Laserfiche WebLink
Table of Contents <br />Parameters 2 <br />Components and Specifications 3 <br />Loads and Distributions 8 <br />Basic Load Combinations 11 <br />Longitudinal Analysis 12 <br />Column & Backer Analysis 13 <br />Beam Analysis 15 <br />Beam to Column Analysis 18 <br />Bracing Analysis 19 <br />Anchor Analysis 21 <br />Overturning Analysis 24 <br />Baseplate Analysis 25 <br />Slab and Soil Analysis 27 <br />Scope: <br />This storage system analysis is intended to determine its compliance with appropriate building codes <br />with respect to static and seismic forces. <br />The storage racks are prefabricated and are to be field assembled only, with no field welding. <br />PROJECT: <br />FOR: <br />ADDRESS: <br />SHEET#: <br />CALCULATED BY: <br />DATE: <br />Pace Supply <br />The Beacon Group_Kevin <br />3421 W. Segerstro <br />Santa Ana, CA <br />1 <br />tchang <br />6/20/2023 <br />TEL:(909)869-0989 <br />1130 E. CYPRESS ST, COVINA, CA 91724 <br />PN:20230619_19 <br />Cantilever Racks --------------------------------------------------------------------------------28 to 41 <br />Shelving ----------------------------------------------------------------------------------------- 42 to 50 <br />3421 W Segerstrom Ave - <br />10111647610/31/2023