 <br />12 <br /> BRANCH CIRCUIT CURRENT b: 12 BREAKER SIZE PER BRANCH CRCT <br />20A**1.25121.21 18.2A <br />3317 S Timber St <br />12/06/22