My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3317 S Timber St - Plan
PBA
>
Building
>
ProjectDox
>
T
>
Timber St
>
3317 S Timber St
>
3317 S Timber St - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/1/2025 12:07:01 PM
Creation date
6/1/2025 12:06:49 PM
Metadata
Fields
Template:
Plan
Permit Number
20178110
101112992
Full Address
3317 S Timber St
Document Relationships
101112992 - Permit
(Permit - Plan)
Path:
\Building\Permits\T\Timber St\3317 S Timber St
20178110 - Permit
(Permit - Plan)
Path:
\Building\Permits\T\Timber St\3317 S Timber St
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
28
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
ATTACHMENT <br />LAYOUT <br />5 <br />PV SYSTEM <br />AS INDICATED <br />NOVEMBER 08, 2022 <br />CAROL TOPPING <br />3317 S TIMBER ST <br />SANTA ANA, CA 92707 <br />Current Insight, LLC <br />2852 W. Amini Way <br />South Jordan, UT <br />84095 <br />EXO ENERGY <br />Address: <br />1247 Simpson Way <br />Escondido, CA 92029 <br />Phone Number: <br />208-351-4153 <br />CSLB:#1063308 <br />Drafted By: <br />CONTRACTOR <br />STRUCTURAL STAMPROOF <br />PITCH <br />ROOFING <br />TYPE <br />ATTACHMENT <br />TYPE <br />FRAMING <br />TYPE <br />FRAMING <br />SIZE <br />PENETRATION <br />PATTERN <br />23° <br />RACKING <br />TYPE <br />MAX <br />PENETRATION <br />SPACING <br />ROOFING <br />LAYERS <br />WIND SPEED 110 MPH EXPOSURE C <br />LAG BOLTS MOUNTS AND MOUNTING HARDWARE WILL BE <br />SEALED WITH CHEM LINK SEALANT OR EQUIVALENT. <br />MODULE WEIGHT (LBS) <br /># OF MODULES <br />TOTAL MODULE WEIGHT (LBS) <br />RACK WEIGHT (LBS) <br />TOTAL SYSTEM WEIGHT (LBS) <br /># OF STANDOFFS <br />LOADING PER STANDOFF (LBS) <br />TOTAL MODULE AREA (SQ.FT.) <br />LOADING (PSF) <br />WEIGHT LOAD CALCULATION INDEX <br />ROOF SHEATHED WITH 1/2" PLYWOOD AND UPPER <br />SURFACE IS FACED WITH FELT PAPER <br />TOTAL ROOF AREA (Sq. FT) <br />% OF COVERED AREA <br />PV MODULE MODEL # <br />MICROINVERTER WEIGHT (LBS) <br />25 <br />Roof 1 Layer Flat Concrete Tile EcoFasten Truss Staggered 48"2"X4" @ 24" O.C <br />MIN 2.5" EMBEDMENT <br />RACKING RAIL <br />ATTACHMENT <br />ROOF FRAMING <br />Ecofasten Tile Hook Flashing <br />5/16" X 4.0" <br />ATTACHMENT DETAILS <br />ROOF SHEETING <br />WATERPROOF <br />MEMBRAIN ROOF TILE <br />SOLAR MODULE <br />ECOFASTEN'S <br />CLICKFIT TILE HOOK <br />ECOFASTEN RAIL <br />TILE HOOK FLASHING <br />5/16"x4.0" LAG BOLT <br />WITH 2 1/2"MIN <br />THREAS PENETRATION <br />2''X6'' Blocking <br />SOLAR MODULE <br />ROOF <br />ASCE 7-16 <br />Max 3.5'' 48.5 <br />Q.PEAK DUO BLK ML-G10+ 400 <br />55 <br />525 <br />1965 <br />1213 <br />243 <br />60 <br />1515 <br />27.5 <br />2.88 <br />26.7 <br />48'' 24'' <br />11/16/2022 <br />3317 S Timber St <br />12/06/22
The URL can be used to link to this page
Your browser does not support the video tag.